Endress+Hauser 6F5B Proline T-mass F500 Thermal Mass Flowmeter

: In stock

: Flow Measurement

: Endress+Hauser

Regular price Sale

OverviewEndress+Hauser Proline T-mass F500 Thermal Mass Flowmeter is an inline flowmeter with long-term stability as remote version with up to 4 I/Os.Specs at a glance* Max. measurement errorGas:...

Overview

Endress+Hauser Proline T-mass F500 Thermal Mass Flowmeter is an inline flowmeter with long-term stability as remote version with up to 4 I/Os.

Specs at a glance

* Max. measurement error
Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
* Measuring range
0.5 to 3750 kg/h (1.1 to 8250 lb/h)
* Medium temperature range
-40 °C to +180°C (-40 °F to +356 °F)
* Max. process pressure
PN40 / Cl. 300 / 20K
* Wetted materials
Measuring tubes
• DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408
• DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L)
Process connections
Flange connections
Stainless steel, 1.4404 (F316/F316L)
Threaded connections
Stainless steel, 1.4404 (316/316L)
Sensing element
Unidirectional
• Stainless steel, 1.4404 (316/316L)
• Alloy C22, 2.4602 (UNS N06022);
Bidirectional
Stainless steel, 1.4404 (316/316L)
Reverse flow detection
Stainless steel, 1.4404 (316/316L) 
 

Field of application

The patented sensor design of t-mass F provides unprecedented measurement stability in thermal inline mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. The innovative remote transmitter von t-mass F 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat
Technology enables measurement reliability and compliant verification.
* Measuring principle is characterized by a high operable flow range and direct mass flow measurement
* Measurement of utility and process gases as well as gas mixtures in small line sizes
Device properties
* Inline version with DN 15 to 100 (1/2 to 4")
* Bidirectional measurement; high measuring performance
* Patented drift-free sensor with SIL 2
* Remote version with up to 4 I/Os
* Backlit display with touch control and WLAN access
* Standard cable between sensor and transmitter 
 

Benefits

 * Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
* High level of process control – premium measurement accuracy and repeatability
* Reliable monitoring – detection of process disturbances and reverse flow
* Easy maintenance – removable sensor
* Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology 
 

Specification

Measuring Principle Thermal
Product Headline Inline flowmeter with long-term stability as remote version with up to 4 I/Os. 
Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof. 
Measurement of utility and process gases as well as gas mixtures in small line sizes.
Sensor Features High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process 
disturbances and reverse flow. Easy maintenance – removable sensor. 
Inline version with DN 15 to 100 (½ to 4"). Bidirectional measurement; high measuring performance. Patented drift-free sensor with 
SIL 2.
Transmitter Features Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and 
variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. 
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and 
transmitter.
Nominal Diameter Range DN 15 to DN 100 (1/2" to 4")
Wetted Materials Measuring tubes 
• DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408 
• DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L) 
Process connections 
Flange connections 
Stainless steel, 1.4404 (F316/F316L) 
Threaded connections 
Stainless steel, 1.4404 (316/316L) 
Sensing element 
Unidirectional 
• Stainless steel, 1.4404 (316/316L) 
• Alloy C22, 2.4602 (UNS N06022); 
Bidirectional 
Stainless steel, 1.4404 (316/316L) 
Reverse flow detection 
Stainless steel, 1.4404 (316/316L)
Measured Variables Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density
Max. Measurement Error Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
Measuring Range 0.5 to 3750 kg/h (1.1 to 8250 lb/h)
Max. Process Pressure PN40 / Cl. 300 / 20K
Medium Temperature Range -40 °C to +180°C (-40 °F to +356 °F)
Ambient Temperature Range -40 to 60°C (-40 to 140°F) 
Optional: 
Transmitter: -50 to 60°C (-50 to 140°F), 
Sensor: -60 to 60°C (-60 to 140°F)
Transmitter Housing Material Aluminium, AlSi10Mg, coated 
Polycarbonate
Degree Of Protection IP66/67, Type 4X enclosure Sensor: IP68, Type 6P (optional)
Display/Operation 4-line backlit display with touch control (operation from outside) 
Configuration via local display and operating tools possible
Outputs 4 outputs: 
4-20 mA HART (active/passive) 
4-20 mA (active/passive) 
Pulse/frequency/switch output (active/passive) 
Relay output
Inputs Status input 
4-20 mA input
Digital Communication HART, Modbus RS485
Power Supply DC 24V 
AC 100 to 240V
Hazardous Area Approvals ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC, KC
Product Safety CE, C-tick
Functional Safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals And Certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Pressure Approvals And Certificates PED, CRN
Material Certificates 3.1 material 
NACE MR0175/MR0103

 

please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.