Overview
HygienicMaster FEH610 is designed specifically for the food & beverage industries in a cost-effective, robust package.
The sensor is fully CIP/SIP cleanable, manufactured from FDA approved materials and certified with 3A.
Available as an integral or remote mount design – with or without local LCD display. All versions use a common transmitter with easy to understand diagnostic message for improved operator efficiency.
HygienicMaster FEH610´s variable process connections simplify installation and reduce inventory and replacement costs.
HygienicMaster FEH610 is ideally suited for hygienic standard applications featuring all functions required - no more and no less.
The perfect device for everyday applications.
Simple and economical.
- Field-proven powerful and flexible transmitter technology
– ABB common HMI concept
– Easy Set-up function for simple and intuitive configuration
– Through-the-glass operation - One single transmitter for all design types
– Integral mount design or remote mount design
– With or without local LCD display
– Universal wide range power supply
– 1 analog output, 2 digital outputs - Robust construction for rough environmental conditions
– Hermetically sealed flow sensor
– Protection of the inside components against
Condensation, vibration and corrosion
Damages during transport and mounting
Benefits
-
Hygienic and Reliable Measurement
Designed for applications requiring strict hygiene standards and reliable flow measurement. -
Easy Cleaning and Maintenance
Supports hygienic process requirements including CIP/SIP cleaning procedures. -
Cost-Effective Hygienic Solution
Provides reliable performance for standard food, beverage and pharmaceutical applications. -
Flexible Installation
Multiple hygienic connection options simplify integration into process systems. -
Reduced Maintenance Effort
No moving parts design minimizes wear and improves long-term reliability. -
Stable Process Control
Provides consistent measurement performance for conductive liquids.
Specification
| item | value | |
|---|---|---|
| accuracy | ±0.5% of rate | |
| type | Hygienic Electromagnetic Flowmeter | |
| brand name | ABB | |
| model number | FEH610 | |
| measurement type | Magnetic Inductive Flow Measurement | |
| measurement media | Conductive Liquids | |
| flow measurement | Volume Flow Measurement of Hygienic Liquid Media | |
| measuring principle | Faraday's Law of Electromagnetic Induction | |
| nominal diameter | DN 3 to DN 100 (1/8 to 4 in.) | |
| output signal | 4 to 20 mA; Pulse/Frequency Output | |
| communication protocols | HART (Configuration Dependent) | |
| display | LCD Graphic Display (Optional) | |
| display technology | Through-The-Glass (TTG) Operation | |
| local operation | Configuration via Local Display and Touch Control (Configuration Dependent) | |
| electronics | Modular Transmitter Design | |
| transmitter design | Compact Mount or Remote Mount Version | |
| diagnostics | Basic Device Diagnostics; Empty Pipe Detection | |
| process connection | Hygienic Connections: Tri-Clamp, Threaded Connections, Welded Ends and Other Hygienic Options | |
| liner material | PFA | |
| electrode materials | Configuration Dependent | |
| fluid temperature | Up to 140 °C (284 °F) (Configuration Dependent) | |
| pressure rating | Configuration Dependent | |
| protection rating | IP67 / IP68 |