Overview
Endress+Hauser Proline Promass P300 Coriolis Flowmeter. Specialist for life sciences with a compact, easily accessible transmitter.
Specs at a glance
* Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Density (liquid): ±0.0005 g/cm³
* Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
* Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F)
* Max. process pressure
PN 40, Class 150, 20K
* Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Application
Promass P is the specialist for sterile processes in the life sciences industry. It is dedicated to biotech applications requiring highest compliance with guidelines and regulations. With its compact transmitter Promass P 300 offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables compliance and process safety at all times.
* Measuring principle operates independently of physical fluid properties such as viscosity or density
* Dedicated to applications under sterile conditions in the life sciences industry
Device properties
* ASME BPE, 3-A and EHEDG conform & low delta ferrite
* Electropolished measuring tube in 1.4435 (316L)
* Fast recovery from CIP/SIP
* Compact dual-compartment housing with up to 3 I/Os
* Backlit display with touch control and WLAN access
* Remote display available
Benefits
* Highest process quality – fully compliant to industry requirements
* Fewer process measuring points – multivariable measurement (flow, density, temperature)
* Space-saving installation – no in-/outlet run needs
* Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology
Specification
item | value |
Warranty | 1 Year |
Customized support | OEM |
Place of Origin | Switzerland |
Brand Name | Endress+Hauser |
Model Number | Promass P300 |
Type | Coriolis meters, Coriolis flowmeter |
Measuring Principle |
Coriolis |
Product Headline | Specialist for life sciences with a compact, easily accessible transmitter. Dedicated to applications under sterile conditions in the life sciences industry. |
Sensor Features | Highest process quality – fully compliant to industry requirements. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. ASME BPE, 3‐A and EHEDG conform & low delta ferrite. Electropolished measuring tube in 1.4435 (316L). Fast recovery from CIP/SIP. |
Transmitter Features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact hygienic dual-compartment housing with IP69 and up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available. |
Nominal Diameter Range | DN 8 to 50 (⅜ to 2") |
Wetted Materials | Measuring tube: 1.4435 (316L) Connection: 1.4435 (316L); 1.4404 (316/316L) |
Measured Variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration |
Max. Measurement Error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Density (liquid): ±0.0005 g/cm³ |
Measuring Range | 0 to 70 000 kg/h (0 to 2570 lb/min) |
Max. Process Pressure | PN 40, Class 150, 20K |
Medium Temperature Range | Standard: –50 to +150 °C (–58 to +302 °F) Option: –50 to +205 °C (–58 to +401 °F) |
Ambient Temperature Range | Standard: –40 to +60 °C (–40 to +140 °F) Option: –50 to +60 °C (–58 to +140 °F) |
Sensor Housing Material | 1.4301 (304), corrosion resistant |
Transmitter Housing Material | AlSi10Mg, coated; stainless steel for hygenic transmitter design |
Degree Of Protection | IP66/67, type 4X enclosure IP69 |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available" |
Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital Communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA |
Power Supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous Area Approvals | ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, UK Ex, KC |
Product Safety | CE, C-tick, EAC marking |
Functional Safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological Approvals And Certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure Approvals And Certificates | PED, CRN |
Material Certificates | 3.1 material |
Hygienic Approvals And Certificates | 3-A, EHEDG, ASME BPE, ISPE, cGMP |