Overview
For use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries.
Specs at a glance
Accuracy
class B acc. to IEC 60751
class A acc. to IEC 60751
class AA acc. to IEC 60751
Response time
depending on configuration
QuickSens: t90 = 1,5 s
StrongSens: t90 = 9,5 s
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
Operating temperature range
PT100 WW:
-200 °C … 600 °C
(-328 °F … 1.112 °F)
StrongSens:
-50 °C … 500 °C
(-58 °F … 932 °F)
QuickSens:
-50 °C … 200 °C
(-58 °F … 392 °F)
PT100 TF:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. immersion length on request
48"
Field of application
It has been designed to meet the requirements of the Food & Beverages and Life Sciences industries and complies with the highest quality standards. It offers a variety of versions within a clearly segmented standard product. The result: Time and cost savings
by simple and fast product selection. It offers many technical innovations: iTHERM QuickSens, StrongSens or QuickNeck. This leads to distinctive reduction of maintenance costs, improved product quality, process efficiency and safety.
Benefits
* User-friendly and reliable from product selection to maintenance
* iTHERM inserts: globally unique, fully-automated production. Full traceability and consistently high product quality for reliable measured values
* iTHERM QuickSens: fastest response times (t90s: 1.5 s) for optimum process control
* iTHERM StrongSens: unsurpassed vibration resistance (> 60g) for ultimate plant safety
* iTHERM QuickNeck – cost and time savings thanks to simple, tool-free recalibration
* iTHERM TA30R: 316L terminal head for easier handling and lower installation and maintenance costs, and with highest IP69K rating
* International certification: explosion protection e.g. ATEX/IECEx/FM/CSA and in compliance with hygiene standards according to 3-A, EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
Specification
Brand Name
|
ENDRESS+HAUSER
|
Model Number
|
TM412
|
Theory
|
Temperature Transmitter
|
Measuring principle
|
Resistance Temperature Detector
|
Measuring range
|
–200 to +600 °C (–28 to +1 112 °F)
|
Pressure range
|
up to 40 bar (580 psi)
|
Protection class
|
up to IP69
|
Accuracy
|
class B acc. to IEC 60751
class A acc. to IEC 60751 class AA acc. to IEC 60751 |
Response time
|
depending on configuration
QuickSens: t90 = 1,5 s StrongSens: t90 = 9,5 s |
Operating temperature range
|
PT100 WW:
-200 °C … 600 °C (-328 °F … 1.112 °F) StrongSens: -50 °C … 500 °C (-58 °F … 932 °F) QuickSens: -50 °C … 200 °C (-58 °F … 392 °F) PT100 TF: -50 °C … 200 °C (-58 °F … 392 °F) |
Characteristic Application
|
imperial style
modular temperature assembly hygienic/aseptic design (3-A®, EHEDG, ASME BPE, FDA) hygienic process connections with neck suitable for hazardous areas incl. protection tube QuickSens for fastest response time StrongSens for most robust design QuickNeck for easy and cost saving recalibration |
Thermowell protection tube
|
without
incl. thermowell incl. Tee-/elbow thermowell |
Insert probe
|
mineral insulated (MI), flexible
pipe version, isolated wires, not flexible |
Outer diameter protection tube Insert
|
1/4'' (6,35 mm)
3/8'' (9,53 mm) 1/2" (12,7 mm) |
Max. immersion length on request
|
48"
|
Material protection tube/ thermowell
|
316L
|
Process connection
|
Weld-in adapter
Tri-clamp Clamp-connections according to ISO2852 G3/4" Liquiphant G1" Liquiphant Varivent T- and elbow thermowell |
Tip shape
|
straight
reduced |
Integration head transmitter
|
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
|
Ex - approvals
|
ATEX II 3 G Ex nA IIC T6, II3D
CSA General Purpose, CSA C/US CSA C/US IS, NI I/1+2/A-D CSA NI I/2/A-D CSA IS, NI I/1+2/A-D FM NI I / 2/A-D FM IS, NI I/1+2/A-D ATEX IECEx II1G Ex ia IIC T6 Ga FM+CSA IS, NI I/1+2/A-D ATEX IECEx II1/2D Ex tb IIIC Da/Db ATEX IECEx II1/2G Ex ia IIC T6 Ga/Gb ATEX IECEx II1/2D Ex ia IIIC Da/Db |
Certification
|
SIL (transmitter only)
|
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.