VEGA VEGAMIP R62 level detection of bulk solids and liquids

: In stock

: Level Measurement

: VEGA

Regular price Sale

Overview  VEGAMIP R62Microwave receiver in separate version for level detection of bulk solids and liquidsMicrowave receiver, detached version Application The non-contact measuring method has no direct contact with...

Overview 

VEGAMIP R62
Microwave receiver in separate version for level detection of bulk solids and liquids
Microwave receiver, detached version

Application

The non-contact measuring method has no direct contact with the medium and thus warranties continuous, wear and maintenance free operation. Detached version for use in poorly accessible or dangerous mounting locations.
The VEGAMIP R62 is the receiving unit of the microwave emitter VEGAMIP T61 in separate version for level detection of bulk solids and liquids. Typical applications are the detection of bulk solids in silos, bunkers and crushers as well as liquids in tubes and vessels. The non-contact measuring principle has no direct contact to the medium and guarantees wear and maintenance-free permanent operation.
 

Benefits

* Separate instrument version enables mounting in installation positions difficult to access
* Reliable measurement even with very abrasive products
* Reliable measurement even with changing product features

Specification 

item
value
Grade
Industrial
Warranty
1 Year
Customized support
OEM, ODM, OBM
Place of Origin
Germany
Brand Name
VEGA
Model Number
VEGAMIP R62
Measuring range - Distance
 * 100 m [Meter - Foot]
Process temperature
 * -40 ... 80 °C [°C - °F]
Process pressure
 * -1 ... 4 bar [Bar - kPa - psi]
Version
 * hygienically encapsulated horn antenna
* for separate horn antenna
* with horn antenna ø 40 mm
* with horn antenna ø 48 mm
* with horn antenna ø 75 mm
* with horn antenna ø 95 mm
* with plastic horn antenna ø 80 mm
* Horn antenna ø 1½"
* with encapsulated horn antenna
Materials, wetted parts
 * PTFE
* 316L
* 1.4848
* PP
Threaded connection
  * G1½, 1½ NPT
Flange connection
 * ≥ DN50, ≥ 2"
Hygenic fittings
  * Slotted nut ≥ 2", DN50 - DIN 11851
* Varivent ≥ DN25
* DRD connection ø 65 mm
* for NEUMO BioControl D50 PN16 / 316L
Seal material
 * FKM
* FFKM
Housing material
  * Plastic
* Aluminium
* Stainless steel (precision casting)
* Stainless steel (electropolished)
Protection rating
 * IP66/IP68 (0,2 bar)
* IP66/IP67
Ambient temperature
 * -40 ... 80 °C


please contact email for more about the shipping cost