Overview
Economical Ultrasonic flowmeter with integrated temperature measurement.
Specs at a glance
* Max. measurement error
Volume flow:
- ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
- ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)
* Measuring range
0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)
* Medium temperature range
0 to 150° (17.8 to 302 °F)
* Max. process pressure
PN 25 / ASME Cl. 150
* Wetted materials
Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105
Volume flow:
- ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s)
- ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s)
* Measuring range
0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min)
* Medium temperature range
0 to 150° (17.8 to 302 °F)
* Max. process pressure
PN 25 / ASME Cl. 150
* Wetted materials
Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105
Application
Measuring of demineralized water in utilities, for example in boiler condensate return lines, requires reliable devices. Prosonic Flow E 100 provides economical and accurate bidirectional flow measurement across all industries. With its integrated temperature measurement, Prosonic Flow E 100 proves to be a multivariable flowmeter for considerable additional value in your plant. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.
* The measuring principle is independent of pressure, density, temperature and conductivity
* Bidirectional measuring of demineralized water applications for utilities, e.g. boiler condensate return lines. Device properties:
* Accuracy up to ±0.5 % (flow) or acc. to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temp.)
* Process temperatures up to 150 °C (302 °F)
* Entire meter housing made of stainless steel
* 4-20 mA HART, pulse/frequency output
* Local display for reading and monitoring available
* Robust transmitter housing
* The measuring principle is independent of pressure, density, temperature and conductivity
* Bidirectional measuring of demineralized water applications for utilities, e.g. boiler condensate return lines. Device properties:
* Accuracy up to ±0.5 % (flow) or acc. to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temp.)
* Process temperatures up to 150 °C (302 °F)
* Entire meter housing made of stainless steel
* 4-20 mA HART, pulse/frequency output
* Local display for reading and monitoring available
* Robust transmitter housing
Benefits
* Long-term stability – reliable, robust sensor
* Reducing further measuring point – multivariable device
* Dependable flow measurement – high turndown (200:1)
* Time-saving local operation without additional software and hardware – integrated web server
* Extended calibration intervals – integrated device verification due to Heartbeat Technology
* Easy commissioning – brief parameter explanations
* Reducing further measuring point – multivariable device
* Dependable flow measurement – high turndown (200:1)
* Time-saving local operation without additional software and hardware – integrated web server
* Extended calibration intervals – integrated device verification due to Heartbeat Technology
* Easy commissioning – brief parameter explanations
Specification
item
|
value
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Prosonic Flow E100
|
Type
|
Ultrasonic flow meters
|
Product Headline
|
Economical Ultrasonic flowmeter with integrated temperature measurement.
Bidirectional measuring of demineralized water applications for Utilities, e.g. boiler condensate return lines. |
Sensor Features
|
Long-term stability – reliable, robust sensor. Reducing further measuring point – multivariable device. Dependable flow
measurement – high turndown (200:1). Measurement accuracy up to ±0.5 % (flow) or according to EN 1434 Cl. 2, ±2.0 °C (± 3.6 °F) (temperature). Process temperatures up to 150 °C (302 °F). Entire meter housing made of stainless steel. |
Transmitter Features
|
Time-saving local operation without additional software and hardware – integrated web server. Extended calibration intervals –
integrated device verification due to Heartbeat Technology. Easy commissioning – brief parameter explanations. 4-20 mA HART, pulse/frequency output. Local display for reading and monitoring available. Robust transmitter housing. |
Nominal Diameter Range
|
DN 50 to 150 (2"to 6")
|
Wetted Materials
|
Measuring tube: 1.4301 (F304)
Process Connection: 1.4571; 1.4404 (F316L); 1.0038 (S235JR); 1,4306 (F304L); 1.4307 (F304L); A105 |
Measured Variables
|
Volume flow, calculated mass flow, flow velocity, sound velocity, temperature
|
Max. Measurement Error
|
Volume flow:
- ± 0.5 % o.r. ± 0.02% o.f.s. for 0.5 to 10 m/s (1.6 to 33 ft/s) - ± 0.07 % o.f.s. for flow velocities < 0.5 m/s (1.64 ft/s) |
Measuring Range
|
0.025 to 5 m/s (0.02 to 16.4 ft/s)
0 to 6360 dm3/min (0 to 1680 gal/min) |
Max. Process Pressure
|
PN 25 / ASME Cl. 150
|
Medium Temperature Range
|
0 to 150° (17.8 to 302 °F)
|
Ambient Temperature Range
|
-20 to 60 °C (-4 to 140 °F)
|
Sensor Housing Material
|
Stainless steel
|
Transmitter Housing Material
|
Compact:
AlSi10Mg, coated Stainless steel, 1.4301 |
Degree Of Protection
|
Standard: IP66/67, Type 4X enclosure
With opened housing: IP20, Type 1 enclosure |
Display/Operation
|
4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible |
Outputs
|
4‐20 mA HART (active)
Pulse/frequency/switch output (passive) |
Inputs
|
None
|
Power Supply
|
DC 19.2 to 28.8 V
|
Hazardous Area Approvals
|
None
|
Product Safety
|
CE, C-Tick, EAC marking
|
Metrological Approvals And Certificates
|
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) Calibration according to EN 1434 Class 2 |
Pressure Approvals And Certificates
|
PED
|
Material Certificates
|
3.1 material
|
пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.