Overview
Product overview: Fluke 717 Pressure Calibrator
The Fluke 717 Pressure Calibrator delivers outstanding performance, durability and reliability. The calibrator is compact, lightweight, and easy to carry. With a push button interface similar to the multifunction Fluke 750 Series Documenting Process Calibrators, the Fluke 717 Pressure Calibrator is easy to use. It is EMI tolerant, dust and splash resistant, and features a removable battery door for quick battery changes. The Fluke 717 Pressure Calibrator is compatible with Fluke 700Pxx differential, gauge and absolute pressure modules to increase functionality.
Special features
- Large backlit dual display shows any combination of T1, T2 (52 and 54 only), T1-T2 (52 and 54 only), plus MIN, MAX, or AVG
- Recall function allows logged data to be easily reviewed on the meter display
- Infrared USB communication port allows data to be exported to optional FlukeView Forms® Temperature PC software for further analysis and graphing
- Data Logging up to 500 points of data with user adjustable recording interval
- Relative time clock on MIN, MAX, and AVG provides a time reference for major events
- Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
- Measures J, K, T, E, R, S, and N-type thermocouples
- Readout in °C, °F, or Kelvin (K)
- Splash and dust resistant case protected by impact absorbing holster
- User-friendly front panel is easy to set up and operate
- Sleep mode increases battery life; typical 1000-hour battery life
- Battery door allows easy battery replacement without breaking the calibration seal
- Optional ToolPak accessory allows the thermometer to hang from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation
- 3 year warranty
Models: 54 II B Data Logging Thermometer with Dual Input
Fluke 54 II B dual input digital thermometer can log up to 500 points of data to internal memory. Fast response and laboratory accuracy (0.05% + 0.3 °C).
UPC#: 0 95969 56511 0
Fluke 54 II Dual Input Digital Thermometer
UPC#: 0 95969 06895 6
Includes:
- Impact absorbing holster
- Two 80PK-1 bead probe thermocouples
Specification
| General Specifications | ||
| Temperature accuracy | Above -100°C | J, K, T, E, and N-type: ±[0.05% + 0.3°C]1 |
| R and S-type: ±[0.05% + 0.4°C]1 | ||
| Below -100°C | J, K, E, and N-types: ±[0.20% + 0.3°C]1 | |
| T-type: ±[0.50% + 0.3°C] | ||
| Temperature | J-type | -210°C to 1200°C |
| K-type | -200°C to 1372°C | |
| T-type | -250°C to 400°C | |
| E-type | -150°C to 1000°C | |
| N-type | -200°C to 1300°C1 | |
| R and S-type | 0°C to 1767°C1 | |
| Temperature scale | ITS-90 | |
| Applicable standards | NIST-175 | |
| Display resolution | 0.1°C, 0.1 K < 1000 | |
| 1°C, 1 K ≥ 1000 | ||
| 1. Only the Fluke Models 53 II B and 54 II B thermometers are capable of measuring N, R, and S-type thermocouples. | ||
| Environmental Specifications | ||
| Operating temperature | -10°C to 50°C | |
| Storage temperature | -40°C to 60°C | |
| Humidity (without condensation) | 0% to 90%; 0°C to 35°C | |
| 0% to 70%; 0°C to 50°C | ||
| Safety Specifications | ||
| Overvoltage category | CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 | |
| Agency approvals | CE, CSA, TÜV (pending) | |
| Mechanical and General Specifications | ||
| Size (L x W x D) | 173 x 86 x 38 mm | |
| Weight | 400 g | |
| Batteries | 3 AA batteries; typical 1000-hour life | |