Overview
Safe monitoring of flow rates and temperature in hygienic processes. Compact and cost-saving.
Specs at a glance
* Max. measurement error
2% - 10% (per measurement range)
* Measuring range
1"...40"
* Medium temperature range
-20...+85°C
(-4...+185°F)
CIP able to 130°C / 266°F
* Max. process pressure
100 bar (1.740 psi)
2% - 10% (per measurement range)
* Measuring range
1"...40"
* Medium temperature range
-20...+85°C
(-4...+185°F)
CIP able to 130°C / 266°F
* Max. process pressure
100 bar (1.740 psi)
Field of application
The switch is designed for the safe monitoring and display of relative mass flow rates of liquid media in hygienic applications,for example the monitoring of cooling water circulation systems and filter monitoring in the beverage industry. It can be selected between one or two switch outputs as well as one switch output and one standardized analog output for flow rates or temperaturevalues. A variety of hygienic process connections leads to a flexible use.
Flow switch for monitoring and displaying relative mass flow rates of liquid media in the range from 0.03 to 3 m/s (0.1 to 9.84 ft/s). Flowphant T DTT35 − with process connections for hygienic applications.
Application examples:
* Monitoring cooling water circulation systems of pumps, turbines, compressors and heat exchangers
* Leak monitoring in process lines
* Monitoring pump functionality
* Monitoring lubrication systems
* Filter monitoring in the beverage industry
Flow switch for monitoring and displaying relative mass flow rates of liquid media in the range from 0.03 to 3 m/s (0.1 to 9.84 ft/s). Flowphant T DTT35 − with process connections for hygienic applications.
Application examples:
* Monitoring cooling water circulation systems of pumps, turbines, compressors and heat exchangers
* Leak monitoring in process lines
* Monitoring pump functionality
* Monitoring lubrication systems
* Filter monitoring in the beverage industry
Benefits
* Practically no pressure loss
* Configuration software FieldCare for quick configuration and reliable storage of device settings
* Optional: second switch output or 4 to 20 mA analog output for temperature monitoring or for outputting the flow as a percentage
* Function check and process information onsite thanks to digital display at device
* Top housing section which can be rotated 310° and rotatable display make it possible to read the measured values in all orientations
* 3-A approval
* Configuration software FieldCare for quick configuration and reliable storage of device settings
* Optional: second switch output or 4 to 20 mA analog output for temperature monitoring or for outputting the flow as a percentage
* Function check and process information onsite thanks to digital display at device
* Top housing section which can be rotated 310° and rotatable display make it possible to read the measured values in all orientations
* 3-A approval
Specification
item
|
value
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Flowphant T DTT31
|
Type
|
Flow switch
|
Measuring Principle
|
Thermal
|
Product Headline
|
Flow switch for hygenic liquid applications, intelligent / programmable; insertion style
|
Nominal Diameter Range
|
DN 25...1000
|
Measuring Range
|
1"...40"
|
Max. Process Pressure
|
100 bar (1.740 psi)
|
Max. Measurement Error
|
2% - 10% (per measurement range)
|
Medium Temperature Range
|
-20...+85°C
(-4...+185°F) CIP able to 130°C / 266°F |
Degree Of Protection
|
IP66
|
Display/Operation
|
LED
LCD-Display
|
Outputs
|
1 x PNP switchable output + 1 x 4...20 mA analog output
|