Overview Robust flowmeter with genuine loop-powered technology. Specs at a glance * Max. measurement error Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas):...


Overview

Robust flowmeter with genuine loop-powered technology.
Specs at a glance
* Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³
* Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
* Medium temperature range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F)
* Max. process pressure
PN 100, Class 600, 63K
* Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 ; Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)\

Application

Promass F has a long standing reputation as a highly accurate device. It is suited for broadest range of applications. Promass F200 offers in addition genuine, industry-compliant two-wire technology. This enables seamless system integration into existing infrastructures. Additional advantages are high operational safety in hazardous areas thanks to an intrinsically safe design (Exia) and process safety at all times enabled by Heartbeat Technology.
* Measuring principle operates independently of physical fluid properties such as viscosity or density
* Highest measurement performance for liquids and gases in a wide range of applications
Device properties
* Mass flow: measured error ±0.1 %
* Medium temperature up to +205 °C (+401 °F)
* Nominal diameter: DN 8 to 80 (3/8 to 3")
* Loop-powered technology
* Robust dual-compartment housing
* Plant safety: worldwide approvals (SIL, Haz. area)

Benefits

* Highest process safety – immune to fluctuating and harsh environments
* Fewer process measuring points – multivariable measurement (flow, density, temperature)
* Space-saving installation – no in/outlet run needs
* Convenient device wiring – separate connection compartment
* Safe operation – no need to open the device due to display with touch control, background lighting
* Integrated verification – Heartbeat Technology

Specification 

item
value
Warranty
1 Year
Customized support
OEM
Place of Origin
Switzerland
Brand Name
Endress+Hauser
Model Number
Promass F200
Type
Coriolis meters, Coriolis flowmeter
Measuring Principle
Coriolis
Product Headline
Robust flowmeter with genuine loop-powered technology.
Highest measurement performance for liquids and gases in a wide range of applications.
Sensor Features
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement
(flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Mass flow: measured error ±0.1 %. Medium temperature up to +205 °C (+401 °F). Nominal diameter: DN 8 to 80 (³⁄₈ to 3").
Transmitter Features
Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch
control, background lighting. Integrated verification – Heartbeat Technology.
Loop-powered technology. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal Diameter Range
DN 8 to 80 (⅜ to 3")
Wetted Materials
Measuring tube: 1.4539 (904L); 1.4404; Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Measured Variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. Measurement Error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.25 % Density (liquid): ±0.0005 g/cm³
Measuring Range
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. Process Pressure
PN 100, Class 600, 63K
Medium Temperature Range
Standard: –50 to +150 °C (–58 to +302 °F)
Option: –50 to +205 °C (–58 to +401 °F)
Ambient Temperature Range
–40 to +60 °C (–40 to +140 °F)
Sensor Housing Material
1.4301/1.4307 (304L), corrosion resistant
Transmitter Housing Material
AlSi10Mg, coated, 1.4404 (316L)
Degree Of Protection
IP66/67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control
(operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs
4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs
None
Digital Communication
HART, PROFIBUS PA, FOUNDATION Fieldbus
Power Supply
DC 18 to 35 V (4‐20 mA HART with/without
pulse/frequency/switch)
DC 18 to 30 V (20 mA HART, 4‐20 mA)
DC 9 to 32 V (PROFIBUS PA)
Hazardous Area Approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, JPN, UK Ex
Product Safety
CE, C-TICK
Functional Safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals And Certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
(TÜV SÜD attestation)
Marine Approvals And Certificates
ABS (American Bureau of Shipping)
BV (Bureau Veritas)
LR (Lloyds Register)
BV approval
CCS approval
Pressure Approvals And Certificates
PED, CRN, AD 2000
Material Certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN ISO, ASME, NORSOK
Hygienic Approvals And Certificates
3-A, EHEDG, cGMP