Overview
Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os.
Specs at a glance
* Max. measurement error
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
* Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
* Medium temperature range
–50 to +150 °C (–58 to +302 °F)
* Max. process pressure
PN 40, Class 150, 20K
* Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 %
Density (liquid): ±0.0005 g/cm³
* Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
* Medium temperature range
–50 to +150 °C (–58 to +302 °F)
* Max. process pressure
PN 40, Class 150, 20K
* Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Application
Promass S is at the forefront in hygienic design and dedicated to applications in the food and beverage industry requiring optimal cleanability. The self‐drainable single-tube system ensures careful treatment of fluids. With its innovative remote transmitter Promass S 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables process safety at all times.
* Measuring principle operates independently of physical fluid properties such as viscosity or density
* Dedicated to applications requiring optimal cleanability under hygienic conditions
Device properties
* Large range of hygienic process connections
* 3-A and EHEDG conform
* Fast recovery from CIP/SIP
* Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69
* Backlit display with touch control and WLAN access
* Standard cable between sensor and transmitter
* Measuring principle operates independently of physical fluid properties such as viscosity or density
* Dedicated to applications requiring optimal cleanability under hygienic conditions
Device properties
* Large range of hygienic process connections
* 3-A and EHEDG conform
* Fast recovery from CIP/SIP
* Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69
* Backlit display with touch control and WLAN access
* Standard cable between sensor and transmitter
Benefits
* Increased process safety – easily cleanable and fully self-drainable tube design
* Fewer process measuring points – multivariable measurement (flow, density, temperature)
* Space-saving installation – no in-/outlet run needs
* Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology
* Fewer process measuring points – multivariable measurement (flow, density, temperature)
* Space-saving installation – no in-/outlet run needs
* Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology
Specification
item
|
value
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Promass S500
|
Type
|
Coriolis meters, Coriolis flowmeter
|
Material
|
316/316L
|
Product Headline
|
Easy-to-clean device with self-drainable single-tube system, as remote version with up to 4 I/Os.
Dedicated to applications requiring optimal cleanability under hygienic conditions. |
Sensor Features
|
Increased process safety – easily cleanable and fully self-drainable tube design. Fewer process measuring points – multivariable
measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform. Fast recovery from CIP/SIP. |
Transmitter features
|
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and
variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os; hygienic sensor connection housing with IP69. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal diameter range
|
DN 8 to 50 (⅜ to 2")
|
Wetted Materials
|
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L) |
Measured Variables
|
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
|
Max. Measurement Error
|
Mass flow (liquid): ±0.10 %
Volume flow (liquid): ±0.10 % Density (liquid): ±0.0005 g/cm³ |
Measuring Range
|
0 to 70 000 kg/h (0 to 2570 lb/min)
|
Max. Process Pressure
|
PN 40, Class 150, 20K
|
Medium Temperature Range
|
–50 to +150 °C (–58 to +302 °F)
|
Ambient Temperature Range
|
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F) |
Sensor Housing Material
|
1.4301 (304), corrosion resistant
Sensor connection housing (standard): AlSi10Mg, coated Sensor connection housing (option): 1.4301 (304); 1.4404 (316L) |
Transmitter Housing Material
|
AlSi10Mg, coated; Polycarbonat
|
Degree Of Protection
|
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation
|
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible |
Outputs
|
4 outputs:
4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs
|
Status input
4-20 mA input |
Digital Communication
|
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA
|
Power Supply
|
DC 24 V
AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous Area Approvals
|
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC
|
Product Safety
|
CE, C-Tick, EAC marking
|
Functional Safety
|
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
|
Metrological Approvals And Certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Pressure Approvals And Certificates
|
PED, CRN
|
Material Certificates
|
3.1 material
|
Hygienic Approvals And Certificates
|
3‐A, EHEDG, cGMP
|
please contact email for more about the shipping cost
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.