Overview
Highest performance pressure sensor with the Contite cell for hydrostatic level measurement.
Specs at a glance
* Accuracy
Standard 0.1%
Optional 0.075%
* Process temperature
-10°C...+100°C
(+14°F...+212°F)
* Pressure measuring range
100 mbar...10 bar
(1.5 psi...150 psi)
* Process pressure / max. overpressure limit
40 bar (600 psi)
* Main wetted parts
Alloy C
316L
* Max. measurement distance
100 m (328 ft) H2O
* Material process membrane
316L, AlloyC,
Gold-Rhodium
* Measuring cell
100 mbar...10 bar
(1.5 psi...150 psi)
Standard 0.1%
Optional 0.075%
* Process temperature
-10°C...+100°C
(+14°F...+212°F)
* Pressure measuring range
100 mbar...10 bar
(1.5 psi...150 psi)
* Process pressure / max. overpressure limit
40 bar (600 psi)
* Main wetted parts
Alloy C
316L
* Max. measurement distance
100 m (328 ft) H2O
* Material process membrane
316L, AlloyC,
Gold-Rhodium
* Measuring cell
100 mbar...10 bar
(1.5 psi...150 psi)
Field of application
The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters
easy. Designed according to IEC 61508 for use in SIL3 safety systems.
For level and/or pressure measurement.
* Process connections: Threads, flanges and hygienic connections
* Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
* Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)
* Accuracy: ±0.075%
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
easy. Designed according to IEC 61508 for use in SIL3 safety systems.
For level and/or pressure measurement.
* Process connections: Threads, flanges and hygienic connections
* Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
* Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)
* Accuracy: ±0.075%
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
Benefits
* Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation
* Best batch-to-batch repeatability and long-term stability
* Modular concept for easy replacement of display or electronics
* HistoROM/M-DAT data backup for instrument settings and measured values
* Function-monitored from the measuring cell to the electronics
* Seamless and independent system integration (HART/PA/FF)
* International usage thanks to a wide range of approvals
* Best batch-to-batch repeatability and long-term stability
* Modular concept for easy replacement of display or electronics
* HistoROM/M-DAT data backup for instrument settings and measured values
* Function-monitored from the measuring cell to the electronics
* Seamless and independent system integration (HART/PA/FF)
* International usage thanks to a wide range of approvals
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Deltapilot FMB70
|
Measuring Principle
|
Hydrostatic pressure
|
Characteristic
|
Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences Compact version |
Supply Voltage
|
4...20 mA HART
10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex) |
Reference Accuracy
|
Standard 0.1%
Optional 0.075% |
Long Term Stability
|
0.05 % of URL/year
|
Process Temperature
|
-10°C...100°C
(14°F...212°F) |
Ambient Temperature
|
-40°C...85°C
(-40°F...185°F) |
Measuring Cell
|
100 mbar...10 bar
(1.5 psi...150 psi) |
Smallest Calibratable Span
|
25 mbar (3.63 psi)
|
Vacuum Resistance
|
0 mbar abs.
|
Max. Overpressure Limit
|
40 bar (600 psi)
|
Process Connection
|
Thread:
G1 1/2, MNPT1 1/2 Flange: DN40...DN100, ASME 2"...4", JIS 10K |
Material Process Membrane
|
316L, AlloyC,
Gold-Rhodium |
Material Gasket
|
None, measuring cell welded
|
Fill Fluid
|
Inert oil,
Synthetic oil |
Material Housing
|
316L, Die-cast aluminum
|
Communication
|
4 ... 20 mA HART
PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex
|
Safety Approvals
|
SIL
|
Design Approvals
|
EN10204-3.1
NACE MR0175 MR0103 |
Hygienic Approvals
|
3A, EHEDG
CoC ASME-BPE |
Marine Approvals
|
GL, DNV
|
Drinking Water Approvals
|
NSF
|
Specialities
|
Gold-rhodium coated membrane
|
please contact email for more about the shipping cost
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.