Overview
Point level detection for fine-grained to coarse-grained bulk solids.
Specs at a glance
* Process temperature
-50°C ... 180°C
(-58°F ... 356°F)
* Process pressure / max. overpressure limit
Vacuum ... 25 bar
(Vacuum ... 362 psi)
-50°C ... 180°C
(-58°F ... 356°F)
* Process pressure / max. overpressure limit
Vacuum ... 25 bar
(Vacuum ... 362 psi)
Field of application
Solicap FTI56 is a fully/partly insulated and robust rope probe for point level detection of fine-grained to coarse-grained bulk solids. It offers maximum reliability and is suited for a wide range of applications thanks to numerous certificates and approvals. Due to its robust construction, it can also be used to provide accurate measurements in applications with very high
tensile loads up to 60kN.
For applications with very high tensile loads up to 60kN. Fieldgate and Solicap represent a solution for material provisioning and logistical optimization (inventory control).
* Process connections: Flanges and threads
* Measurement range: 500 to 22,000mm (20 to 866")
* Temperature: -50 to +180°C (-58 to +356°F)
* Pressure: -1 to +25bar (-14.5 to +363psi)
* International explosion protection certificates, SIL
tensile loads up to 60kN.
For applications with very high tensile loads up to 60kN. Fieldgate and Solicap represent a solution for material provisioning and logistical optimization (inventory control).
* Process connections: Flanges and threads
* Measurement range: 500 to 22,000mm (20 to 866")
* Temperature: -50 to +180°C (-58 to +356°F)
* Pressure: -1 to +25bar (-14.5 to +363psi)
* International explosion protection certificates, SIL
Benefits
* Extremely robust design for harsh process conditions
* Cost savings thanks to easy and fast commissioning as calibration is performed at the press of a button
* Universal application thanks to wide range of certificates and approvals
* Two-stage overvoltage protection against static discharges from the silo
* Increased safety due to permanent automatic monitoring of electronics
* Reduction in storage costs thanks to easy-to-shorten rod model (for partial insulation) and rope model (for partial and full insulation)
* Cost savings thanks to easy and fast commissioning as calibration is performed at the press of a button
* Universal application thanks to wide range of certificates and approvals
* Two-stage overvoltage protection against static discharges from the silo
* Increased safety due to permanent automatic monitoring of electronics
* Reduction in storage costs thanks to easy-to-shorten rod model (for partial insulation) and rope model (for partial and full insulation)
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Solicap FTI56
|
Mode
|
Capacitance Point Level Detection
|
Measuring Principle
|
Capacitive Solid
|
Characteristic / Application
|
Fully / partly isulated rope probe for small-grain / large-grain solids
Simple calibration Suitable for abrasive media Very robust probe |
Specialities
|
Inactive length
High tensile loading Extremely robust probe |
Supply
|
19 ... 253V AC
10 ... 55V DC-PNP 19...253V AC bzw 10...55V DC 8/16mA, 11 ... 36V DC PFM 3-wire |
Ambient Temperature
|
-50°C ... 70°C
(-58°F ... 158°F) |
Process Temperature
|
-50°C ... 180°C
(-58°F ... 356°F) |
Process Pressure / Max. Overpressure Limit
|
Vacuum ... 25 bar
(Vacuum ... 362 psi) |
Main Wetted Parts
|
PTFE, PA, 316L, Steel
|
Max. Tensile Strength
|
60 kN
|
Process Connection
|
Thread R1 1/2, NPT1 1/2
Flanges from DN50.../ASME 2".../JIS... |
Sensor Length
|
0.5m ... 22m
(1.6ft ... 72ft) Inactive length: 0.1m....1m (3"...39") |
Communication
|
2- wire 19-253 VAC
DC PNP Relais DPDT PFM 3-wire 8/16 mA |
Certificates / Approvals
|
ATEX, FM, CSA, IEC Ex, JPN Ex, NEPSI
|
Safety Approvals
|
SIL
|
Components
|
PFM: FTC325, FTC625, FTC470Z, FTC471Z
3-wire: FTC325 |
Application Limits
|
DK min 2
|