Overview
* Process pressure / max. overpressure limit :Vacuum ... 100 bar (Vacuum ... 1450 psi)
Benefits
* Reliable and safe measurement due to active build-up compensation
* Reliable and universal application thanks to wide range of certificates and approvals
* Short reaction time
* Material in contact with the process made of corrosion-resistant and FDA-listed materials
* Two-stage overvoltage protection
* No need for recalibration after replacing electronics
Application
For liquids that tend to form build-up. Interface detection of different liquids. Two-point control (pump control) with just one process connection. Foam detection of conductive liquids.
* Process connections: Flanges, threads, special hygienic process connections
* Temperature: -80 to +200°C (-112 to +392°F)
* Pressure: Vacuum to +100bar (vacuum to +1,450psi)
* Sensor length: 6m (20ft)
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval
Specification
|
Measuring principle
|
Capacitive Liquid
|
|
Characteristic / Application
|
Capacitive rod probe
|
|
Specialities
|
Interface detection
Foam detection |
|
Ambient temperature
|
-50 °C ... +70 °C
(-58 °F ... +158 °F) With separate housing: -50 °C ... +120 °C (-58 °F ... +248°F) |
|
Process temperature
|
-80 °C ... +200 °C
(-112 °F ... +392 °F) |
|
Process pressure / max. overpressure limit
|
Vacuum ... 100 bar
(Vacuum ... 1450 psi) |
|
Main wetted parts
|
Insulation material: PTFE, PFA
316L |
|
Process connection
|
G 1/2 ... 1 1/2
NPT 1/2 ... 1 1/2 Flange from DN25.../ASME 1".../JIS 10K... |
|
Process connection hygienic
|
Tri-Clamp ISO2852 gap free plated
Dairy coupling Flush mount |
|
Sensor length
|
Total length of probe: max 6 m (20 ft)
|
|
Communication
|
2- wire 19-253 VAC
3-wire PFM Relay DPDT DC-PNP 8/16 mA |
|
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC
|
|
Safety approvals
|
Overfill prevention WHG
SIL |
|
Design approvals
|
EN 10204-3.1
NACE MR0175 |
|
Marine approval
|
GL/ ABS/ DNV
|
|
Options
|
Inactive length
Fully isolated active build-up compensation Ground tube Separate housing |
|
Components
|
Transmitter
PFM: FTC325, FTC625, FTC470Z, FTC471Z 3-wire: FTC325 |
|
Application limits
|
Notice the pressure and temperature derating.
Notice for non conductive medium the DK. |
Worldwide Shipping
We are proud to offer worldwide shipping to meet your needs, no matter where you are located.
How We Ship
We normally ship via DHL, UPS, or FedEx for fast and trackable delivery.
Flexible Shipping Options
Depending on your order size and timeline, we also support Air Freight and Sea Freight options.
Trade Terms
We can arrange shipments under DAP (Delivered at Place) or DDP (Delivered Duty Paid). Just let us know your preference.
Why Choose Us
With years of experience and long-term cooperation with reliable freight forwarders, we ensure competitive rates and smooth customs clearance.