Endress+Hauser Gauge Pressure Cerabar PMC11

: In stock

: Pressure Measurement

: Endress+Hauser

Regular price Sale

Overview Cost-effective pressure transducer with ceramic sensor for measurement in gases or liquids. Specs at a glance  * Accuracy :0.5% * Process temperature : -25 °C…+85 °C (-13 °F…+185 °F) *...


Overview

Cost-effective pressure transducer with ceramic sensor for measurement in gases or liquids.

Specs at a glance

 * Accuracy :0.5%
 * Process temperature : -25 °C…+85 °C (-13 °F…+185 °F)
 * Pressure measuring range : +400 mbar…+40 bar(+6 psi...+600 psi)
 * Measuring cell : +400 mbar…+40 bar (+6 psi...+600 psi)


Benefits

 * Easy and time-saving installation and set up within the plant due to very compact construction and customizable measuring ranges
* Reference accuracy of 0.5% together with high long- term stability and repeatability ensures a high quality of processmonitoring in standard processes
* Capacitive oil-free measuring cell with high abrasion resistance and 100% test coverage during production guarantees long process availability

Application

SpecificationThe Cerabar PMC11 is the most price-attractive compact pressure transmitter in its segment. It features a capacitive, oil-free ceramic sensor and is able to measure gauge pressure from 400mbar up to 40bar. The PMC11 is designed for standard applications in
the process industry and to withstand the conditions with the use of high quality materials like 316L and 99,9% Al2O3.
Pressure transducer with oil-free ceramic sensor to measure gauge pressure in gases or liquids.
* Process connections: Threads
* Process temperature: -25 to +85°C (-13 to +185°F)
* Process pressure: 400mbar to +40bar (6 to 600psi)

* Accuracy: ±0.5% of span

Specification

Measuring principle
Gauge pressure
Characteristic
Cost effective pressure transducer, capacitive sensor with ceramics measuring diaphragm
Supply voltage
Analogue output: 10…30 VDC
0...10 V output: 12…30 VDC
Reference Accuracy
0.5 %
Long term stability
0.2 % of URL/year
Process temperature
-25 °C…+85 °C
(-13 °F…+185 °F)
Ambient temperature
-40 °C…+70 °C
(-40 °F…+158 °F)
Measuring cell
+400 mbar…+40 bar
(+6 psi...+600 psi)
Max. overpressure limit
max. 60 bar (900 psi)
Process connection
Threads:
G1/4, G1/2,
MNPT 1/4, MNPT 1/2,
DIN13
Communication
4...20 mA
0...10 V
Design approvals
EN10204-3.1 Final inspection report
Cleaned from oil and grease
please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,

some country could not be ship by above method, then we would use EMS or Country Logistics line.