Overview
The standard sensor for highest demands in liquid level measurement.
Specs at a glance
* Accuracy
+/- 2 mm (0.08 in)
* Process temperature
XT: -196...+280 °C
(-321...+536 °F)
HT: -196...+450 °C
(-321...+842 °F)
* Process pressure / max. overpressure limit
Vacuum...160 bar
(Vacuum...2320 psi)
* Max. measurement distance
Standard: 40 m (131 ft)
With "Advanced dynamics": 70 m (230 ft)
* Main wetted parts
316L, Alloy C, PTFE, ceramic
+/- 2 mm (0.08 in)
* Process temperature
XT: -196...+280 °C
(-321...+536 °F)
HT: -196...+450 °C
(-321...+842 °F)
* Process pressure / max. overpressure limit
Vacuum...160 bar
(Vacuum...2320 psi)
* Max. measurement distance
Standard: 40 m (131 ft)
With "Advanced dynamics": 70 m (230 ft)
* Main wetted parts
316L, Alloy C, PTFE, ceramic
Application
Micropilot FMR51 for level measurement even under extreme process conditions like high temperature and high pressure in the oil & gas and chemical industry. The FMR51 free space radar offers maximum reliability due to an innovative and patented sensor-design.
Micropilot is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors. Remote access via SmartBlue app is available.
Horn antenna for level measurement even under extreme conditions.
* Process connections: Thread, Tri-Clamp or flange
* Temperature: -196 to +450°C (-321 to + 842°F)
* Pressure: -1 to +160bar (-14.5 to +2,320psi)
* Maximum measuring range: 40m (131ft), 70m (230ft) for enhanced dynamics
* Accuracy: ±2mm
* K-band: 26GHz
* International explosion protection certificates, overfill prevention WHG, SIL, marine approvals, 5-point linearity protocol
* Remote access with SmartBlue App via Bluetooth® is available
Micropilot is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors. Remote access via SmartBlue app is available.
Horn antenna for level measurement even under extreme conditions.
* Process connections: Thread, Tri-Clamp or flange
* Temperature: -196 to +450°C (-321 to + 842°F)
* Pressure: -1 to +160bar (-14.5 to +2,320psi)
* Maximum measuring range: 40m (131ft), 70m (230ft) for enhanced dynamics
* Accuracy: ±2mm
* K-band: 26GHz
* International explosion protection certificates, overfill prevention WHG, SIL, marine approvals, 5-point linearity protocol
* Remote access with SmartBlue App via Bluetooth® is available
Benefits
* Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation
* Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
* Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
* World's easiest proof test concept for SIL and WHG saves time and cost
* Highest safety due to double ceramic coupling and gas-tight feedthrough
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation
* Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
* Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
* World's easiest proof test concept for SIL and WHG saves time and cost
* Highest safety due to double ceramic coupling and gas-tight feedthrough
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Micropilot FMR51
|
Measuring Principle
|
Level radar
|
Characteristic / Application
|
Premium device for continuous non-contact level measurement of liquids, pastes and slurries even under extreme process conditions;
Horn antenna: 40...100 mm |
Specialities
|
Heartbeat Technology,
SIL 2 according to IEC 61508, Bluetooth® commissioning, Operation and maintenance SmartBlue App, Safety and reliability with Multi-Echo Tracking, HistoROM, RFID TAG for easy identification |
Supply / Communication
|
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART) Bluetooth® wireless technology and App (optional) |
Frequency
|
K-band (~26 GHz)
|
Accuracy
|
+/- 2 mm (0.08 in)
|
Ambient Temperature
|
-50...+80 °C
(-58...+176 °F) |
Process Temperature
|
XT: -196...+280 °C
(-321...+536 °F) HT: -196...+450 °C (-321...+842 °F) |
Process Pressure / max. Overpressure Limit
|
Vacuum...160 bar
(Vacuum...2320 psi) |
Main Wetted Parts
|
316L, Alloy C, PTFE, ceramic
|
Process Connection
|
Thread:
MNPT 1 1/2, R 1 1/2 Flange: DN50...DN150, ASME 2"...6", JIS 10K, 63K |
Process Connection Hygienic
|
Tri-Clamp ISO2852
|
Max. Measurement Distance
|
Standard: 40 m (131 ft)
With "Advanced dynamics": 70 m (230 ft) |
Communication
|
4...20 mA HART
PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology |
Certificates / Approvals
|
ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex
|
Safety Approvals
|
Overfill protection WHG
SIL |
Design Approvals
|
EN 10204-3.1
NACE MR0175, MR0103 ASME B31.3 AD2000 |
Marine Approval
|
GL/ ABS/ LR/ BV/ DNV
|
Options
|
Display,
Customized parameterization, Remote operation via SmartBlue App using Bluetooth®, Gas-tight feed through, Antenna Extension, PWIS free |
Application Limits
|
Maximum measuring range is dependent on the tank form and/or application
Ammoniacal gas phase: FMR54 in stilling well Strong build- up formation: FMR54 with air purge 316L or Alloy C non-resistant: FMR50, FMR52, FMR53 Hygiene requirements: FMR52, FMR53 Custody transfer measurement: FMR5xx |
пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.