Overview
Compact vibration point level switch for liquids especially in the food and life sciences industry.
Specs at a glance
* Process temperature
-50 °C...+150 °C
(-58 °F...+302 °F)
* Process pressure / max. overpressure limit
Vacuum...64 bar
(Vacuum...928 psi)
* Min. density of medium
0.5g/cm³
(0.4g/cm³ optional)
-50 °C...+150 °C
(-58 °F...+302 °F)
* Process pressure / max. overpressure limit
Vacuum...64 bar
(Vacuum...928 psi)
* Min. density of medium
0.5g/cm³
(0.4g/cm³ optional)
Field of application
Liquiphant FTL50H is a point level switch for use in hazardous areas with all international certificates. Especially useable in the food and life sciences industry with hygienic certificates (3-A, EHEDG, ASME BPE). FTL50H offers functional safety SIL2/SIL3.
Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Point level switch for all liquids with completely welded housing concept.
* Process connections: Threads, flanges and hygienic process connection (Tri-Clamp, dairy coupling, aseptic, DRD, SMS, Varivent)
* Temperature: -50 to +150°C (-58 to +302°F)
* Pressure: -1 to +64bar (-14.5 to +928psi)
* Sensor material: 316L
* International explosion protection certificates, overfill protection WHG, SIL, hygienic certificates, marine approvals
Reliable measurement values, not affected by: changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Point level switch for all liquids with completely welded housing concept.
* Process connections: Threads, flanges and hygienic process connection (Tri-Clamp, dairy coupling, aseptic, DRD, SMS, Varivent)
* Temperature: -50 to +150°C (-58 to +302°F)
* Pressure: -1 to +64bar (-14.5 to +928psi)
* Sensor material: 316L
* International explosion protection certificates, overfill protection WHG, SIL, hygienic certificates, marine approvals
Benefits
* International hygienic certificates (3-A, EHEDG, ASME BPE). FDA-conformed material
* Electro-polished and passivated surface finishing
* International explosion protection certificates and overfill protection certificate (WHG)
* No mechanically moving parts: no maintenance, no wear, long operating life.
Monitoring of fork for damage: guaranteed function
* Use in safety systems requiring functional safety to SIL2/SIL3 in accordance with
IEC 61508/IEC 61511-1
* No calibration required, easy to start up
* Variety of standardized hygienic process connections for hygiene sensitive applications
* Electro-polished and passivated surface finishing
* International explosion protection certificates and overfill protection certificate (WHG)
* No mechanically moving parts: no maintenance, no wear, long operating life.
Monitoring of fork for damage: guaranteed function
* Use in safety systems requiring functional safety to SIL2/SIL3 in accordance with
IEC 61508/IEC 61511-1
* No calibration required, easy to start up
* Variety of standardized hygienic process connections for hygiene sensitive applications
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Liquiphant FTL50H
|
Material
|
316L
|
Mode
|
Point Level Switch
|
Measuring Principle
|
Vibration Liquids
|
Characteristic / Application
|
Premium device for point level detection
in hygienic/aseptic applications. Focus Food & Beverage and Life Sciences. Compact sensor version, Modular & completely welded housing concept, Wide range of certificates. |
Specialities
|
Plug and play functionalities,
Surface finish: mechanical or electro-polished, Density/Concentration measurement, SIL 2/3 according to IEC 61508 |
Supply / Communication
|
PROFIBUS PA,
19 ..253V AC, 10...55V DC-PNP, 19...253V AC or 19...55V DC with relay DPDT, 8/16mA, NAMUR, PFM |
Ambient Temperature
|
-50°C ... 70°C
(-60°F ... 160 °F) |
Process Temperature
|
-50 °C...+150 °C
(-58 °F...+302 °F) |
Process Pressure / Max. Overpressure Limit
|
Vacuum...64 bar
(Vacuum...928 psi) |
Min. Density Of Medium
|
0.5g/cm³(0.4g/cm³ option)
|
Main Wetted Parts
|
316L
|
Process Connection
|
Threads (for weld-in adapter):
G3/4A, G1A. Flange: DN25...DN100 ASME 1"...4", JIS 25A...100A |
Process Connection Hygienic
|
Tri-Clamp,
DIN 11851, DIN11864-1 Ingold, Flush mount, DRD, SMS1145, Varivent (Varinline) |
Sensor Length
|
Compact sensor
|
Communication
|
PROFIBUS PA
|
Certificates / Approvals
|
ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
|
Safety Approvals
|
Overfill protection WHG,
SIL 2/ SIL 3 |
Design Approvals
|
Inspection certificate 3.1, EN10204,
CoC ASME BPE, Conformity to cGMP, EU Food Contact Material (EC) 1935/2004, US Food Contact Material FDA CFR 21, CN Food Contact Material GB 4806, Declaration of Conformity ASME B31.3, AD2000, CRN approval |
Hygienic Approvals
|
3-A,
EHEDG, CoC-ASME BPE |
Marine Approval
|
GL/ ABS/ DNV
|
Options
|
Customized settings (Density)
|
Components
|
FTL325P/FTL375P Interface PFM
FTL325N/FTL375N Interface NAMUR |
Successor
|
FTL63
|
please contact email for more about the shipping cost
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.