OverviewEndress+Hauser 8F5B Proline Promass F500 Coriolis Flowmeter is a flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os.Specs at a glance* Max. measurement...

Overview

Endress+Hauser 8F5B Proline Promass F500 Coriolis Flowmeter is a flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os.

Specs at a glance

* Max. measurement error
Mass flow (liquid): ±0.10 % (standard), 0.05 % (option)
Volume flow (liquid): ±0.10 %
Mass flow (gas): ±0.25 %
Density (liquid): ±0.0005 g/cm³
* Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
* Medium temperature range
Standard: –50 to +150 °C (–58…+302 °F)
Option: –50 to +240 °C (–58…+464 °F)
High temperatur option: –50 to +350 °C (–58…+662 °F)
Option: –196 to +150 °C (–320 to +302 °F)
* Max. process pressure
PN 100, Class 600, 63K
* Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)

Field of application

Promass F has a long-standing reputation as a highly accurate sensor. Immune to fluctuating and harsh environments it is suited for the broadest range of applications. With its innovative remote transmitter Promass F 500 maximizes installation flexibility
and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.
* Measuring principle operates independently of physical fluid properties such as viscosity or density
* Highest measurement performance for liquids and gases under varying, demanding process conditions


Device properties
* Mass flow: measurement error ±0.05 % (PremiumCal)
* Medium temperature: -196 to 350 °C (-320 to 662 °F)
* Nominal diameter: DN 8 to 250 (³⁄₈ to 10")
* Remote version with up to 4 I/Os
* Backlit display with touch control and WLAN access
* Standard cable between sensor and transmitter

Benefits

 * Highest process safety – immune to fluctuating and harsh environments
* Fewer process measuring points – multivariable measurement (flow, density, temperature)
* Space-saving installation – no in-/outlet run needs
* Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology 
 

Specification

item value
Warranty 1 Year
Customized support OEM
Place of Origin Switzerland
Brand Name Endress+Hauser
Model Number Promass F500
Type Coriolis meters, Coriolis flowmeter
Measuring Principle 
 
Coriolis
Product Headline Flowmeter with premium accuracy and robustness, as remote version with up to 4 I/Os. 
Highest measurement performance for liquids and gases under varying, demanding process conditions.
Sensor Features Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement 
(flow, density, temperature). Space‐saving installation – no in-/outlet run needs. 
Mass flow: measurement error ±0.05 % (PremiumCal). Medium temperature: –196 to 350 °C (–320 to 662 °F). Nominal diameter: DN 8 to 250 (³⁄₈ to 10").
Transmitter Features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and 
variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. 
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and 
transmitter.
Nominal Diameter Range DN 8 to 250 (⅜ to 10")
Wetted Materials Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) 
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022); 1.4301 (F304)
Measured Variables Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. Measurement Error Mass flow (liquid): ±0.10 % (standard), 0.05 % (option) 
Volume flow (liquid): ±0.10 % 
Mass flow (gas): ±0.25 % 
Density (liquid): ±0.0005 g/cm³
Measuring Range 0 to 2 200 000 kg/h (0 to 80 840 lb/min)
Max. Process Pressure PN 100, Class 600, 63K
Medium Temperature Range Standard: –50 to +150 °C (–58…+302 °F) 
Option: –50 to +240 °C (–58…+464 °F) 
High temperatur option: –50 to +350 °C (–58…+662 °F) 
Option: –196 to +150 °C (–320 to +302 °F)
Ambient Temperature Range Standard: –40 to +60 °C (–40 to +140 °F) 
Option: –60 to +60 °C (–76 to +140 °F)
Sensor Housing Material Standard: 1.4301 (304), corrosion resistant 
Option: 1.4404 (316L) 
Sensor connection housing (standard): AlSi10Mg, coated 
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L); 1.4409 (CF3M) similar to 316L
Transmitter Housing Material AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat
Degree Of Protection Sensor remote version (standard): IP66/67, type 4X enclosure 
Sensor remote version (option): IP69. 
Transmitter remote version: IP66/67, Type 4X enclosure
Display/Operation 4-line backlit display with touch control (operation from outside) 
Configuration via local display and operating tools possible
Outputs 4 outputs: 
4-20 mA HART (active/passive) 
4-20 mA WirelessHART 
4-20 mA (active/passive) 
Pulse/frequency/switch output (active/passive) 
Double pulse output (active/passive) 
Relay output
Inputs Status input 
4-20 mA input
Digital Communication HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
Power Supply DC 24 V 
AC 100 to 230 V 
AC 100 to 230 V / DC 24 V (non-hazardous area)
Hazardous Area Approvals ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
Product Safety CE, C-tick, EAC marking
Functional Safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals And Certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a 
(TÜV SÜD attestation) 
MI-005 (Liquids other than water, Hydrocarbons, LPG, cryogenic liquids) 
NTEP (Liquids other than water, LPG, cryogenic liquids) 
MC (Liquids other than water, gases, cryogenic liquids) 
MI-002, PTB
Marine Approvals And Certificates LR approval, DNV approval, ABS approval, BV approval, CCS approval
Pressure Approvals And Certificates PED, CRN, AD 2000
Material Certificates 3.1 material 
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic Approvals And Certificates 3-A, EHEDG, cGMP

 