Endress+Hauser 7F2C Proline Prowirl F200 Vortex Flowmeter

: In stock

: Flow Measurement

: Endress+Hauser

Regular price Sale

OverviewEndress+Hauser Proline Prowirl F200 Vortex Flowmeter is a versatile flowmeter with detection of wet steam conditions and best-in-class accuracy.Specs at a glance* Max. measurement error Volume flow (liquid): ±0.75...

Overview

Endress+Hauser Proline Prowirl F200 Vortex Flowmeter is a versatile flowmeter with detection of wet steam conditions and best-in-class accuracy.

Specs at a glance

* Max. measurement error 
Volume flow (liquid): ±0.75 % 
Volume flow (optional): ±0.65 % 
Volume flow (steam, gas): ±1.00 % 
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated) 
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure 
compensation) 
Mass flow (liquid): ±0.85% 
* Measuring range 
Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min) 
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) 
Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min) 
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) 
* Medium temperature range 
Standard: –40 to +260 °C (–40 to +500 °F) 
High/low temperature (option): –200 to +400 °C (–328 to +752 °F) 
* Max. process pressure 
PN 100, Class 600, 20K 
* Wetted materials 
Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602 
DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602 
Process connection: 1.4404/F316/F316L); 2.4602

Field of application

Prowirl F is the multivariable flowmeter with inline wet steam measurement. Its calibration option PremiumCal guarantees excellent measuring accuracy and highest plant availability at low flow rates of gas, steam and liquids. With genuine loop-powered technology, Prowirl F 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.
* Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
* Suitable for a wide range of applications; optimized for steam applications
Device properties
* Wet steam capabilities for DN 25 to 300 (1 to 12")
* Flexible positioning of pressure cell
* Industrial siphon design for pressure measurement
* Display module with data transfer function
* Robust dual-compartment housing
* Plant safety: worldwide approvals (SIL, Haz. area)

Benefits

 * Easy energy management – integrated temperature and pressure measurement for steam and gases
* Reliable, secure measurement technology – compliance with international Vortex standard ISO 12764
* Same accuracy down to Re 10 000 – most linear Vortex meter body
* Long-term stability – robust drift-free capacitive sensor
* Convenient device wiring – separate connection compartment, various Ethernet options
* Safe operation – no need to open the device
* Integrated verification – Heartbeat Technology

Specification

item value
Warranty 1 Year
Customized support OEM
Place of Origin Germany
Brand Name Endress+Hauser
Model Number Prowirl F200
Type Vortex Flowmeter
Product Headline Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy. 
Easy energy management – integrated temperature and pressure measurement for steam and gases. 
Suitable for a wide range of applications; optimized for steam applications.
Sensor Features Space-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term 
stability – robust drift-free capacitive sensor. 
Wet steam capabilities for DN 25 to 300 (1 to 12"). Flexible positioning of pressure cell. Industrial siphon design for pressure 
measurement.
Transmitter Features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch 
control, background lighting. Integrated verification – Heartbeat Technology. 
Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal Diameter Range DN 15 to 300 (½ to 12")
Wetted Materials Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602 
DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602 
Process connection: 1.4404/F316/F316L); 2.4602
Measured Variables Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature
Max. Measurement Error Volume flow (liquid): ±0.75 % 
Volume flow (optional): ±0.65 % 
Volume flow (steam, gas): ±1.00 % 
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated) 
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure 
compensation) 
Mass flow (liquid): ±0.85%
Measuring Range Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min) 
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F) 
Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min) 
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. Process Ppressure PN 100, Class 600, 20K
Medium Temperature Range Standard: –40 to +260 °C (–40 to +500 °F) 
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
Ambient Temperature Range Compact version (standard): –40 to +80 °C (–40 to +176 °F) 
Compact version (option): –50 to +80 °C (–58 to +176 °F) 
Remote version (standard): –40 to +85 °C (–40 to +185 °F) 
Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor Housing Material Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter Housing Material AlSi10Mg, coated; 1.4404 (316L)
Degree Of Protection Compact version: IP66/67, type 4X enclosure 
Sensor remote version: IP66/67, type 4X enclosure 
Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside) 
Configuration via local display and operating tools possible 
Remote display available
Outputs 4‐20 mA HART (passive) 
4‐20 mA (passive) 
Pulse/frequency/switch output (passive)
Inputs Current Input 4‐20 mA (passive)
Digital Communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power Supply DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output) 
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA) 
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input) 
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous Area Approvals ATEX, IECEx, cCSAus, JPN, EAC
Product Safety CE, C-TICK, EAC, UK Ex
Functional Safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological Approvals And Certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) 
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a 
(TÜV SÜD attestation)
Marine aApprovals And Certificates ABS, LR, BV, DNV
Pressure Approvals And Certificates PED, CRN, AD 2000
Material Certificates 3.1 material 
NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)

 

please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.