Endress+Hauser 5P1B Proline Promag P100 Electromagnetic Flowmeter

: В наличии

: Flow Measurement

: Endress+Hauser

Обычная цена Распродажа

OverviewEndress+Hauser Proline Promag P100 Electromagnetic Flowmeter,  it is a flowmeter for highest medium temperatures with an ultra-compact transmitter.Specs at a glanceMax. measurement error Volume flow (standard): ±0.5 %...

Overview

Endress+Hauser Proline Promag P100 Electromagnetic Flowmeter,  it is a flowmeter for highest medium temperatures with an ultra-compact transmitter.

Specs at a glance

Max. measurement error Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s Measuring range 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min) Medium temperature range Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) Max. process pressure PN 40, Class 300, 20K Wetted materials Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Duplex 1.4462 (UNS S31803)

Application

Promag P is dedicated to chemical and process applications with corrosive liquids and high medium temperatures. Its ultra-compact transmitter delivers full performance on the smallest footprint and enables seamless system integration, making Promag P 100 the preferred choice for skid builders, equipment manufacturers and system integrators. Heartbeat Technology enables compliance and process safety at all times.

* The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
* Dedicated to chemical and process applications with corrosive liquids and high medium temperatures


Device properties
* Nominal diameter: max. DN 600 (24")
* All common Ex approvals
* Liner made of PTFE or PFA
* Robust, ultra-compact transmitter housing
* Local display available 
 

Benefits

* Versatile applications – wide variety of wetted materials
* Energy-saving flow measurement – no pressure loss due to cross-section constriction
* Maintenance-free – no moving parts
* Space-saving transmitter – full functionality on the smallest footprint
* Time-saving local operation without additional software and hardware – integrated web server
* Integrated verification – Heartbeat Technology

Specification

Measuring principle Electromagnetic
Product headline The flowmeter for highest medium temperatures with an ultra-compact transmitter.
Dedicated to chemical and process applications with corrosive liquids and high medium temperatures.
Sensor features Diverse applications – wide variety of wetted materials. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
Nominal diameter: max. DN 600 (24"). All common Ex approvals. Liner made of PTFE or PFA.
Transmitter features Space‐saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology.
Robust, ultra-compact transmitter housing. Local display available.
Nominal diameter range DN 15 to 600 (½ to 24")
Wetted materials Liner: PFA, PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum; Titanium
Duplex 1.4462 (UNS S31803)
Measured variables Volume flow, conductivity, mass flow, corrected volume flow, corrected conductivity
Max. measurement error Volume flow (standard): ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s
Measuring range 4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
Max. process pressure PN 40, Class 300, 20K
Medium temperature range Liner material PFA: –20 to +150 °C (–4 to +302 °F)
Liner material PFA high‐temperature: –20 to +180 °C (–4 to +356 °F)
Liner material PTFE: –40 to +130 °C (–40 to +266 °F) 
 
Ambient temperature range Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Sensor housing material DN 15 to 300 (½ to 12"): AlSi10Mg, coated
DN 350 to 600 (14 to 24"): Carbon steel with protective varnish
Transmitter housing material AlSi10Mg, coated
Degree of protection IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs 4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, PROFIBUS DP, Modbus RS485, EtherNet/IP, PROFINET
Power supply DC 20 to 30 V
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO
Other approvals and certificates  
Product safety CE, C-Tick
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)
Marine approvals and certificates LR approval, DNV approval, ABS approval, BV approval
Pressure approvals and certificates PED, CRN
Material certificates 3.1 material
Hygienic approvals and certificates Drinking water approval: ACS, NSF 61, WRAS

 

пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки

Обычно мы отправляем по DHL, UPS, FEDEX или TNT,

В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.