Overview
Endress+Hauser 8A5C Proline Promass A500 Coriolis Flowmeter is an accurate single-tube flowmeter for lowest flow rates, as remote version with up to 4 I/Os.
Specs at a glance
* Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³
* Measuring range
0 to 450 kg/h (0 to 16.54 lb/min)
* Medium temperature range
-50 to 205 °C (-58 to 401 °F)
* Max. process pressure
430.9 bar (6250 psi)
* Wetted materials
Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22
Field of application
The compact Promass A is ideal for continuous process control in very demanding applications. Its unique self-drainable single-tube system enables accurate easurement of liquids and gases at lowest flow rates and high pressure. With its innovative remote transmitter Promass A 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and compliant verification.
* Measuring principle operates independently of physical fluid properties such as viscosity or density
* Suitable for applications with smallest flow quantities in all industries
Device properties
* Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈")
* Process pressure up to 430.9 bar (6250 psi)
* Medium temperature up to +205 °C (+401 °F)
* Remote version with up to 4 I/Os
* Backlit display with touch control and WLAN access
* Standard cable between sensor and transmitter
Benefits
* Space-saving installation – compact, lightweight sensor
* Highest product quality – self-drainable measuring tube in all line sizes
* Optimum process safety – resistant to corrosive ambient conditions and internal clogging
* Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet
* Reduced complexity and variety – freely configurable I/O functionality
* Integrated verification – Heartbeat Technology
Specification
item | value |
Warranty | 1 Year |
Customized support | OEM |
Place of Origin | Swaziland |
Brand Name | Endress+Hauser |
Model Number | Proline Promass A500 |
Type | Coriolis meters, Coriolis flowmeter |
Measuring Principle | Coriolis |
Product Headline | Accurate single-tube flowmeter for lowest flow rates, as remote version with up to 4 I/Os. Suitable for applications with smallest flow quantities in all industries. |
Sensor Features | Space-saving installation – compact, lightweight sensor. Highest product quality – self-drainable measuring tube design in all line sizes. Optimum process safety – resistant to corrosive ambient conditions and internal clogging. Nominal diameter: DN 1 to 4 (¹⁄₂₄ to ¹⁄₈"). Process pressure up to 430.9 bar (6250 psi). Medium temperature up to +205 °C (+401 °F). |
Transmitter Features | Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter. |
Nominal Diameter Range | DN 1 to 4 (¹⁄₂₄ to ¹⁄₈") |
Wetted Materials | Measuring tube: stainless steel, 1.4435 (316/316L); Alloy C22 |
Measured Variables | Mass flow, density, temperature, volume flow, corrected volume flow, reference density |
Max. Measurement Error | Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.35 % Density (liquid): ±0.0005 g/cm³ |
Measuring Range | 0 to 450 kg/h (0 to 16.54 lb/min) |
Max. Process Pressure | 430.9 bar (6250 psi) |
Medium Temperature Range | -50 to 205 °C (-58 to 401 °F) |
Ambient Temperature Range | -40 to 60 °C (-40 to +140 °F) |
Sensor Housing Material | Stainless steel, 1.4404 (316L) |
Transmitter Housing Material | AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat |
Degree Of Protection | Sensor remote version (standard): IP66/67, type 4X enclosure Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure |
Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible |
Outputs | 4 outputs: 4-20 mA HART (active/passive) 4-20 mA WirelessHART 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output |
Inputs | Status input 4-20 mA input |
Digital Communication | HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, Profinet, Ethernet/IP, OPC-UA |
Power Supply | DC 24 V AC 100 to 230 V AC 100 to 230 V / DC 24 V (non-hazardous area) |
Hazardous Area Approvals | ATEX, IECEx, cCSAus, INMETRO, NEPSI |
Product Safety | CE, C-TICK |
Functional Safety | Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511 |
Metrological Approvals And Certificates | Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation) |
Hygienic Approvals And Certificates | 3-A, cGMP |
Pressure Approvals And Certificates | CRN |
Material Certificates | 3.1 material |