overviewEndress+Hauser 7R2C Proline Prowirl R200 Vortex Flowmeter with best-in-class accuracy despite pipe reduction.Specs at a glance* Max. measurement error Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 % Mass...

overview

Endress+Hauser 7R2C Proline Prowirl R200 Vortex Flowmeter with best-in-class accuracy despite pipe reduction.

Specs at a glance

* Max. measurement error 
Volume flow (liquid): ±0.75 % 
Volume flow (steam, gas): ±1.00 % 
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated) 
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure 
compensation) 
Mass flow (liquid): ±0.85% 
* Measuring range 
Liquid: 0.1 to 540 m³/h (0.061 to 320 ft³/min) 
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) 
Steam, gas: 0.52 to 7300 m³/h (0.31 to 4300 ft³/min) 
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) 
* Medium temperature range 
Standard: –40 to +260 °C (–40 to +500 °F) 
High/low temperature (option): –200 to +400 °C (–328 to +752 °F) 
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F) 
* Max. process pressure 
PN 40, Class 300, 20K 
* Wetted materials 
Measuring tube: 1.4408 (CF3M) 
DSC sensor: 1.4404/F316/F316L 
Process connection: 1.4404/F316/F316L

Field of application

Prowirl R was designed for low flows and is thus the particularly dependable solution for energy management. Additionally its calibration option PremiumCal guarantees excellent measuring accuracy for maximum plant availability. With genuine loop-powered technology, Prowirl R 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.
* Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
* Dedicated to applications with very low or reduced flow Device properties
* Integrated diameter reduction by 1 or 2 line sizes
* Nominal diameter (mating pipe) up to DN 250 (10")
* Flexible positioning of pressure cell
* Display module with data transfer function
* Robust dual-compartment housing
* Plant safety: worldwide approvals (SIL, Haz. area)

Benefits

 * Easy energy management – integrated temperature and pressure measurement for steam and gases
* Cost and time savings – no pipework modifications needed for line size reduction
* Same accuracy down to Re 10 000 – most linear Vortex meter body
* Long-term stability – robust drift-free capacitive sensor
* Convenient device wiring – separate connection compartment, various Ethernet options
* Safe operation – no need to open the device
* Integrated verification – Heartbeat Technology

Specification

item value
Warranty 1 Year
Customized support OEM
Place of Origin Germany
Brand Name Endress+Hauser
Model Number Prowirl R200
Type Vortex Flowmeter
Product Headline Flowmeter with best-in-class accuracy despite pipe reduction. 
Easy energy management – integrated temperature and pressure measurement for steam and gases. 
Dedicated to applications with very low flow or reduced flow.
Sensor Features Cost and time savings – no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 – most linear 
Vortex meter body. Long-term stability – robust drift-free capacitive sensor. Integrated diameter reduction by 1 or 2 line sizes. 
Nominal diameter (mating pipe) up to DN 250 (10").
Transmitter Features Cost and time savings – no pipework modifications needed for line size reduction. Same accuracy down to Re 10 000 – most linear 
Vortex meter body. Long-term stability – robust drift-free capacitive sensor. 
Integrated diameter reduction by 1 or 2 line sizes. Nominal diameter (mating pipe) up to DN 250 (10"). Flexible positioning of 
pressure cell.
Nominal Diameter Range DN 25 to 250 (1 to 10")
Wetted Materials Measuring tube: 1.4408 (CF3M) 
DSC sensor: 1.4404/F316/F316L 
Process connection: 1.4404/F316/F316L
Measured Variables Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. Measurement Error Volume flow (liquid): ±0.75 % 
Volume flow (steam, gas): ±1.00 % 
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated) 
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure 
compensation) 
Mass flow (liquid): ±0.85%
Measuring Range Liquid: 0.1 to 540 m³/h (0.061 to 320 ft³/min) 
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) 
Steam, gas: 0.52 to 7300 m³/h (0.31 to 4300 ft³/min) 
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. Process Ppressure PN 40, Class 300, 20K
Medium Temperature Range Standard: –40 to +260 °C (–40 to +500 °F) 
High/low temperature (option): –200 to +400 °C (–328 to +752 °F) 
High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
Ambient Temperature Range Compact version (standard): –40 to +80 °C (–40 to +176 °F) 
Compact version (option): –50 to +80 °C (–58 to +176 °F) 
Remote version (standard): –40 to +85 °C (–40 to +185 °F) 
Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor Housing Material Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter Housing Material AlSi10Mg, coated; 1.4404 (316L)
Degree Of Protection Compact version: IP66/67, type 4X enclosure 
Sensor remote version: IP66/67, type 4X enclosure 
Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside) 
Configuration via local display and operating tools possible 
Remote display available
Outputs 4‐20 mA HART (passive) 
4‐20 mA (passive) 
Pulse/frequency/switch output (passive)
Inputs 4‐20 mA (passive)
Digital Communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power Supply DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) 
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) 
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) 
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous Area Approvals ATEX, IECEx, cCSAus, JPN, EAC, UK Ex
Product Safety CE, C-tick, EAC
Functional Safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals And Certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a 
(TÜV SÜD attestation)
Marine aApprovals And Certificates ABS, LR, BV, DNV
Pressure Approvals And Certificates PED, CRN, AD 2000
Material Certificates 3.1 material 
NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)

 

please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,