Endress+Hauser Radar Measurement Time-of-Flight Micropilot FMR52

: В наличии

: Level Measurement

: Endress+Hauser

Обычная цена Распродажа

Overview For level measurement in aggressive liquids or applications with hygiene requirements. Specs at a glance * Accuracy+/- 2 mm (0.08 in)* Process temperature-196...+200 °C(-321...+392 °F)* Process pressure...


Overview

For level measurement in aggressive liquids or applications with hygiene requirements.
Specs at a glance
* Accuracy
+/- 2 mm (0.08 in)
* Process temperature
-196...+200 °C(-321...+392 °F)
* Process pressure / max. overpressure limit
-Vacuum...25 bar (Vacuum...363 psi)
* Max. measurement distance
Standard: 40 m (131 ft)
With advanced dynamics: 60 m (197 ft)
* Main wetted parts
PTFE

Application

For applications in aggressive liquids Micropilot FMR52 offers extraordinary advantages with its completely PTFE-filled and flush-mounted horn antenna. The FMR52 is also the sensor for hygiene-sensitive applications in the food and life sciences industry - ASME BPE, USP Class VI, 3-A and EHEDG approvals. Micropilot is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Flush-mounted, completely PTFE-encapsulated horn antenna.
* Process connections: Flush-mounted with cladded flange, process connections for hygiene requirements (Tri-Clamp, 11851)
* Temperature: -196 to +200°C (-320,8 to +392°F)
* Pressure: -1 to +25bar (-14.5 to +362psi)
* Maximum measuring range: 40m (131ft), 60m (197ft) for enhanced dynamics
* Accuracy: ±2mm
* K-band: 26GHz
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval

Benefits

* Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)
* Reliable non-contact measurement even for changing product and process conditions
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation
* Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
* Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
* World's easiest proof test concept for SIL and WHG saves time and cost

Specification 

item
value
Grade
Industrial
Warranty
1 Year
Customized support
OEM
Place of Origin
Germany
Brand Name
Endress+Hauser
Model Number
Micropilot FMR52
Material
PTFE
Mode
Radar measurement
Measuring Principle
Level radar
Characteristic / Application
Premium device for continuous non-contact level measurement, in which aggressive media are used as well as for highest hygiene
requirements (ASME BPE, USP Class VI);
Flush mounted, fully PTFE filled horn antenna
Specialities
Heartbeat Technology,
SIL 2 according to IEC 61508,
Bluetooth® commissioning,
Operation and maintenance SmartBlue App,
Safety and reliability with Multi-Echo Tracking,
HistoROM,
RFID TAG for easy identification
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART)
Bluetooth® wireless technology and App (optional)
Frequency
K-band (~26 GHz)
Accuracy
+/- 2 mm (0.08 in)
Ambient temperature
-50...+80 °C
(-58...+176 °F)
Process Temperature
-196...+200 °C
(-321...+392 °F)
Process Pressure / Max. Overpressure Limit
Vacuum...25 bar
(Vacuum...363 psi)
Main Wetted Parts
PTFE
Process Connection
Flange:
DN50...DN150
ASME 2"...6"
JIS 10K
Process connection hygienic
Tri-Clamp ISO2852
DIN11851
Max. Measurement Distance
Standard: 40 m (131 ft)
With advanced dynamics: 60 m (197 ft)
Communication
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Bluetooth® wireless technology
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex
Safety approvals
Overfill protection WHG
SIL
Design approvals
EN 10204-3.1
ASME B31.3
AD2000
Hygienic approvals
3A, EHEDG
CoC ASME-BPE
Marine approval
GL/ ABS/ LR/ BV/ DNV
Options
Display,
Customized parameterization,
Remote operation via SmartBlue App using Bluetooth®,
Gas-tight feed through,
PWIS free
Application limits
Maximum measuring range is dependent on the tank form and/or application
Ammoniacal gas phase:
FMR54 in stilling well
Strong build-up formation:
FMR54 with air purge
Custody transfer measurement:
FMR5xx


пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки

Обычно мы отправляем по DHL, UPS, FEDEX или TNT,

В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.