Overview
Endress+Hauser 8H1B Proline Promass H100 Coriolis Flowmeter is a chemically resistant single-tube flowmeter with an ultra-compact transmitter.
Specs at a glance
* Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas, Tantalum only): ±0.5 %
Density (liquid): ±0.0005 g/cm³
* Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
* Medium temperature range
Tantalum: –50 to +150 °C (–58 to +302 °F)
Zirconium: –50 to +205 °C (–58 to +401 °F)
* Max. process pressure
PN 40, Class 300, 20K
* Wetted materials
Measuring tube: Tantalum 2.5W; 702 (UNS R60702)
Connection: Tantalum; 702 (UNS R60702)
Field of application
The chemically resistant single-tube design of the Promass H is destined for applications requiring highest corrosion resistance.Combined with the smallest transmitter housing available today it delivers full performance on the smallest footprint. Designed for applications where space is a premium, Promass H 100 will be the preferred choice for system integrators, skid builders and equipment manufacturers.
* Measuring principle operates independently of physical fluid properties such as viscosity or density.
* Highly accurate measurement of liquids and gases in applications requiring highest corrosion resistance.
Device properties
* Measuring tube made of Tantalum, Zirconium
* Nominal diameter: DN 8 to 50 (3/8 to 2")
* Medium temperature up to +205 °C (+401 °F)
* Robust, ultra-compact transmitter housing
* High ingress protection: IP69K
* Local display available
Benefits
* Maximum safety for chemically aggressive fluids – corrosion-resistant wetted parts
* Fewer process measuring points – multivariable measurement (flow, density, temperature)
* Space-saving installation – no in/outlet run needs
* Space-saving transmitter – full functionality on the smallest footprint
* Time-saving local operation without additional software and hardware – integrated web server
* Integrated verification – Heartbeat Technology
Specification
item | value |
Warranty | 1 Year |
Customized support | OEM |
Place of Origin | Switzerland |
Brand Name | Endress+Hauser |
Model Number | Promass H100 |
Type | Coriolis meters, Coriolis flowmeter |
Measuring Principle |
Coriolis |
Product Headline | Chemically resistant single-tube flowmeter with an ultra-compact transmitter. Measuring highly accurately liquids and gases in applications requiring highest corrosion resistance. |
Sensor Features | Maximum safety for chemically aggressive fluids – corrosion‐resistant wetted parts. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Measuring tube made of Tantalum, Zirconium. Nominal diameter: DN 8 to 50 (³⁄₈ to 2"). Medium temperature up to +205 °C (+401 °F). |
Transmitter Features |
Space-saving transmitter – full functionality on the smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra-compact transmitter housing. Highest degree of protection: IP69. Local display available. |
Nominal Diameter Range |
DN 8 to 50 (³⁄₈ to 2") |
Wetted Materials | Measuring tube: Tantalum 2.5W; 702 (UNS R60702) Connection: Tantalum; 702 (UNS R60702) |
Measured Variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. Measurement Error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas, Tantalum only): ±0.5 % Density (liquid): ±0.0005 g/cm³ |
Measuring Range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. Process Pressure | PN 40, Class 300, 20K |
Medium Temperature Range | Tantalum: –50 to +150 °C (–58 to +302 °F) Zirconium: –50 to +205 °C (–58 to +401 °F) |
Ambient Temperature Range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor Housing Material | 1.4301 (304), corrosion resistant |
Transmitter Housing Material | Compact: AlSi10Mg, coated Compact/ultra‐compact: 1.4301 (304) |
Degree Of Protection | Standard: IP66/67, type 4X enclosure Option: IP69 |
Display/Operation | 4‐line backlit display available (no local operation) Configuration via web browser and operating tools possible |
Outputs | 4‐20 mA HART (active) Pulse/frequency/switch output (passive) |
Inputs | None |
Digital Communication | HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET |
Power Supply | DC 20 to 30 V |
Hazardous Area Approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC |
Product Safety | CE, C-Tick, EAC marking |
Metrological Approvals And Certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for traceable verification cording to ISO 9001:2008 – Section 7.6a (TÜV SÜD attestation) |
Marine Approvals And Certificates | PED, CRN |
Material Certificates | 3.1 material |
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,