Endress + Hauser Cerabar PMP71B Pressure Transmitter

: In stock

: Pressure Measurement

: Endress+Hauser

Regular price Sale

Overview   * Standard:up to 0.05 %   Platinum:up to 0.025 % * Process temperature Standard : -40°C…+125°C (-40°F…+257°F)    Diaphragm seal:-40°C...+400°C  (-40°F...+752°F) * Pressure measuring range:400 mbar...700 bar (1.5 psi...10,500 psi) *...

Overview 

 * Standard:up to 0.05 %   Platinum:up to 0.025 %
 * Process temperature Standard : -40°C…+125°C (-40°F…+257°F)
    Diaphragm seal:-40°C...+400°C  (-40°F...+752°F)
 * Pressure measuring range:400 mbar...700 bar (1.5 psi...10,500 psi)
 * Main wetted parts:316L, AlloyC,Tantal, Monel,PTFE, Gold
 * Material process membrane:316L, AlloyC,Tantal, Monel,PTFE,Gold
 * Measuring cell :400 mbar...700 bar (6 psi...10,500 psi)

Benefits

 * With Heartbeat Technology you are able to verify the health of the device while the process is running.
* Simple indication of device status - display changes from green to red when diagnostic messages occur
* Reduce systematic failures - error free SIL commissioning and instrument guided proof testing
* Wireless control of the device in the process area with the SmartBlue App

Application

This transmitter belongs to the new Cerabar generation. The transmitter is robust and can be remotely controlled via app on a mobile device using a secure Bluetooth connection.The software is designed to simplify the handling. Intuitive wizards guide the user through setup, proof tests and verification of the device.
Heartbeat Technology offers verification and monitoring functions to detect unwanted anomalies e.g. changes in loop characteristics.

* Pressure measuring range: up to 700 bar (10500 psi)
* Process temperatures up to 400°C (752 °F) with diaphragm seal
* Accuracy: up to +/- 0.025%

Specification 

Measuring principle
Absolute and gauge pressure
Characteristic
Pressure transmitter with metallic process diaphragm.
Available with diaphragm seals.
Device health verification without process interruptions.
Intuitive and clear wizards for commissioning, proof tests and verification.
Supply voltage
4...20 mA HART
Ex d, Ex e, non-Ex:
10.5...35V DC :
Ex i: 10.5...30V DC
Reference Accuracy
Standard:
up to 0.05 %
Platinum:
up to 0.025 %
Long term stability
0.05 % of URL/ year
0.07 % of URL/ 5 years
0.10 % of URL/ 10 years
Process temperature
Standard:
-40°C…+125°C
(-40°F…+257°F)
Diaphragm seal:
-70°C...+400°C
(-94°F...+752°F)
Ambient temperature
-60°C...+80°C
(-76°F...+185°F)
Measuring cell
400 mbar...700 bar
(6 psi...10,500 psi)
Smallest calibratable span
5 mbar (0.075 psi)
Vacuum resistance
5 mbar (0.725 psi)
Max. Turn down
100:1
Max. overpressure limit
2,800 bar (40,600 psi)
Process connection
Thread:
G1/2...G2, R1/2, MNPT3/4...MNPT2,
FNPT1/2, R1/2
Flange:
DN25...DN100,
NPS 1"...4"
Pancake: 2"...4", DN50...DN100
Material process membrane
316L, AlloyC,
Tantal, Monel,
PTFE,
Gold
Material gasket
PTFE
Fill fluid
Silicone oil, Inert oil,
Vegetable oil,
High/ low temperature oil
Material housing
Aluminium,
316L
Communication
4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals
ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Safety approvals
SIL
Design approvals
EN10204-3.1,
NACE MR0103,
NACE MR0175
Marine approvals
Marine approvals
Drinking water approvals
NSF
Specialities
Heartbeat Technology,
Bluetooth® Operation and maintenance SmartBlue App,
LED Module,
RFID TAG for easy identification,
Plug and play functionalities,
HistoROM
please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.