Overview
For high temperature and high pressure applications in the oil & gas, chemical and power industry.
Specs at a glance
* Accuracy
Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):+/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)
* Process temperature
XT: -196...+280 °C(-321...+536 °F)
HT: -196...+450 °C(-321...+842 °F)
Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft):+/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft):+/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in)
* Process temperature
XT: -196...+280 °C(-321...+536 °F)
HT: -196...+450 °C(-321...+842 °F)
* Process pressure / max. overpressure limit
Vacuum...400 bar (Vacuum...5800 psi)
* Max. measurement distance
Rod:10 m (33 ft) Min DK>1.6
Rope:25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK >1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4
* Main wetted parts
Rod probe:304, 316L, Alloy C, Ceramic
Rope probe:304, 316, 316L, Alloy C, Ceramic
Coaxial probe:304, 316L, Alloy C, Ceramic
Vacuum...400 bar (Vacuum...5800 psi)
* Max. measurement distance
Rod:10 m (33 ft) Min DK>1.6
Rope:25 m...30 m (82 ft...98 ft) Min DK>1.6;
30 m...45 m (98 ft...148 ft) Min DK >1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4
* Main wetted parts
Rod probe:304, 316L, Alloy C, Ceramic
Rope probe:304, 316, 316L, Alloy C, Ceramic
Coaxial probe:304, 316L, Alloy C, Ceramic
Field of application
Levelflex FMP54 for continuous level measurement in liquids under extreme conditions. The process connection with its ceramic-graphite seal safeguards high temperature and high pressure applications as they occur in steam boilers and toxic media like ammonia. The gas tight feedthrough guarantees additional safety. Only the gas phase compensation of the FMP54 gives reliable results in case of gas and steam phases. Reliable measurement in case of moving surface and foam or in changing medias.
Version with rod or rope probe.
* Process connections: Thread or flange
* Temperature: -196 to +450°C (-320 to +842°F)
* Pressure: -1 to +400bar (-14.5 to +5,800psi)
* Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
* Accuracy: rod ±2mm (0.08")
* International explosion protection certificates, overfill prevention WHG, SIL, marine approval, steam boiler approval, 5-point linearity protocol
Version with rod or rope probe.
* Process connections: Thread or flange
* Temperature: -196 to +450°C (-320 to +842°F)
* Pressure: -1 to +400bar (-14.5 to +5,800psi)
* Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
* Accuracy: rod ±2mm (0.08")
* International explosion protection certificates, overfill prevention WHG, SIL, marine approval, steam boiler approval, 5-point linearity protocol
Benefits
* Reliable measurement even for changing product and process conditions
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Highest reliability due to new Multi-Echo Tracking evaluation
* Hardware and software developed according to IEC 61508 up to SIL3
* Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
* Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the
control system)
* World's easiest proof test for SIL and WHG saves time and costs
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Highest reliability due to new Multi-Echo Tracking evaluation
* Hardware and software developed according to IEC 61508 up to SIL3
* Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
* Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the
control system)
* World's easiest proof test for SIL and WHG saves time and costs
Specification
Measuring Principle
|
Guided radar
|
Characteristic / Application
|
Premium device high pressure/ high temperature
Rod probe, Rope probe, Coaxial Probe Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias |
Interface measurement
|
Clean interfaces liquid/ liquid;
Simultaneous measurement of interface and overall level |
Specialities
|
Heartbeat Technology,
Bluetooth® commissioning, Operation and maintenance SmartBlue App, HistoROM, RFID TAG for easy identification |
Supply / Communication
|
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART) Bluetooth® wireless technology and App (optional) |
Accuracy
|
Rod probe: +/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in) Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in) Coaxial probe: +/- 2 mm (0.08 in) |
Ambient temperature
|
-50...+80 °C
(-58...+176 °F) |
Process temperature
|
XT: -196...+280 °C
(-321...+536 °F) HT: -196...+450 °C (-321...+842 °F) |
Process pressure / max. overpressure limit
|
Vacuum...400 bar
(Vacuum...5800 psi) |
Main wetted parts
|
Rod probe:
304, 316L, Alloy C, Ceramic Rope probe: 304, 316, 316L, Alloy C, Ceramic Coaxial probe: 304, 316L, Alloy C, Ceramic |
Process connection
|
Thread:
G 1 1/2, MNPT 1 1/2 Flange: ASME 2"...4", DN50...DN100, JIS 10K, 63K, Fisher Masoneilan |
Sensor length
|
Rod probe: 10 m (33 ft)
Rope probe: 45 m (148 ft) Coaxial probe: 6 m (20 ft) |
Max. measurement distance
|
Rod:
10 m (33 ft) Min DK>1.6 Rope: 25 m...30 m (82 ft...98 ft) Min DK>1.6; 30 m...45 m (98 ft...148 ft) Min DK >1,9 Coaxial probe: 6 m (20 ft) Min DK>1.4 |
Communication
|
4...20 mA HART
PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology |
Certificates / Approvals
|
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, JPN Ex, UK Ex
|
Safety Approvals
|
Overfill protection WHG
SIL |
Design Approvals
|
EN 10204-3.1
NACE MR0175, MR0103 ASME B31.1, B31.3 AD2000 Steam boiler approval |
Marine approval
|
GL/ DNV/ ABS/ LR/ BV
|
Options
|
Sensor remote with 3 m/ 9 ft cable,
Remote operation via SmartBlue App using Bluetooth® |
please contact email for more about the shipping cost
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.