Overview
SITRANS FUS060 is a transit time based transmitter designed for ultrasonic flowmetering with dedicated sensors in the FUS inline
series up to DN 500. SITRANS FUS060 is engineered for high performance and is suitable for 1- and 2-path flowmeters.
series up to DN 500. SITRANS FUS060 is engineered for high performance and is suitable for 1- and 2-path flowmeters.
Benefits
* Superior signal resolution for optimum turn down ratio
* Simple menu-based local operation with two-line display and four optical input elements, for unlimited use in potentially explosive atmospheres
* Self-monitoring and diagnostic
* Operate up to 2 paths
* Remote installation up to 120 m from sensor
* 1 analog output (4 to 20 mA) standard with HART-protocol, 1 digital frequency or pulse output, 1 relay output for limit,alarms, flow direction
* PROFIBUS PA Profile 2, 1 digital frequency or pulse output
* Simple menu-based local operation with two-line display and four optical input elements, for unlimited use in potentially explosive atmospheres
* Self-monitoring and diagnostic
* Operate up to 2 paths
* Remote installation up to 120 m from sensor
* 1 analog output (4 to 20 mA) standard with HART-protocol, 1 digital frequency or pulse output, 1 relay output for limit,alarms, flow direction
* PROFIBUS PA Profile 2, 1 digital frequency or pulse output
Application
The main application for flowmeters with the transmitter SITRANS FUS060 is measurement volume of water and waste water.
Design
The transmitter FUS060 is designed for use in a flowmeter system together with sensors type SONOKIT, SONO 3300 and SONO 3100.The FUS060 is ordered as part of a complete flowmeter system. It can be ordered separately as spare part and manually programmed with the sensor data.
Function
Displays and keypad
Operation of the SITRANS FUS060 transmitter can be carried out using:
* Keypad and display unit
* HART communicator
* PC/laptop and SIMATIC PDM software via HART communication
* PC/laptop and SIMATIC PDM software using PROFIBUS PA communication
Operation of the SITRANS FUS060 transmitter can be carried out using:
* Keypad and display unit
* HART communicator
* PC/laptop and SIMATIC PDM software via HART communication
* PC/laptop and SIMATIC PDM software using PROFIBUS PA communication
HART communication
PROFIBUS PA communication
The operating and display panel permits simple operation without supplementary equipment. It is not necessary to open the housing.All changes to a setting can therefore also be carried out in the potentially explosive atmosphere.
Operating and display panel
The individual functions and parameters are selected using a hierarchical, multi-language input menu and four infrared keys. Theparameters can be specifically selected and modified using codes, e.g.:
* Operating parameters such as measuring range, physical dimensions, device information
* Limits for flow, totalizer, ultrasonic velocity or ultrasonic amplitude
* Noise suppression using damping, error stages and hysteresis
* Display parameters (freely-configurable display)
* Display in volume or mass dimensions
* Density as constant input value for conversion of volume into mass dimensions
* Forward/backward measurement
* Flow direction
* Diagnostics functions and control values
* Functions of the PROFIBUS PA output:
flow, net quantity (volume or mass), ultrasonic velocity, ultrasonic amplitude, forward quantity (volume or mass), backward
quantity (volume or mass)
* Functions of the analog output:flow, ultrasonic velocity or ultrasonic amplitude
* Functions of digital output 1:pulse output, frequency output, limit, flow direction or device status
* Functions of digital output 2:limit, flow direction or device status
* Simulation of output signal via analog output, digital output 1 and digital output 2
The HART protocol is implemented via the analog output (current output). Using this communication facility, the device can be parameterized with a PC/laptop and SIMATIC PDM software in addition to local operation.In the version with PROFIBUS PA, the analog output is replaced by the digital PROFIBUS PA output. The device can then be parameterized via PROFIBUS communication and with SIMATIC PDM in addition to local operation.
* Limits for flow, totalizer, ultrasonic velocity or ultrasonic amplitude
* Noise suppression using damping, error stages and hysteresis
* Display parameters (freely-configurable display)
* Display in volume or mass dimensions
* Density as constant input value for conversion of volume into mass dimensions
* Forward/backward measurement
* Flow direction
* Diagnostics functions and control values
* Functions of the PROFIBUS PA output:
flow, net quantity (volume or mass), ultrasonic velocity, ultrasonic amplitude, forward quantity (volume or mass), backward
quantity (volume or mass)
* Functions of the analog output:flow, ultrasonic velocity or ultrasonic amplitude
* Functions of digital output 1:pulse output, frequency output, limit, flow direction or device status
* Functions of digital output 2:limit, flow direction or device status
* Simulation of output signal via analog output, digital output 1 and digital output 2
The HART protocol is implemented via the analog output (current output). Using this communication facility, the device can be parameterized with a PC/laptop and SIMATIC PDM software in addition to local operation.In the version with PROFIBUS PA, the analog output is replaced by the digital PROFIBUS PA output. The device can then be parameterized via PROFIBUS communication and with SIMATIC PDM in addition to local operation.
Integration
The transmitter output is often used as input for an automation system or as input for systems of remote reading.The SITRANS FUS060 transmitter offers current, pulse and relay outputs as standard output functions and supports HART or Profibus PA communication.The settings of the transmitter output functions are individually programmed via keypad and display menu.
Specification
item
|
value
|
Warranty
|
1 Year
|
Customized support
|
OEM, ODM, OBM
|
Place of Origin
|
Germany
|
Brand Name
|
SIEMENS
|
Model Number
|
SITRANS FUS060 transmitter
|
Type
|
Ultrasonic meters
|
Material
|
|
Nominal sizes and number of paths
|
2-path DN 100~500 (4" ... 20")
|
Signal range
|
4~20 mA
|
Upper limit
|
20~22.5 mA, adjustable
|
Signal on alarm
|
3.6 mA, 22 mA, or 24 mA
|
Repeatability
|
≤ ± 0,25 % of measured value at 0.5 ... 10 m/s
|
Operation Ambient temperature
|
-20 ... +50 °C (-4 ... +122 °F)
|
Enclosure rating
|
IP65 (NEMA 4)
|
Process temperature
|
-200 ... +250 °C (-328 ... +482 °F)
|
Enclosure material
|
Die-cast aluminium, painted
|
Weigth of transmitter
|
4.4 kg (9.7 lb)
|
please contact email for more about the shipping cost
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.