Overview
Transmitter in housing for field or top hat rail mounting for up to 2 sensors FDU90/91/92/93/95
Application
Field of Prosonic FMU90 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids. Also the flow measurement in open channels and weirs is possible as the simultaneous measurement of level and flow in a storm water overflow basin with only 1 sensor. Up to 6 relays for tendency alarm, flow pulse output or backwater/sludge alarm, 1 or 2 channel version.
Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection.
Pump control, rake control and as option: additional pump control function.
* Calculations: Average, difference, sum
* Application flow: Flow measurement in open channels and weirs with 1 or 2 sensors
* Flow measurement with back water or sludge detection
* Up to 3 totalizers and 3 counters
* Counting or time pulse output for control of external units
Benefits
* Envelope curves on the display for quick and simple diagnosis
* Easy operation, diagnosis and measuring point documentation with the supplied "FieldCare" operating program
* Time-of-Flight correction via integrated or external temperature sensors
* Linearisation (up to 32 points, freely configurable) for the most common flumes and weirspre-programmed and selectable
* Online calculation of the flume-/weir-flows via integrated flow curves
* Automatic detection of the sensors FDU9x
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
endress+hauser
|
Model Number
|
Prosonic FMU90
|
Material
|
PVDF
|
Mode
|
Ultrasonic measurement Time-of-Flight
|
Measuring Principle
|
Ultrasonic
|
Characteristic / Application
|
Separated version with Field housing or top hat rail housing for control cabinet instrumentation, up to 6 relays for pump / rake /
limit control, 1 or 2 channel version |
Specialities
|
Protection Class IP 66 / NEMA 4x
automatic sensor recognition of FDU9x sensors option: flow measurement for open channel and weirs or additional pump control functions |
Supply / Communication
|
90 ... 253 VAC
10.5 ... 32 VDC up to 2x 4...20mA HART Profibus DP |
Accuracy
|
+/- 2mm + 0.17% of measured distance
|
Ambient Temperature
|
-40 °C ... 60 °C
(-40 °F ... 140 °F) |
Communication
|
up to 2x 4 ... 20 mA HART
Profibus DP |
Certificates / Approvals
|
ATEX, CSA
|
Options
|
Illuminated display, 6 line graphic display with country specific menu guidance, on-site diagnosis with envelope curve on display
|
Components
|
Sensors FDU9x
|
We normally ship by DHL, UPS, FEDEX or TNT,
some country could not be ship by above method, then we would use EMS or Country Logistics line.