Benefits
*Continually monitor meter health and performance without stopping the process with Smart Meter Verification
* Prevent moisture ingress with dual-compartment transmitter housing
* Improve process management with advanced Digital Signal Processing
* Optimize control in noisy applications with High Process Noise diagnostic and Selectable Coil Drive Frequency options
* Tunable Empty Pipe diagnostic minimizes issues and false readings when the pipe is empty
* Quickly verify installation integrity with Ground and Wiring Fault Detection diagnostic
* Simplify adjustments in hazardous environments without removing the cover using optical switches for configuration
* Universal transmitter capabilities enable reduced inventory and consistent interface for any magnetic flow meter sensor
Specification
Item
|
value
|
Warranty
|
1 Year
|
Customized support
|
OEM, ODM, OBM
|
Place of Origin
|
United States
|
Brand Name
|
ROSEMOUNT
|
Model Number
|
8732E
|
Type
|
Electromagnetic meters Magnetic Flow Meter Transmitters
|
Power supply
|
90-250VAC, 50/60Hz or 12- 42VDC
|
Sensor compatibility
|
Compatible with Rosemount 8705, 8711, and 8721sensors. Compatible with AC and DC powered sensors ofother manufacturers.
|
Transmitter coil drive current
|
500mA
|
Flow rate range
|
Capable of processing signals from fluids that are travelingbetween 0.04 and 39 ft/s (0.01 to 12 m/s) for both forwardand reverse
flow in all sensor sizes. Full scale continuouslyadjustable between –39 and 39 ft/s (–12 to 12 m/s). |
Conductivity limits
|
Process liquid must have a conductivity of5 microSiemens/cm (5 micromhos/cm) or greater.
|
Line power fuses
|
90-250VAC systems
1A, 250V, I2t, 1.5 A2s Rating, Fast ActingBussman AGC-1, Littlefuse 31201.5HXP 12-42VDC systems 3 Amp, 250V, I2t, 14 A2s Rating, Fast ActingBel Fuse 3AG 3-R, Littelfuse 312003P, Schurter 0034.5135 |
Line power fuses
|
15W maximum - DC
40VA maximum - AC |
Switch-on current
|
AC: Maximum 35.7A (< 5ms) at 250VAC
DC: Maximum 42A (< 5ms) at 42VDC |
We normally ship by DHL, UPS, FEDEX or TNT,