Endress+Hauser 6F3B Flow Measurement Proline T-Mass F300 Thermal Mass Flowmeter

: In stock

: Flow Measurement

: Endress+Hauser

Regular price Sale

OverviewEndress Hauser Proline Promass F300 Coriolis Flowmeter is an inline flowmeter with long-term stability and a compact, easily accessible transmitter.Specs at a glance * Max. measurement error Gas: 1.0%...

Overview

Endress Hauser Proline Promass F300 Coriolis Flowmeter is an inline flowmeter with long-term stability and a compact, easily accessible transmitter.

Specs at a glance

 * Max. measurement error Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
 * Measuring range :0.5 to 3750 kg/h (1.1 to 8250 lb/h)

 * Medium temperature range :-40 °C to +180°C (-40 °F to +356 °F)
 * Max. process pressure : PN40 / Cl. 300 / 20K
 * Wetted materials
  Measuring tubes
   DN 15 to 50 (½ to 2"): stainless cast steel, CF3M/1.4408
   DN 65 to 100 (2½ to 4"): stainless steel, 1.4404 (316/316L)
  Process connections
   Flange connections:Stainless steel, 1.4404 (F316/F316L)
   Threaded connections:Stainless steel, 1.4404 (316/316L)
   Sensing elementUnidirectional
   Stainless steel, 1.4404 (316/316L) Alloy C22, 2.4602 (UNS N06022);
   Bidirectional   Stainless steel, 1.4404 (316/316L)
   Reverse flow detection   Stainless steel, 1.4404 (316/316L)

 

Benefits

 * Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
* High level of process control – premium measurement accuracy and repeatability
* Reliable monitoring – detection of process disturbances and reverse flow
* Easy maintenance – removable sensor
* Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology

Application

The patented sensor design of t-mass F provides unprecedented measurement stability in thermal inline mass flow measurement. It compensates in real time for changes of process conditions: temperature, pressure, flow direction and gas type. Its compact
transmitter offers high flexibility in terms of operation and system integration: access from one side, remote display and improved connectivity options. Heartbeat Technology enables measurement reliability and compliant verification.
* Measuring principle is characterized by a high operable flow range and direct mass flow measurement
* Measurement of utility and process gases as well as gas mixtures in small line sizes Device properties
* Inline version with DN 15 to 100 (1/2 to 4")
* Bidirectional measurement; high measuring performance
* Patented drift-free sensor with SIL 2
* Compact dual-compartment housing with up to 3 I/Os
* Backlit display with touch control and WLAN access
* Remote display available

Specification

Measuring principle Vortex
Product headline Versatile flowmeter with detection of wet steam conditions and best-in-class accuracy.
Easy energy management – integrated temperature and pressure measurement for steam and gases.
Suitable for a wide range of applications; optimized for steam applications.
Sensor features Space-saving engineering – inlet run compensation. Same accuracy down to Re 10 000 – most linear Vortex meter body. Long-term
stability – robust drift-free capacitive sensor.
Wet steam capabilities for DN 25 to 300 (1 to 12"). Flexible positioning of pressure cell. Industrial siphon design for pressure
measurement.
Transmitter features Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch
control, background lighting. Integrated verification – Heartbeat Technology.
Display module with data transfer function. Robust dual-compartment housing. Plant safety: worldwide approvals (SIL, Haz. area).
Nominal diameter range DN 15 to 300 (½ to 12")
Wetted materials Measuring tube: 1.4408 (CF3M); CX2MW similar to Alloy C22, 2.4602
DSC sensor: 1.4404 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
Process connection: 1.4404/F316/F316L); 2.4602
Measured variables Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperatur
Max. measurement error Volume flow (liquid): ±0.75 %
Volume flow (optional): ±0.65 %
Volume flow (steam, gas): ±1.00 %
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure
compensation)
Mass flow (liquid): ±0.85%
Measuring range Liquid: 0.076 to 2100 m³/h (0.045 to 1300 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 0.39 to 28000 m³/h (0.23 to 17000 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
Max. process pressure PN 100, Class 600, 20K
Medium temperature range Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
Ambient temperature range Compact version (standard): –40 to +80 °C (–40 to +176 °F)
Compact version (option): –50 to +80 °C (–58 to +176 °F)
Remote version (standard): –40 to +85 °C (–40 to +185 °F)
Remote version (option): –50 to +85 °C (–58 to +185 °F)
Sensor housing material Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M)
Transmitter housing material AlSi10Mg, coated; 1.4404 (316L)
Degree of protection Compact version: IP66/67, type 4X enclosure
Sensor remote version: IP66/67, type 4X enclosure
Transmitter remote version: IP66/67, type 4X enclosure
Display/Operation 4‐line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible
Remote display available
Outputs 4‐20 mA HART (passive)
4‐20 mA (passive)
Pulse/frequency/switch output (passive)
Inputs Current Input 4‐20 mA (passive)
Digital communication HART, PROFIBUS PA, FOUNDATION Fieldbus
Power supply  DC 12 to 35 V (4‐20 mA HART with/without pulse/frequency/switch output)
DC 12 to 30 V (4‐20 mA HART, 4‐20 mA)
DC 12 to 35 V (4‐20 mA HART, pulse/frequency/switch output, 4‐20 mA input)
DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
Hazardous area approvals ATEX, IECEx, cCSAus, JPN, EAC
Product safety CE, C-TICK, EAC, UK Ex
Functional safety Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
(TÜV SÜD attestation)
Marine approvals and certificates ABS, LR, BV, DNV
Pressure approvals and certificates PED, CRN, AD 2000
Material certificates 3.1 material
NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614‐1, similar to ASME IX (on request)
please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.