Specs at a glance

Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec Measuring range 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d) Medium temperature range Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F) Max. process pressure PN 40, Class 300, 20K Wetted materials Liner material hard rubber: 0 to +80 °C (+32 to +176 °F)
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum

Field of application

With its international approvals for custody transfer as well as drinking water, Promag W serves the broadest variety of applications. It is available as both compact or remote version. Promag W 400 saves time and costs thanks to the broad functionality of its transmitter optimized for Water & Wastewater. In addition, Heartbeat Technology enables measurement reliability and compliant verification.

* The bidirectional measuring principle is virtually independent of pressure, density, temperature and viscosity
* Ideal for water measurement , e.g. drinking water, utility water and industrial/municipal wastewater


Device properties
* International drinking water approvals
* Degree of protection IP68 (Type 6P enclosure)
* Approved for custody transfer to MI-001/OIML R49
* Transmitter housing made of durable polycarbonate or aluminium
* WLAN access
* Integrated data logger: measured values monitoring 
 

Benefits

 * Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss
* Flexible engineering – sensor with fixed or lap-joint process connections
* Application fitness – EN ISO 12944 corrosion protection for underground or underwater installation
* Improved plant availability – sensor compliant with industry-specific requirements
* Safe operation – no need to open the device
* Time-saving local operation without additional software and hardware – integrated web server
* Integrated verification and build-up detection – Heartbeat Technology

Specification

Model Number Proline Promag W 300
Measuring principle Electromagnetic 
 
Product headline Versatile standard flowmeter for the water and wastewater industry. 
Reliable measurement at constant accuracy with 0 x DN inlet run and no pressure loss. 
Ideal for water measurement, e.g. drinking water, utility water and industrial/municipal wastewater.
Sensor features Flexible engineering – sensor with fixed or lap-joint process connections. Application fitness – EN ISO 12944 corrosion protection 
for underground or underwater installation. Improved plant availability – sensor compliant with industry-specific requirements. 
International drinking water approvals. Degree of protection IP68 (Type 6P enclosure). Approved for custody transfer to 
MI-001/OIML R49.
Transmitter features Safe operation – no need to open the device due to display with touch control, background lighting. Time‐saving local operation 
without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. 
Transmitter housing made of durable polycarbonate or aluminium. WLAN access. Integrated data logger: measured values monitoring.
Nominal diameter range DN 25 to 3000(1 to 120")
Wetted materials Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) 
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) 
Liner material PTFE: –20 to +90 °C (–4 to +194 °F) 
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022); Tantalum
Measured variables Volume flow, conductivity, mass flow
Max. measurement error Volume flow (standard): ±0.5 % o.r. ± 1 mm/s (0.04 in/s) 
Volume flow (option): ±0.2 % o.r. ± 2 mm/s (0.08 in/s), Flat Spec
Measuring range 0.5 m3/h to 263000 m3/h (2.5gal/min to 1665 Mgal/d)
Max. process pressure PN 40, Class 300, 20K
Medium temperature range Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) 
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F) 
Liner material PTFE: –20 to +90 °C (–4 to +194 °F)
Ambient temperature range Liner material hard rubber: 0 to +80 °C (+32 to +176 °F) 
Liner material polyurethane: –20 to +50 °C (–4 to +122 °F)
Sensor housing material DN 25 to 300 (1 to 12"): AlSi10Mg, coated 
DN 25 to 3000 (1 to 78"): Carbon steel with protective varnish 
Sensor connection housing (standard): AlSi10Mg, coated 
Sensor connection housing (option): Polycarbonate
Transmitter housing material Polycarbonat; AlSi10Mg, coated
Degree of protection Compact version: IP66/67, type 4X enclosure 
Sensor remote version (standard): IP66/67, type 4X enclosure 
Sensor remote version (option): IP68, type 6P enclosure, with protective varnish 
according to EN ISO 12944 C5‐M/Im1/Im2/Im3 
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside) 
Configuration via local display, web browser and operating tools possible
Outputs 3 ouputs: 
0‐20 mA/4‐20 mA HART (active) 
Pulse/frequency/switch output (passive) 
Pulse/frequency output (passive) 
Switch output (passive)
Inputs Status input
Digital communication HART, PROFIBUS DP, EtherNet/IP, Modbus RS485
Power supply AC 100…240 V / AC/DC 24 V
Hazardous area approvals cCSAus
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR 
Custody transfer according to MI‐001 or OIML R49 (optional class I in combination with 0DN inlet run)
Pressure approvals and certificates CRN
Material certificates 3.1 material
Hygienic approvals and certificates Drinking water approval: ACS, KTW/W270, NSF 61, WRAS BS 6920

 