Overview
Endress+Hauser Proline Promag H200 Electromagnetic Flowmeter for smallest flow rates with genuine loop-powered technology
Specs at a glance
Max. measurement error Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s) Measuring range 0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min) Medium temperature range –20 to +150 °C (–4 to +302 °F) Max. process pressure PN 40, Class 150, 20K Wetted materials Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum
Application
Promag H is the preferred sensor for applications with highest requirements in the chemical and life sciences industries. With its genuine loop-powered technology, Promag H 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas thanks to its intrinsically safe design (Ex ia). Heartbeat Technology enables process safety at all times.
* The measuring principle is virtually independent of pressure, density, temperature and viscosity
* Dedicated to the measurement of the smallest flow quantities
Device properties
* Liner made of PFA
* Sensor housing made of stainless steel
* Various electrode materials available
* Loop-powered technology
* High ingress protection: IP69
* Plant safety: worldwide approvals (SIL, Haz. area)
Benefits
* Flexible installation concept – numerous hygienic process connections
* Energy-saving flow measurement – no pressure loss due to cross-section constriction
* Maintenance-free – no moving parts
* Convenient device wiring – separate connection compartment
* Safe operation – no need to open the device due to display with touch control, background lighting
* Integrated verification – Heartbeat Technology
Specification
Model Number | Proline Promag H 200 |
Measuring principle | Electromagnetic |
Product headline | Flowmeter for smallest flow rates with genuine loop-powered technology. Dedicated to the measurement of the smallest flow quantities. |
Sensor features | Flexible installation concept – numerous process connections. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts. Liner made of PFA. Sensor housing made of stainless steel. Various electrode materials available. |
Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). |
Nominal diameter range | DN 2 to 25 (¹⁄₁₂ to 1") |
Wetted materials | Liner: PFA Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone) Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum |
Measured variables | Volume flow, mass flow |
Max. measurement error | Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s) |
Measuring range | 0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min) |
Max. process pressure | PN 40, Class 150, 20K |
Medium temperature range | –20 to +150 °C (–4 to +302 °F) |
Ambient temperature range | –40 to +60 °C (–40 to +140 °F) |
Sensor housing material | 1.4301 (304), corrosion resistant |
Transmitter housing material | AlSi10Mg, coated |
Degree of protection | IP66/67, type 4X enclosure |
Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
Outputs | 4‐20 mA HART (passive) Pulse/frequency/switch output (passive) |
Inputs | None |
Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
Power supply | DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) |
Hazardous area approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC, JPN, UK Ex |
Product safety | CE, C-Tick |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure approvals and certificates | CRN |
Material certificates | 3.1 material |