Endress+Hauser 7D2C Proline Prowirl D200 Vortex Flowmeter

: In stock

: Flow Measurement

: Endress+Hauser

Regular price Sale

OverviewEndress+Hauser 7D2C Proline Prowirl D200 Vortex Flowmeter is a cost-effective wafer flowmeter, available as compact or remote version.Specs at a glance* Max. measurement errorVolume flow (liquid): ±0.75 %Volume...

Overview

Endress+Hauser 7D2C Proline Prowirl D200 Vortex Flowmeter is a cost-effective wafer flowmeter, available as compact or remote version.

Specs at a glance

* Max. measurement error
Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (liquid): ±0.85%
Mass flow (steam, gas): ±1.7 %
* Measuring range
Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
* Medium temperature range
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
* Max. process pressure
PN 40, Class 300, 20K
* Wetted materials
Measuring tube: 1.4408 (CF3M)
DSC sensor: 1.4435 (316/316L)

Field of application

The Prowirl D sensor can be installed directly between flanges and thus serves as the functional device for applications in ancillary processes at little installation cost. With genuine loop-powered technology, Prowirl D 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.
* Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
* For all basic applications and for 1-to-1 replacement of orifice plates.
Device properties
* Face-to-face length of 65 mm (2.56 in)
* No flanges
* Low weight
* Display module with data transfer function
* Robust dual-compartment housing
* Plant safety: worldwide approvals (SIL, Haz. area)

Benefits

 * Integrated temperature measurement for mass/energy flow of saturated steam
* Easy alignment of the sensor – included centering rings
* High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer
* Long-term stability – robust drift-free capacitive sensor
* Convenient device wiring – separate connection compartment
* Safe operation – no need to open the device due to display with touch control, background lighting
* Integrated verification – Heartbeat Technology

Specification

item value
Warranty 1 Year
Customized support OEM
Place of Origin Germany
Brand Name Endress+Hauser
Model Number Prowirl D200
Type Vortex Flowmeter
Product Headline Cost-effective wafer flowmeter, available as compact or remote version. 
Integrated temperature measurement for mass/energy flow of saturated steam. 
For all basic applications and for 1-to-1 replacement of orifice plates.
Sensor Features Easy alignment of the sensor – included centering rings. High availability – proven robustness, resistance to vibrations, 
temperature shocks & water hammer. Long-term stability – robust drift-free capacitive sensor. 
Face-to-face length of 65 mm (2.56 in). No flanges. Low weight.
Transmitter Features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch 
control, background lighting. Integrated verification – Heartbeat Technology. 
Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal Diameter Range DN 15 to 150 (½ to 6")
Wetted Materials Measuring tube: 1.4408 (CF3M) 
DSC sensor: 1.4435 (316/316L)
Measured Variables Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. Measurement Error Volume flow (liquid): ±0.75 % 
Volume flow (steam, gas): ±1.00 % 
Mass flow (liquid): ±0.85% 
Mass flow (steam, gas): ±1.7 %
Measuring Range Liquid: 0.16 to 625 m³/h (0.09 to 368 ft³/min) 
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) 
Steam, gas: 2 to 8342 m³/h (1.18 to 4910 ft³/min) 
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. Process Ppressure PN 40, Class 300, 20K
Medium Temperature Range Standard: –40 to +260 °C (–40 to +500 °F) 
High/low temperature (option): –200 to +400 °C (–328 to +752 °F) 
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
Ambient Temperature Range Compact version (standard): –40 to +80 °C (–40 to +176 °F) 
Compact version (option): –50 to +80 °C (–58 to +176 °F) 
Remote version (standard): –40 to +85 °C (–40 to +185 °F) 
Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor Housing Material Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter Housing Material AlSi10Mg, coated; 1.4404 (316L)
Degree Of Protection Compact version: IP66/67, type 4X enclosure 
Sensor remote version: IP66/67, type 4X enclosure 
Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside) 
Configuration via local display and operating tools possible 
Remote display available
Outputs 4‐20 mA HART (passive) 
4‐20 mA (passive) 
Pulse/frequency/switch output (passive)
Inputs Current input 4‐20 mA (passive)
Digital Communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power Supply DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) 
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) 
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) 
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous Area Approvals ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
Product Safety CE, C-TICK, EAC
Functional Safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals And Certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a 
(TÜV SÜD attestation)
Marine aApprovals And Certificates ABS, LR, BV, DNV
Pressure Approvals And Certificates PED, CRN
Material Certificates 3.1 material 
NACE MR0175/MR0103, PMI (on request)

 