Endress+Hauser 6TAB Flow measurement Proline t-mass T150 thermal mass flowmeter

: In stock

: Flow Measurement

: Endress+Hauser

Regular price Sale

OverviewEndress+Hauser Proline t-mass T150 thermal mass flowmeter is a flowmeter for reliable and easy monitoring of liquids.Specs at a glance* Max. measurement errorFlow: ±5 % o.f.s.* Measuring range226...

Overview

Endress+Hauser Proline t-mass T150 thermal mass flowmeter is a flowmeter for reliable and easy monitoring of liquids.

Specs at a glance

* Max. measurement error
Flow: ±5 % o.f.s.
* Measuring range
226 to 14 100 000 l/h (60 to 3 730 000 gal/h)
(under reference conditions)
* Medium temperature range
–20 to +100 °C (–4 to +212 °F)
* Max. process pressure
PN 40
* Wetted materials
Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection:
‐ Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Tri‐Clamp; DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864‐1A, DN50 DIN 11864‐1A: 1.4404 (316L) 
 

Application

The t-mass T 150 is the first thermal mass device from Endress+Hauser for measuring liquids. t-mass T 150 is designed chiefly for water applications. As it measures independently of the electrical conductivity of a fluid and can be used in a variety of water-based and non-water-based liquids for the purpose of monitoring and trending. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
* Measuring principle is characterized by a high operable flow range and direct mass flow measurement
* Dedicated to the monitoring of conductive and non-conductive liquids.
Device properties
* Insertion version for nominal diameter DN 40 to 1000 (1 1/2 to 40")
* Sensor in standard or hygienic version
* SIP cleaning possible up to 130 °C (266 °F)
* Device in compact version with DC 24 V power supply
* 4-20 mA HART, pulse/frequency/switch output
* Compact and robust transmitter

Benefits

* Dedicated to the monitoring of conductive and non-conductive liquids
* High process safety – high repeatability and linearity due to integrated temperature compensation
* Cost-effective measurement – easy installation, negligible pressure loss and maintenance-free
* Reliable flow trending – multivariable measurement
* Fast and efficient commissioning – guided operating menus
* High plant availability – self-diagnostics and error monitoring
* Automatic recovery of data for servicing 
 

Specification 

Measuring Principle Thermal
Product Headline The flowmeter for reliable and easy monitoring of liquids. Dedicated to the monitoring of conductive and non‐conductive liquids.
Sensor Features
High process safety – high repeatability and linearity due to integrated temperature compensation. Cost‐effective measurement – 
easy installation, negligible pressure loss and maintenance‐free. Reliable flow trending – multivariable measurement. Insertion 
version for nominal diameter DN 40 to 1000 (1½ to 40"). Sensor in standard or hygienic version.
Transmitter Features Fast and efficient commissioning – guided operating menus. High plant availability – self‐diagnostics and error monitoring. 
Automatic recovery of data for servicing. Device in compact version with DC 24 V power supply. 4‐20 mA HART, 
pulse/frequency/switch output.
Nominal Diameter Range DN 40 to 1000 (1½ to 40")
Wetted Materials Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) 
Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) 
Connection: 
‐ Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022) 
‐ Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022) 
‐ Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022) 
‐ Tri‐Clamp; DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864‐1A, DN50 DIN 11864‐1A: 1.4404 (316L)
Measured Variables Mass flow, temperature, volume flow
Max. Measurement Error Flow: ±5 % o.f.s.
Measuring Range 226 to 14 100 000 l/h (60 to 3 730 000 gal/h) 
(under reference conditions)
Max. Process Pressure PN 40
Medium Temperature Range –20 to +100 °C (–4 to +212 °F)
Ambient Temperature Range –40 to +60 °C (–40 to +140 °F)
Transmitter Housing Material AlSi10Mg, coated
Degree Of Protection IP66/67, type 4X enclosure
Display/Operation 4‐line display with push buttons 
Configuration via local display and operating tools possible
Outputs 4‐20 mA HART (active) 
Pulse/frequency/switch output (passive)
Inputs Status input
Digital Communication HART
Power Supply DC 18 to 30 V
Hazardous Area Approvals ATEX, IECEx, cCSAus
Other Approvals And Certificates 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR 
Hygienic approvals: EHEDG, 3-A
Metrological Approvals And Certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure Approvals And Certificates CRN
Material Certificates 3.1 material 
 
Hygienic Approvals And Certificates Sanitary approval: 3-A, EHEDG

 

 