Endress+Hauser Proline Prosonic Flow B 200 9B2B Ultrasonic Flowmeter

: In stock

: Flow Measurement

: Endress+Hauser

Regular price Sale

Overview  The device for accurate, reliable biogas measurement with loop-powered technology. Specs at a glance * Max. measurement errorVolume flow (standard):‐ ±1.5 % o.r. for 3 to 30...


Overview 

The device for accurate, reliable biogas measurement with loop-powered technology.
Specs at a glance
* Max. measurement error
Volume flow (standard):
‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
Volume flow (option):
‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)
* Measuring range
Standard: 1 to 30 m/s (3.28 to 98.4 ft/s)
Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s)
* Medium temperature range
0 to +80 °C (+32 to +176 °F)
* Max. process pressure
11 bar a (159 psi a)
* Wetted materials
Sensor: 1.4404/1.4435 (316L)
Transducer: HNBR
Temperature sensor (option): AFM 34

Application 

Prosonic Flow B 200 is the specialist for accurate and reliable measurement of wet biogas and digester gas,even under fluctuating process conditions. With its unique integrated real-time methane fraction analysis, Prosonic Flow B 200 enables continuous measurement and monitoring of gas flow as well as gas quality. In addition to efficient process control and energy balancing, Heartbeat Technology enables compliance and process safety at all times.
* The measuring principle is unaffected by gas composition
* Inline flowmeter designed for wet biogas and digester gas under fluctuating process conditions. Device properties:
* Multivariable device: flow, temperature and methane
* Medium temperature: 0 to 80 °C (32 to 176 °F)
* Process pressure: 0.7 to 11 bar a (10.2 to 159 psi a)
* Loop-powered technology
* Robust dual-compartment housing
* Plant safety: worldwide approvals

Benefits

* Integrated real-time methane fraction measurement
* Optimized for low pressure gas – specialized sensor design
* No additional pressure loss – full bore design
* Process transparency – diagnostic capability
* Convenient device wiring – separate connection compartment
* Safe operation – no need to open the device due to display with touch control, background lighting
* Integrated verification – Heartbeat Technology

Specification 

item
value
Warranty
1 Year
Customized support
OEM
Place of Origin
Germany
Brand Name
Endress+Hauser
Model Number
Prosonic Flow B200
Type
Ultrasonic flow meters
Product Headline
The device for accurate, reliable biogas measurement with loop-powered technology.
Inline flowmeter designed for measurement of wet biogas and digester gas under fluctuating process conditions.
Sensor Features
Optimized for low pressure gas – specialized sensor design. No additional pressure loss – full-bore design. Process transparency –
diagnostic capability.
Multivariable device: flow, temperature and methane. Medium temperature: 0 to 80 °C (32 to 176 °F). Process pressure: 0.7 to 11
bar a (10.2 to 159 psi a).
Transmitter Features
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch
control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals.
Nominal Diameter Range
Single‐path version: DN 50 (2"), DN 80 (3")
Two‐path version: DN 100 to 200 (4 to 8")
Wetted Materials
Sensor: 1.4404/1.4435 (316L)
Transducer: HNBR
Temperature sensor (option): AFM 34
Measured Variables
Volume flow, corrected volume flow, corrected methane volume flow, energy flow, methane fraction, calorific value, temperature
Max. Measurement Error
Volume flow (standard):
‐ ±1.5 % o.r. for 3 to 30 m/s (9.84 to 98.4 ft/s)
‐ ±3 % o.r. for 1 to 3 m/s (3.28 to 9.84 ft/s)
Volume flow (option):
‐ ±0.1 % o.f.s. for 0.3 to 1 m/s (0.98 to 3.28 ft/s)
‐ ±1.5 % o.r. for 1 to 30 m/s (3.28 to 98.4 ft/s)
Measuring Range
Standard: 1 to 30 m/s (3.28 to 98.4 ft/s)
Option: 0.3 to 30 m/s (0.98 to 98.4 ft/s)
Max. Process Pressure
11 bar a (159 psi a)
Medium Temperature Range
0 to +80 °C (+32 to +176 °F)
Ambient Temperature Range
Flange material carbon steel: –10 to +60 °C (+14 to +140 °F)
Flange material stainless steel: –40 to +60 °C (–40 to +140 °F)
Transmitter Housing Material
AlSi10Mg, coated; 1.4404 (316L)
Degree Of Protection
IP66/67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs
Current input 4‐20 mA (passive)
Digital Communication
HART
Power Supply
DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch Output)
Hazardous Area Approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, JPN
Metrological Approvals And Certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Pressure Approvals And Certificates
PED
Material Certificates
3.1 material (wetted parts)


please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.