Basic model for level liquid applications.
Specs at a glance
* Accuracy
+/- 2 mm (0.08 in)
* Process temperature
-40...+130 °C
(-40...+266 °F)
* Process pressure / max. overpressure limit
Vacuum...3 bar
(Vacuum...43.5 psi)
* Max. measurement distance
Standard: 30 m (98 ft)
With advanced dynamics: 40 m (131 ft)
* Main wetted parts
PVDF, Viton, PP, PBT
+/- 2 mm (0.08 in)
* Process temperature
-40...+130 °C
(-40...+266 °F)
* Process pressure / max. overpressure limit
Vacuum...3 bar
(Vacuum...43.5 psi)
* Max. measurement distance
Standard: 30 m (98 ft)
With advanced dynamics: 40 m (131 ft)
* Main wetted parts
PVDF, Viton, PP, PBT
Application
Micropilot FMR50 is the best choice in simple reservoir and storage applications as well as in utility processes. The FMR50 free space radar is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors. Remote access with SmartBlue app via Bluetooth module is available.
Encapsulated PVDF or PP-plated horn antenna.
* Process connections: Thread, mounting bracket or slip-on flange
* Temperature: -40 to +130°C (-40 to +266°F)
* Pressure: -1 to +3bar (-14.5 to +43.5psi)
* Maximum measuring range: 30m (98ft), 40m (131ft) for enhanced dynamics
* Accuracy: ±2mm
* K-band: 26GHz
* International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol
Encapsulated PVDF or PP-plated horn antenna.
* Process connections: Thread, mounting bracket or slip-on flange
* Temperature: -40 to +130°C (-40 to +266°F)
* Pressure: -1 to +3bar (-14.5 to +43.5psi)
* Maximum measuring range: 30m (98ft), 40m (131ft) for enhanced dynamics
* Accuracy: ±2mm
* K-band: 26GHz
* International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol
Benefits
* Reliable non-contact measurement even for changing product and process conditions
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation
* Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)
* Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
* Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
* World's easiest proof test concept for SIL and WHG saves time and cost
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation
* Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)
* Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
* Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
* World's easiest proof test concept for SIL and WHG saves time and cost
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Micropilot FMR50
|
Measuring Principle
|
Level radar
|
Characteristic / Application
|
For basic level measurement in liquids, pastes and slurries; non affected by changing media, temperature changes, gas blankets or
vapor; Encapsulated PVDF or PP clad horn antenna |
Specialities
|
Heartbeat Technology,
SIL 2 according to IEC 61508, Bluetooth® commissioning, Operation and maintenance SmartBlue App, Safety and reliability with Multi-Echo Tracking, HistoROM, RFID TAG for easy identification |
Supply / Communication
|
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART) Bluetooth® wireless technology and App (optional) |
Frequency
|
K-band (~26 GHz)
|
Accuracy
|
+/- 2 mm (0.08 in)
|
Ambient Temperature
|
-40...+80 °C
(-40...+176 °F) |
Process Temperature
|
-40...+130 °C
(-40...+266 °F) |
Process Pressure / max. Overpressure Limit
|
Vacuum...3 bar
(Vacuum...43.5 psi) |
Main Wetted Parts
|
PVDF, Viton, PP, PBT
|
Process Connection
|
Thread:
G1 1/2, MNPT1 1/2 Flange: UNI DN80...DN150 (3"...6") |
Process Connection Hygienic
|
|
Max. Measurement Distance
|
Standard: 30 m (98 ft)
With advanced dynamics: 40 m (131 ft) |
Communication
|
4...20 mA HART
PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology |
Certificates / Approvals
|
ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex
|
Safety Approvals
|
Overfill protection WHG
SIL |
Design Approvals
|
EN 10204-3.1
NACE MR0175, MR0103 ASME B31.3 AD2000 |
Options
|
Display,
Customized parameterization, PWIS free, Remote operation via SmartBlue App using Bluetooth® |
Application Limits
|
Ammoniacal gas phase:
FMR54 in stilling well Strong build-up formation: FMR54 with air purge Low DK: FMR51 Only PTFE resistant: FMR52 Custody transfer measurement: FMR5xx |
please contact email for more about the shipping cost
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.