Overview
Endress Hauser Proline Promass F300 Coriolis Flowmeter is an inline flowmeter with long-term stability and a compact, easily accessible transmitter.
Specs at a glance
* Max. measurement error Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
* Measuring range :0.5 to 3750 kg/h (1.1 to 8250 lb/h)
* Medium temperature range :-40 °C to +180°C (-40 °F to +356 °F)
* Max. process pressure : PN40 / Cl. 300 / 20K
* Wetted materials
Measuring tubes
DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408
DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L)
Process connections
Flange connections:Stainless steel, 1.4404 (F316/F316L)
Threaded connections:Stainless steel, 1.4404 (316/316L)
Sensing elementUnidirectional
Stainless steel, 1.4404 (316/316L) Alloy C22, 2.4602 (UNS N06022);
Bidirectional Stainless steel, 1.4404 (316/316L)
Reverse flow detection Stainless steel, 1.4404 (316/316L)
Benefits
* Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
* High level of process control – premium measurement accuracy and repeatability
* Reliable monitoring – detection of process disturbances and reverse flow
* Easy maintenance – removable sensor
* Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology
Application
The patented sensor design of t-mass F provides unprecedented measurement stability in thermal inline mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. Its compact
transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and compliant verification.
* Measuring principle is characterized by a high operable flow range and direct mass flow measurement
* Measurement of utility and process gases as well as gas mixtures in small line sizes Device properties
* Inline version with DN 15 to 100 (1/2 to 4")
* Bidirectional measurement; high measuring performance
* Patented drift-free sensor with SIL 2
* Compact dual-compartment housing with up to 3 I/Os
* Backlit display with touch control and WLAN access
* Remote display available
Specification
Measuring principle | Vortex |
Product headline | Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy. Easy energy management – integrated temperature and pressure measurement for steam and gases. Suitable for a wide range of applications; optimized for steam applications. |
Sensor features | Space-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term stability – robust drift-free capacitive sensor. Wet steam capabilities for DN 25 to 300 (1 to 12"). Flexible positioning of pressure cell. Industrial siphon design for pressure measurement. |
Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology. Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area). |
Nominal diameter range | DN 15 to 300 (½ to 12") |
Wetted materials | Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602 DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602 Process connection: 1.4404/F316/F316L); 2.4602 |
Measured variables | Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperatur |
Max. measurement error | Volume flow (liquid): ±0.75 % Volume flow (optional): ±0.65 % Volume flow (steam, gas): ±1.00 % Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated) Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation) Mass flow (liquid): ±0.85% |
Measuring range | Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min) depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) |
Max. process pressure | PN 100, Class 600, 20K |
Medium temperature range | Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F) |
Ambient temperature range | Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F) Remote version (standard): –40 to +85 °C (–40 to +185 °F) Remote version (option): –50 to +85 °C (–58 to +185 °F) |
Sensor housing material | Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M) |
Transmitter housing material | AlSi10Mg, coated; 1.4404 (316L) |
Degree of protection | Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure Transmitter remote version: IP66/67, type 4X enclosure |
Display/Operation | 4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available |
Outputs | 4‐20 mA HART (passive) 4‐20 mA (passive) Pulse/frequency/switch output (passive) |
Inputs | Current Input 4‐20 mA (passive) |
Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus |
Power supply | DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output) |
Hazardous area approvals | ATEX, IECEx, cCSAus, JPN, EAC |
Product safety | CE, C-TICK, EAC, UK Ex |
Functional safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological approvals and certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Marine approvals and certificates | ABS, LR, BV, DNV |
Pressure approvals and certificates | PED, CRN, AD 2000 |
Material certificates | 3.1 material NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request) |
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.