Overview
Economically efficient basis model for level measurement in solids.
Specs at a glance
* Accuracy
+/- 3 mm (0.12 in)
* Process temperature
-40 °C...+80 °C
(-40 °F...+176 °F)
* Process pressure / max. overpressure limit
Vacuum...3 bar
(Vacuum...43.5 psi)
* Max. measurement distance
30 m (98 ft)
* Main wetted parts
PP, UP
+/- 3 mm (0.12 in)
* Process temperature
-40 °C...+80 °C
(-40 °F...+176 °F)
* Process pressure / max. overpressure limit
Vacuum...3 bar
(Vacuum...43.5 psi)
* Max. measurement distance
30 m (98 ft)
* Main wetted parts
PP, UP
Application
Micropilot FMR56 is particularly designed for light-duty process conditions as they occur in silos or bins for solids. Micropilot free space radar is used for continuous,
non-contact level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement.
PP-plated horn antenna can be easily aligned to the surface of the solids by the mounting bracket or a turnable seal.
* Process connections: Mounting bracket or slip-on flange
* Temperature: -40 to +80°C (-40 to +176°F)
* Pressure: -1 to +3bar (-14.5 to +43.5psi)
* Maximum measuring range: 30m (98ft)
* K-band: 26GHz
* International explosion protection certificates, SIL, 5-point linearity protocol
non-contact level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement.
PP-plated horn antenna can be easily aligned to the surface of the solids by the mounting bracket or a turnable seal.
* Process connections: Mounting bracket or slip-on flange
* Temperature: -40 to +80°C (-40 to +176°F)
* Pressure: -1 to +3bar (-14.5 to +43.5psi)
* Maximum measuring range: 30m (98ft)
* K-band: 26GHz
* International explosion protection certificates, SIL, 5-point linearity protocol
Benefits
* Reliable measurement even for changing product and process conditions
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation
* Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)
* Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
* Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
* World's easiest proof test concept for SIL and WHG saves time and cost
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation
* Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)
* Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
* Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
* World's easiest proof test concept for SIL and WHG saves time and cost
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Micropilot FMR56
|
Measuring Principle
|
Level radar
|
Characteristic / Application
|
For simple applications:
Reliable non-contact level measurements in silos or storage tanks for bulk solids |
Specialities
|
Heartbeat Technology,
Bluetooth® commissioning, Operation and maintenance SmartBlue App, Safety and reliability with Multi- Echo Tracking, HistoROM, RFID TAG for easy identification, |
Supply / Communication
|
2-wire (HART/ PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART) Bluetooth® wireless technology and App (optional) |
Frequency
|
K-band (~26 GHz)
|
Antenna
|
Horn DN80/3", PP plated
Horn DN100/4", PP plated |
Accuracy
|
+/- 3 mm (0.12 in)
|
Ambient Temperature
|
-40 °C...+80 °C
(-40 °F...+176 °F) |
Process Temperature
|
-40 °C...+80 °C
(-40 °F...+176 °F) |
Process Pressure / max. Overpressure Limit
|
Vacuum...3 bar
(Vacuum...43.5 psi) |
Main Wetted Parts
|
PP, UP
|
Process Connection
|
Flange:
UNI DN80...DN150 (3"...6") Mounting bracket |
Max. Measurement Distance
|
30 m (98 ft)
|
Communication
|
4...20 mA HART
PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology |
Certificates / Approvals
|
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC Ex, KC, UK Ex
|
Safety Approvals
|
SIL
|
Options
|
Display,
Customized parameterization Remote operation via SmartBlue App using Bluetooth® |
Application Limits
|
DK < 1.6
Reduction of the max. possible measuring range through: Media with poor reflection properties Angle of repose Extremely loose surfaces of bulk solids, e.g. bulk solids with low bulk weight for pneumatic filling Build-up, above all of moist products |
please contact email for more about the shipping cost
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.