Endress+Hauser 5H2B Proline Promag H200 Electromagnetic Flowmeter

: In stock

: Flow Measurement

: Endress+Hauser

Regular price Sale

OverviewEndress+Hauser Proline Promag H200 Electromagnetic Flowmeter for smallest flow rates with genuine loop-powered technologySpecs at a glanceMax. measurement error Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08...

Overview

Endress+Hauser Proline Promag H200 Electromagnetic Flowmeter for smallest flow rates with genuine loop-powered technology

Specs at a glance

Max. measurement error Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s) Measuring range 0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min) Medium temperature range –20 to +150 °C (–4 to +302 °F) Max. process pressure PN 40, Class 150, 20K Wetted materials Liner: PFA
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone)
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum

Application

Promag H is the preferred sensor for applications with highest requirements in the chemical and life sciences industries. With its genuine loop-powered technology, Promag H 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas thanks to its intrinsically safe design (Ex ia). Heartbeat Technology enables process safety at all times.

* The measuring principle is virtually independent of pressure, density, temperature and viscosity
* Dedicated to the measurement of the smallest flow quantities


Device properties
* Liner made of PFA
* Sensor housing made of stainless steel
* Various electrode materials available
* Loop-powered technology
* High ingress protection: IP69
* Plant safety: worldwide approvals (SIL, Haz. area) 
 

Benefits

* Flexible installation concept – numerous hygienic process connections
* Energy-saving flow measurement – no pressure loss due to cross-section constriction
* Maintenance-free – no moving parts
* Convenient device wiring – separate connection compartment
* Safe operation – no need to open the device due to display with touch control, background lighting
* Integrated verification – Heartbeat Technology

Specification

Model Number Proline Promag H 200
Measuring principle Electromagnetic 
 
Product headline Flowmeter for smallest flow rates with genuine loop-powered technology. 
Dedicated to the measurement of the smallest flow quantities.
Sensor features Flexible installation concept – numerous process connections. Energy‐saving flow measurement – no pressure loss due to cross 
section constriction. Maintenance‐free – no moving parts. 
Liner made of PFA. Sensor housing made of stainless steel. Various electrode materials available.
Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch 
control, background lighting. Integrated verification – Heartbeat Technology. 
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range DN 2 to 25 (¹⁄₁₂ to 1")
Wetted materials Liner: PFA 
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum; Platinum 
Process Connections: stainless steel, 1.4404 (F316L); PVDF; PVC adhesive sleeve 
Seals: O-ring seal (EPDM, FKM, Kalrez), aseptic molded seal (EPDM, FKM, silicone) 
Grounding Rings: stainless steel, 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); tantalum
Measured variables Volume flow, mass flow
Max. measurement error Volume flow: ±0.5 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range 0.06 dm³/min to 300 m³/h (0.015 to 80 gal/min)
Max. process pressure PN 40, Class 150, 20K
Medium temperature range –20 to +150 °C (–4 to +302 °F)
Ambient temperature range –40 to +60 °C (–40 to +140 °F)
Sensor housing material 1.4301 (304), corrosion resistant
Transmitter housing material AlSi10Mg, coated
Degree of protection IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside) 
Configuration via local display and operating tools possible 
Remote display available
Outputs 4‐20 mA HART (passive) 
Pulse/frequency/switch output (passive)
Inputs None
Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply DC 18 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
Hazardous area approvals ATEX, IECEx, cCSAus, INMETRO, NEPSI, EAC, JPN, UK Ex
Product safety CE, C-Tick
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a 
(TÜV SÜD attestation)
Pressure approvals and certificates CRN
Material certificates 3.1 material

 

please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.