Overview
Compact, accurate and fast RTD sensor with IO-Link for sterile applications.
Accuracy
class A acc. to IEC 60751
Response time
t50 = 1 s
t90 = 1.5 s
Max. process pressure (static)
at 20 °C: 50 bar (725 psi)
Operating temperature range
PT 100:
-50 °C ...200 °C
(-58 °F ...392 °F)
Max. immersion length on request
up to 600,00 mm (23,62'')
Field of application
iTHERM CompactLine TM311 sanitary thermometer provides accurate and fast process temperature measurements in hygienic and aseptic applications. Its temperature sensor offers a 4-wire connection or feeds into a smart temperature transmitter with 4 to 20 mA, IO-Link (auto-detect) or switch output. Featuring TipSens technology, the RTD (Pt100; Class A) delivers response times as low as 1.5 s (t90) for optimum process control. This versatile device is a great choice to drive plant standardization.
- Developed for universal use in sterile applications
- High standardization potential for skid builders, machine and plant manufacturers
- Measuring range: -50 to 200 °C (-58 to 392 °F)
- Pressure range: Up to 50 bar (725 psi)
- Protection class: IP69
- Output: Pt100 (4-wire connection); IO-Link, 4 to 20 mA, 1x PNP switch
- International approvals: 3-A, EHEDG, ASME BPE, FDA, EC 1935/2004, EN 2023/2006, TSE/ADI, GB4806-2016, GB9685-2016; Marine approval acc. to DNV GL
Benefits
* Fast installation and easy commissioning:
- Compact dimensions for installation in tight spaces
- Standard M12 connector with IP69 for easy electrical connection
- Recommended process immersion lengths for optimum measurement
- Preset temperature range
* Excellent temperature measurement performance:
- Short response times as low as 1.5 s (t90)
- High sensor accuracy even with short immersion lengths
- Improved measuring accuracy with transmitter-sensor matching
* Safe and reliable operation:
- Device safety to EN 610101-1 and CSA C/US
- Electromagnetic compatibility (NAMUR NE 21)
- Device diagnostic information (NAMUR NE 43)
- Hygienic design manufactured from high-grade stainless steel
- Marine approval
Specification
Brand Name
|
ENDRESS+HAUSER
|
Model Number
|
TM311 - Pt100
|
Theory
|
Temperature Transmitter
|
Measuring principle
|
Resistance Temperature Detector
|
Measuring range
|
-50 to 200 °C (-58 to 392 °F)
|
Pressure range
|
Up to 50 bar (725 psi)
|
Protection class
|
IP69
|
Output
|
Pt100 (4-wire connection); IO-Link, 4 to 20 mA, 1x PNP switch
|
Characteristic Application
|
metric and imperial style compact temperature probe
fast response time high accuracy standard and hygienic design hygienic process connection threaded process connection |
Thermowell protection tube
|
without incl. thermowell incl. Tee-/elbow thermowell
|
Insert probe
|
pipe version, isolated wires, not flexible
|
Outer diameter protection tube Insert
|
3,0 mm (0,12'') 6,0 mm (0,24'')
|
Max. immersion length on request
|
up to 600,00 mm (23,62'')
|
Material protection tube/ thermowell
|
1.4435 Delta-Ferrit < 1% 316L
|
Process connection
|
compression fitting
Thread weld in adapter clamp connections acc. to ISO2852 screwed pipe joint acc. to DIN 11851 aseptic screwed pipe joint acc. to DIN 11864-1 metallic sealing system thread acc. to ISO 228 for liquiphant adaptor Varivent SMS 1147 Tee-/elbow thermowell |
Tip shape
|
straight reduced
|
International approvals
|
3-A, EHEDG, ASME BPE, FDA, EC 1935/2004, EN 2023/2006, TSE/ADI, GB4806-2016, GB9685-2016; Marine approval acc. to DNV GL
|
Surface roughness Ra
|
0,76 μm (29,92 μin)
0,38 μm (14,96 μin) 0,38 μm (14,96 μin) electropolished |
Max. process pressure (static)
|
at 20 °C: 50 bar (725 psi)
|
Accuracy
|
class A acc. to IEC 60751
|
Response time
|
t50 = 1 s
t90 = 1.5 s |
Integration head transmitter
|
no (4…20mA Signal, IO-Link)
|
Certification
|
3A, EHEDG, ASME BPE, FDA, TSE
1935/2004, 2023/2006, 10/2011 DNVGL, BV CSA C/US General Purpose RCM |
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.