Overview
Point level switch for liquids with highly corrosion-resistant coating.
Specs at a glance
* Process temperature
-50 °C...+150 °C
(-58 °F...+302 °F)
up to 230 °C / 450°F on request
* Process pressure / max. overpressure limit
Vacuum...40 bar
(Vacuum...580 psi)
* Min. density of medium
0.5g/cm³ (0.4g/cm³ optional)
-50 °C...+150 °C
(-58 °F...+302 °F)
up to 230 °C / 450°F on request
* Process pressure / max. overpressure limit
Vacuum...40 bar
(Vacuum...580 psi)
* Min. density of medium
0.5g/cm³ (0.4g/cm³ optional)
Field of application
Liquiphant FTL51C is a point level switch with extension tube and highly corrosion resistant coating. For use in hazardous areas with all international certificates. Useable in all industries. FTL51 offers functional safety SIL2/SIL3. With the second line of defense highest degree of safety and availability of the device can be guaranteed. Reliable measurement values, not affected by:
changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Point level switch for all liquids with highly corrosion-resistant coating.
* Process connections: Flanges and hygienic process connection (FDA conform with PFA)
* Temperature: -50 to +150°C (-58 to +302°F)
* Pressure: -1 to +40bar (-14.5 to +580psi)
* Sensor material: ECTFE, PFA (Edlon, Rubyred, conductive), Enamel
* International explosion protection certificates, overfill protection WHG, SIL, hygienic certificates, marine approvals
changing media properties, flow, turbulences, gas bubbles, foam, vibrations or build-up.
Point level switch for all liquids with highly corrosion-resistant coating.
* Process connections: Flanges and hygienic process connection (FDA conform with PFA)
* Temperature: -50 to +150°C (-58 to +302°F)
* Pressure: -1 to +40bar (-14.5 to +580psi)
* Sensor material: ECTFE, PFA (Edlon, Rubyred, conductive), Enamel
* International explosion protection certificates, overfill protection WHG, SIL, hygienic certificates, marine approvals
Benefits
* Use in safety systems requiring functional safety to SIL2/SIL3 in accordance with IEC 61508/IEC 61511-1
* Different plastic coating (PFA) and enamel coating for applications with aggressive medias
* International explosion protection certificates and overfill protection certificate (WHG)
* No calibration required, easy to start up
* No mechanically moving parts: no maintenance, no wear, long operating life. Monitoring of fork for damage: guaranteed function
* Second line of defense to protect the environment
* Variety of standardized process connections for all applications
* Different plastic coating (PFA) and enamel coating for applications with aggressive medias
* International explosion protection certificates and overfill protection certificate (WHG)
* No calibration required, easy to start up
* No mechanically moving parts: no maintenance, no wear, long operating life. Monitoring of fork for damage: guaranteed function
* Second line of defense to protect the environment
* Variety of standardized process connections for all applications
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Liquiphant FTL51C
|
Material
|
ECTFE
PFA (Edlon) PFA (Rubyred) PFA (conductive) Enamel |
Mode
|
Point Level Switch
|
Measuring Principle
|
Vibration Liquids
|
Characteristic / Application
|
High protection against aggressive media by using antistatic coating
Modular housing concept wide range of process connections Analogue and bus interfaces Extensive certificate range (e.g.Ex,WHG) pipe extension up to 3m (6m option) |
Specialities
|
Foamdetection
Detekt a densitychange second line of defense |
Supply / Communication
|
PROFIBUS PA
19...253V AC, 2-wire 10...55V DC-PNP, 3-wire DPDT, 19...253V AC, 10...55V DC 8/16mA, 11...36V DC NAMUR PFM, 2-wire NAMUR with testbutton |
Ambient Temperature
|
-50 °C...+70 °C
(-58 °C...+158 °F) |
Process Temperature
|
-50 °C...+150 °C
(-58 °F...+302 °F) up to 230 °C / 450°F on request |
Process Pressure / Max. Overpressure Limit
|
Vacuum...40 bar
(Vacuum...580 psi) |
Min. Density Of Medium
|
0.5g/cm³(0.4g/cm³ optional)
|
Main Wetted Parts
|
ECTFE
PFA (Edlon) PFA (Rubyred) PFA (conductive) Enamel |
Process Connection
|
Flange:
DN25...DN100, ASME 1"...3", JIS RF10 K 50 |
Process Connection Hygienic
|
FDA conform with PFA (Edlon)
|
Sensor Length
|
ECTFE, PFA 130mm, 148mm...3000mm
(ECTFE, PFA 5.12", 5.83"...118") Enamel 130mm, 148mm...1200mm (Enmal 5.12", 5.83"...47.24") |
Communication
|
PROFIBUS PA
19...253V AC 10...55V DC-PNP 19...253V AC bzw 10...55V DC 8/16mA, 11...36V DC NAMUR PFM |
Certificates / Approvals
|
ATEX, FM, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
|
Safety Approvals
|
SIL2/ SIL3
|
Design Approvals
|
EN 10204-3.1
|
Marine Approval
|
GL/ ABS/ DNV
|
Options
|
Heavy duty stainless steel housing mainly for the oil and gas industry
|
Components
|
FTL325P/FTL375P Interface PFM
FTL325N/FTL375N Interface NAMUR |
please contact email for more about the shipping cost