Overview
Specs at a glance
* Process temperature
Standard:
-20 ... 100°C
Cleaning:
-20 ... 135°C for 1h
-4 ... 275F for 1h
* Process pressure / max. overpressure limit
Vacuum ... 16 bar
Vacuum ....232 psi
Field of application
Endress+Hauser Capacitance Point Level Detection FTW23 is developed and built for the food industry and meets all international hygiene requirements. The device also fits perfectly for industrial applications in all industries. It is intended for use in applications in liquid media without build-up. The IO-Link capability allows easy parameter setting.
For use in storage tanks, mixing vessels and pipes. For water-based liquids; Ex works for media with dielectric constant > 20,
with adjustment via IO-Link for media with dielectric constant > 1.5 discernible.
* Process connections: Threads
* Temperature: -20 to +100°C (-4 to +212°F), CIP/SIP to 135°C (275°F) for 1 hour
* Pressure: -1 to 16bar abs (-14.5 to 232psi)
* Hygienic certificates
Benefits
* Easy installation thanks to compact design, even in tight conditions or where access is restricted
* IO-Link reduces costs and complexity due to easy configuration of the devices via engineering tools
* CIP and SIP cleanability ensured - up to protection class IP 69
* Individual adjustment to each medium not necessary
* LED display for on-site function check
Specification
item | value |
Grade | Industrial |
Warranty | 1 Year |
Customized support | OEM |
Place of Origin | Germany |
Brand Name | Endress+Hauser |
Measuring Principle | Capacitive Liquid |
Model Number | Liquipoint FTW23 |
Material | Sensor: 316L Sensor isolation: PEEK |
Mode | Capacitance Point Level Detection |
Measuring Principle | Capacitive Liquid |
Characteristic / Application | Compact point level switch for using in water based liquids |
Specialities | CIP and SIP suitable |
Supply / Communication | 10…30 V DC |
Ambient Temperature | -20...70°C -4... 158°F |
Process Temperature | Standard: -20 ... 100°C Cleaning: -20 ... 135°C for 1h -4 ... 275F for 1h |
Process Pressure / Max. Overpressure Limit | Vacuum ... 16 bar Vacuum ....232 psi |
Main Wetted Parts | Sensor: 316L Sensor isolation: PEEK |
Process Connection | Thread G1, G1/2, G3/4, M24 |
Communication | DC PNP IO- Link |
Certificates / Approvals | CSA C/US |
Hygienic Approvals | 3A, EHEDG |
Options | Weld-in adapter, Process adapter for hygienic process connections |
Application Limits | Conductive foam is recognizes as a liquid |
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.