Overview
Memosens 2.0 glass electrode for standard applications in process and water & wastewater industries.
Specs at a glance
* Measurement range ORP: –1 500 … 1 500 mV
Application: A • pH: 1 to 12 Application B • pH: 0 to 14
* Process temperature
Application A: –15 to 80 °C (5 to 176 °F)
Application B: 0 to 135 °C (32 to 275 °F)
* Process pressure
0.8 to 17 bar (11.6 to 246,5 psi) absolute
Application: A • pH: 1 to 12 Application B • pH: 0 to 14
* Process temperature
Application A: –15 to 80 °C (5 to 176 °F)
Application B: 0 to 135 °C (32 to 275 °F)
* Process pressure
0.8 to 17 bar (11.6 to 246,5 psi) absolute
Benefits
* Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
* The additional platinum electrode enables constant monitoring of reference impedance and is a reliable indicator of the sensor quality.
* Simultaneous measurement of pH, ORP and rH values (in rH mode) offers a better process overview and allows for a tighter process control.
* Robust: Large PTFE ring junction and reference with ion trap prevent poisoning of the sensor.
* Suitable for harsh applications: Process glass for highly alkaline media and pressure-stable up to 17 bar (246 psi).
* Reduced operating costs: Lab calibration and fast sensor exchange on site minimize process downtime. Sensor regeneration in the laboratory extends the sensor lifetime.
* Non-contact, digital signal transmission ensures reliable measurements resulting in maximum process safety.
* The additional platinum electrode enables constant monitoring of reference impedance and is a reliable indicator of the sensor quality.
* Simultaneous measurement of pH, ORP and rH values (in rH mode) offers a better process overview and allows for a tighter process control.
* Robust: Large PTFE ring junction and reference with ion trap prevent poisoning of the sensor.
* Suitable for harsh applications: Process glass for highly alkaline media and pressure-stable up to 17 bar (246 psi).
* Reduced operating costs: Lab calibration and fast sensor exchange on site minimize process downtime. Sensor regeneration in the laboratory extends the sensor lifetime.
* Non-contact, digital signal transmission ensures reliable measurements resulting in maximum process safety.
Application
Memosens CPS16E is suitable for simultaneous pH and ORP measurement in applications with long-term stable conditions. Thanks to its pH and ORP elements, the sensor offers a better process overview and enables tighter process control. Memosens CPS16E features
Memosens 2.0 digital technology, offering extended data storage for predictive maintenance. The pH/ORP sensor resists moisture and enables lab calibration which makes the operator's daily tasks easier and maximizes process integrity.
* Long-term monitoring or limit control in processes with stable process conditions:
- Chemical processes
- Pulp and paper industry
- Power stations (e.g. flue gas cleaning)
- Incinerator plants
- Mining
- Wastewater
* Water treatment:
- Drinking water
- Cooling water
- Well water
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
Memosens 2.0 digital technology, offering extended data storage for predictive maintenance. The pH/ORP sensor resists moisture and enables lab calibration which makes the operator's daily tasks easier and maximizes process integrity.
* Long-term monitoring or limit control in processes with stable process conditions:
- Chemical processes
- Pulp and paper industry
- Power stations (e.g. flue gas cleaning)
- Incinerator plants
- Mining
- Wastewater
* Water treatment:
- Drinking water
- Cooling water
- Well water
With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
Specification
Measuring / Application task
|
PH
|
Measuring principle
|
Potentiometric
|
Application
|
Long-term monitoring and limit control in processes with stable process conditions
• Chemical processes • Pulp and paper industry • Waste incinerators and gas scrubbers • Mining • Wastewater |
Characteristic
|
Combination of pH and ORP electrode for standard applications in process technology and environmental engineering
Poison-resistant reference with ion trap |
Measurement range
|
ORP: –1 500 to 1 500 mV
Application A • pH: 1 to 12 Application B • pH: 0 to 14 |
Measuring principle
|
Gel compact electrode with PTFE ring-junction and with ion trap
Pt-disc as additional ORP element rH measurement and control of the reference impedance |
Design
|
All shaft lengths with temperature sensor
Advanced gel technology |
Material
|
Sensor shaft: Glass to suit process
pH membrane glass: Type A, B Metal lead: Ag/AgCl Open aperture: PFTE junction, sterilizable ORP measuring element: Platinum O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
Dimension
|
Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225 and 360 mm (4.72, 8.86, 14.17 and 16.73 inch) |
Process temperature
|
Application A: –15 to 80 °C (5 to 176 °F)
Application B: 0 to 135 °C (32 to 275 °F) |
Process pressure
|
0.8 to 17 bar (11.6 to 246,5 psi) absolute
|
Temperature sensor
|
NTC 30k
|
Ex certification
|
With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2 |
Connection
|
Inductive, digital connection head with Memosens 2.0 technology
|
Ingress protection
|
IP68
|
Measuring / Application task
|
ORP/ Redox
|
Potentiometric
|
Sensor ORP / Redox
|
Application
|
* Long-term monitoring and limit control in processes with stable process conditions
Chemical processes • Pulp and paper industry • Waste incinerators and gas scrubbers • Mining • Wastewater |
Characteristic
|
Combination of pH and ORP electrode for standard applications in process technology and environmental engineering
Poison-resistant reference with ion trap |
Measurement range
|
ORP: –1 500 … 1 500 mV
Application: A • pH: 1 to 12 Application B • pH: 0 to 14 |
Measuring principle
|
Gel compact electrode with PTFE ring-junction with ion trap
Pt-disc as additional ORP element rH measurement and control of the reference impedance |
Design
|
All shaft lengths with temperature sensor
Advanced gel technology |
Material
|
Sensor shaft: Glass to suit process
pH membrane glass: Type A, B Metal lead: Ag/AgCl Open aperture: PFTE junction, sterilizable ORP measuring element: Platinum O-ring: FKM Process coupling: PPS fiber-glass reinforced Nameplate: Ceramic metal oxide |
Dimension
|
Diameter: 12 mm (0.47 inch)
Shaft lengths: 120, 225 and 360 mm (4.72, 8.86, 14.17 and 16.73 inch) |
Process temperature
|
Application A: –15 to 80 °C (5 to 176 °F)
Application B: 0 to 135 °C (32 to 275 °F) |
Process pressure
|
0.8 to 17 bar (11.6 to 246,5 psi) absolute
|
Temperature sensor
|
NTK 30k
|
Ex certification
|
With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use in
hazardous areas Zone 0, Zone 1 and Zone 2 |
Connection
|
Inductive, digital connection head with Memosens 2.0 technology
|
Ingress protection
|
IP68
|
please contact email for more about the shipping cost
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.