Endress+Hauser Radar Measurement Micropilot FMR532

: In stock

: Level Measurement

: Endress+Hauser

Regular price Sale

Overview For high accurate non-contact level measurement in stilling well applications in custody transfer. Specs at a glance * Accuracy+/- 1 mm, custody transfer* Process temperature-40 °C ......

Overview

For high accurate non-contact level measurement in stilling well applications in custody transfer.
Specs at a glance

* Accuracy
+/- 1 mm, custody transfer
* Process temperature
-40 °C ... 150 °C
(-40 °F ... 302 °F)
* Process pressure / max. overpressure limit
Vacuum ... 25 bar
(Vaccum ... 362 psi)
* Max. measurement distance
40 m (131 ft)
* Main wetted parts
316L + PTFE

Field of application

The Micropilot FMR532 is used for custody transfer and inventory control applications with NMi- and PTB-approvals. It meets the relevant requirements according to OIML R85 and API 3.1B. The FMR532 free space radar with planar antenna is specifically suited for stilling well applications. Micropilot FMR532 offers cost-effective and simple installation via 4-wire cable with HART and 24
V DC intrinsically safe power supply.

With planar antenna particularly suited for stilling well applications with ranges up to 38m (124ft).
* Process connection: Flange
* Temperature: -40 to +150°C (-40 to +302°F)
* Pressure: Vacuum to +25bar (Vacuum to +362psi)
* Maximum measuring range: 38m (124ft)
* Accuracy: Better than ±1mm
* C-band: 6GHz
* International explosion protection and custody transfer certificates, overfill prevention WHG, SIL, marine approval

Benefits

 * 0.8mm accuracy (2σ value)
* National approvals (NMi, PTB) for custody transfer
* Applicable as stand-alone system or integrated into tank gauging systems via the Tank Side Monitor NRF590
* Easy on-site operation via menu-driven alphanumeric display
* Easy commissioning, documentation and diagnostics via FDT/DTM technology (FieldCare)
* Cost-effective and simple installation via 4-wire cable with HART and 24 V DC intrinsically safe power supply
* Unique drip-off antenna design eliminates measurement error due to condensation build-up

Specification


item
value
Grade
Industrial
Warranty
1 Year
Customized support
OEM
Place of Origin
Germany
Brand Name
Endress+Hauser
Model Number
Micropilot FMR532
Measuring Principle
Level radar
Supply / Communication
4-wire (HART)
Frequency
C-band (~6 GHz)
Accuracy
+/- 1 mm, custody transfer
Ambient Temperature
Standard:
-40 °C ... 80 °C
(-40 °F ... 176 °F)
For calibration to regulatory standards:
-25 °C ... 60 °C
(-13 °F ... 131 °F)
Process Temperature
-40 °C ... 150 °C
(-40 °F ... 302 °F)
Process Pressure / max. Overpressure Limit
Vacuum ... 25 bar
(Vaccum ... 362 psi)
Main Wetted Parts
316L + PTFE
Process Connection
DN150 ... DN300 / 6" ... 12"
Max. Measurement Distance
40 m (131 ft)
Communication
4 ... 20 mA
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, NEPSI
Design Approvals
EN 10204-3.1
NACE MR0175, MR0103
Marine Approval
GL/ ABS
Application Limits
Maximum measuring range is dependent on the tank form and/or application
Free space and many baffles
FMR540


please contact email for more about the shipping cost

We normally ship by DHL, UPS, FEDEX or TNT,