Overview Highly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs. Specs at a glance * Max. measurement error Volume flow (standard): - ±0.5 %...

Overview

Highly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs.
Specs at a glance
* Max. measurement error
Volume flow (standard):
- ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
- ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
* Measuring range
0.5 to 10 m/s (1.6 to 33 ft/s)
* Medium temperature range
-40 to +150 °C (-40 to +302 °F)
-40 to +200 °C (-40 to +392 °F) optional
* Max. process pressure
PN 40 / ASME Cl. 300 / JIS 20K
* Wetted materials
Sensor:
A351-CF3M (DN25 to 100)
1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
Transducer: 1.4404/316/316L
Flanges : 1.4404/316/316L or A105/1.0432

Field of application

Prosonic Flow F is the inline sensor with rugged industrial design for Ultrasonic fluid measurement. Combined with the
loop-powered Prosonic Flow 92 transmitter, the device offers easy system integration and accuracy at an attractive price. Prosonic Flow 92F is ideally suited for the chemical and petrochemical industries.
* The measuring principle is independent of pressure, density, temperature, conductivity and viscosity
* Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry

Device properties:
* Full compliance according to NACE MR0175 and MR0103
* Nominal diameter: DN 25 to 300 (1 to 12")
* Medium temperature: –40 to 200 °C (–40 to 392 °F)
* Device as compact or remote version
* 2-line backlit display with push buttons
* HART, PROFIBUS PA, FOUNDATION Fieldbus

Benefits

  * Safe design for process industries – international hazardous area approvals
* No additional pressure loss – full-bore design
* Process transparency – diagnostic capability
* Easy installation and reduced installation costs – loop-powered transmitter
* Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI
* Automatic recovery of data for servicing

Specification

item
value
Warranty
1 Year
Customized support
OEM
Place of Origin
Germany
Brand Name
Endress+Hauser
Model Number
Prosonic Flow 92F
Type
Ultrasonic flow meters
Product Headline
Higly accurate, loop-powered flowmeter with innovative parallel path design for minimum inlet runs.
Inline device for homogeneous conductive and non-conductive liquids in the chemical and petrochemical industry.
Sensor Features
Safe design for process industries – international hazardous area approvals. No additional pressure loss – full-bore design.
Process transparency – diagnostic capability.
Full compliance according to NACE MR0175 and MR010. Nominal diameter: DN 25 to 300 (1 to 12"). Medium temperature: –40 to 200 °C
(–40 to 392 °F).
Transmitter Features
Easy installation and reduced installation costs – loop-powered transmitter. Fully industry compliant – IEC/ATEX/FM/CSA/JPN/NEPSI.
Automatic recovery of data for servicing.
Device as compact or remote version. 2-line backlit display with push buttons. HART, PROFIBUS PA, FOUNDATION Fieldbus.
Nominal Diameter Range
2 path version: DN80 to 300 (3 to12")
3 path version: DN25 to 50 (1 to 2")
4 path version: DN 80 to 300 (3 to 12")
Wetted Materials
Sensor:
A351-CF3M (DN25 to 100)
1.4404/TP316/TP316L or A106 GrB (DN150 to 300)
Transducer: 1.4404/316/316L
Flanges : 1.4404/316/316L or A105/1.0432
Measured Variables
Volume flow, calculated mass flow, sound velocity, flow velocity, signal strength
Max. Measurement Error
Volume flow (standard):
- ±0.5 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Volume flow (option):
- ±0.3 % o.r. for 0.5 to 10 m/s (1.6 to 33 ft/s)
Measuring Range
0.5 to 10 m/s (1.6 to 33 ft/s)
Max. Process Pressure
PN 40 / ASME Cl. 300 / JIS 20K
Medium Temperature Range
-40 to +150 °C (-40 to +302 °F)
-40 to +200 °C (-40 to +392 °F) optional
Ambient Temperature Range
-40 to +60 °C (-40 to +140 °F) compact
-40 to +80 °C (-40 to +176 °F) remote sensor
-40 to +60 °C (-40 to +140 °F) remote transmitter
Transmitter Housing Material
AlSi10Mg, coated
Degree Of Protection
IP67, type 4X enclosure
IP68 type 6P enclosure (option for remote)
Display/Operation
2 lines backlit display with 3 push button
Outputs
1x 4-20 mA HART
1x Pulse/frequency/switch output (passive)
Inputs
N/A
Digital Communication
HART, Profibus PA, FOUNDATION Fieldbus
Power Supply
2 wire loop powered
Hazardous Area Approvals
ATEX,FM, CSA, JPNm UK Ex
Product Safety
EAC marking
Metrological Approvals And Certificates
calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure Approvals And Certificates
CRN, PED, AD2000
Material Certificates
3.1 material (wetted parts)
please contact email for more about the shipping cost