Overview
Endress+Hauser Proline P500 Ultrasonic Clamp-on Flowmeter is a Reliable, flexible, zero maintenance – noninvasive flow measurement, consistently accurate, even under challenging conditions.
Specs at a glance
* Max. measurement error
Volume flow:
±3% o.r. for DN 15
±2% o.r. for DN 25 to DN 200
±2% o.r. above DN 200
* Measuring range
0 to 15 m/s (0 to 50 ft/s)
* Medium temperature range
DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F)
DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F)
DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F)
* Max. process pressure
N/A
Field of application
Prosonic Flow P 500 is the ultrasonic clamp-on flowmeter of choice for safe and maintenance-free measurement of conductive and non-conductive liquids, even in challenging applications. It measures flow noninvasively and idirectionally, independent of pressure, density and conductivity, and without process interruption.
FlowDC makes mounting as flexible as never before. The specified accuracy is maintained at an inlet run of only 2 x DN, even in the case of disturbed flow profiles.
Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.
In addition, Prosonic Flow P 500 is available with:
* high-temperature sensors for measurement up to 550 °C (1022 °F)
* a Petroleum Application Package (PAP), calculating the standard volume for liquid hydrocarbons
* Heartbeat Technology, providing continuous process transparency. This way, build-up can be detected before it affects operation
Benefits
* Flexible mounting – FlowDC reduces inlet runs to a minimum
* High safety standards – Prosonic Flow P 500 is developed according to IEC 61508 functional safety requirements and holds international approvals for hazardous area, Zone 1 and Class I, Division 1
* Reliable measurement performance – proven sensors in combination with maintenance-free mounting system deliver long-term stable signals, also in high-temperature applications (≤550 °C/1022 °F)
* User-friendly operation – the web server offers full remote access, while the device’s touch display offers convenient on-site interaction
* Transparent process insights – Heartbeat Technology with its integrated diagnostics, verification and monitoring functions enable compliance and process safety at all times
* Low capital investment – cost-effectiveness increases with the pipe diameter (up to DN 4000/160")
Specification
item | value |
Warranty | 1 Year |
Customized support | OEM |
Place of Origin | Germany |
Brand Name | Endress+Hauser |
Model Number | Prosonic Flow P500 |
Type | Ultrasonic flow meters |
Product Headline | Clamp-on flowmeter for limited spaces in process industries with up to 3 I/Os. Constant accuracy even when mounted with short inlet run thanks to FlowDC. Bidirectional measurement of various fluids, e.g. liquid hydrocarbons and chemicals. |
Sensor Features | High safety standards – SIL by design, international hazardous area approvals. Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available. Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature: –40 to +550 °C (–40 to +1022 °F). |
Transmitter Features | Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 3 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal Diameter Range | Dual channel, 1 or 2 paths : DN 15 to 4000 (1/2 to 160") |
Sensor Materials | Clamp on system: Sensor holder 1.4301/304, 1.4404/316L Sensor housing 1.4301/304, 1.4404/316L Strapping bands 1.4301/304, 1.4404/316L |
Measured Variables | Volume flow, sound velocity, flow velocity, totalizer |
Max. Measurement Error | Volume flow: ±3% o.r. for DN 15 ±2% o.r. for DN 25 to DN 200 ±2% o.r. above DN 200 |
Measuring Range | 0 to 15 m/s (0 to 50 ft/s) |
Max. Process Pressure | N/A |
Medium Temperature Range | DN 15 to 65 (½to 2½"): –40 to +150°C (–40 +302 °F) DN 50 to 4000 (2 to 160"): –40 to +170°C (–40 to +338 °F) DN 50 to 600 (2" to 24"): 150°C to 550°C (+302 to +1022 °F) |
Ambient Temperature Range | –40 to +60 °C (–40 to +140 °F) –50 to +60 °C (–58 to +140 °F) optional |
Sensor Housing Material | N/A |
Transmitter Housing Material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L |
Degree Of Protection | Sensor remote version: IP68 type 6P Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control(operation from outside) Optional: WLAN Configuration via local display and operating tools possible |
Outputs | 3 outputs: 4-20 mA HART (active/passive) 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital Communication | HART, Modbus RS485 |
Power Supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous Area Approvals | ATEX, FM/CSA, EAC, UK Ex, KC |
Product Safety | CE, C-tick, EAC-marking |
Functional Safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological Approvals And Certificates | Flowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100 Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a |
We normally ship by DHL, UPS, FEDEX or TNT,