Overview
Highest performance pressure sensor with the Contite cell for hydrostatic level measurement.
Specs at a glance
* Accuracy
Standard 0.1%
Optional 0.075%
* Process temperature
-10°C...+100°C
(+14°F...+212°F)
* Pressure measuring range
100 mbar...10 bar
(1.5 psi...150 psi)
* Process pressure / max. overpressure limit
40 bar (600 psi)
* Main wetted parts
Alloy C
316L
* Max. measurement distance
100 m (328 ft) H2O
* Material process membrane
316L, AlloyC,
Gold-Rhodium
* Measuring cell
100 mbar...10 bar
(1.5 psi...150 psi)
Standard 0.1%
Optional 0.075%
* Process temperature
-10°C...+100°C
(+14°F...+212°F)
* Pressure measuring range
100 mbar...10 bar
(1.5 psi...150 psi)
* Process pressure / max. overpressure limit
40 bar (600 psi)
* Main wetted parts
Alloy C
316L
* Max. measurement distance
100 m (328 ft) H2O
* Material process membrane
316L, AlloyC,
Gold-Rhodium
* Measuring cell
100 mbar...10 bar
(1.5 psi...150 psi)
Field of application
The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters
easy. Designed according to IEC 61508 for use in SIL3 safety systems.
For level and/or pressure measurement.
* Process connections: Threads, flanges and hygienic connections
* Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
* Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)
* Accuracy: ±0.075%
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
easy. Designed according to IEC 61508 for use in SIL3 safety systems.
For level and/or pressure measurement.
* Process connections: Threads, flanges and hygienic connections
* Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
* Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)
* Accuracy: ±0.075%
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
Benefits
* Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation
* Best batch-to-batch repeatability and long-term stability
* Modular concept for easy replacement of display or electronics
* HistoROM/M-DAT data backup for instrument settings and measured values
* Function-monitored from the measuring cell to the electronics
* Seamless and independent system integration (HART/PA/FF)
* International usage thanks to a wide range of approvals
* Best batch-to-batch repeatability and long-term stability
* Modular concept for easy replacement of display or electronics
* HistoROM/M-DAT data backup for instrument settings and measured values
* Function-monitored from the measuring cell to the electronics
* Seamless and independent system integration (HART/PA/FF)
* International usage thanks to a wide range of approvals
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Deltapilot FMB70
|
Measuring Principle
|
Hydrostatic pressure
|
Characteristic
|
Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences Compact version |
Supply Voltage
|
4...20 mA HART
10,5...45 VDC (Non Ex): Ex ia: 10,5...30 VDC PROFIBUS PA: 9...32 VDC (Non Ex) FOUNDATION Fieldbus: 9...32 VDC (Non Ex) |
Reference Accuracy
|
Standard 0.1%
Optional 0.075% |
Long Term Stability
|
0.05 % of URL/year
|
Process Temperature
|
-10°C...100°C
(14°F...212°F) |
Ambient Temperature
|
-40°C...85°C
(-40°F...185°F) |
Measuring Cell
|
100 mbar...10 bar
(1.5 psi...150 psi) |
Smallest Calibratable Span
|
25 mbar (3.63 psi)
|
Vacuum Resistance
|
0 mbar abs.
|
Max. Overpressure Limit
|
40 bar (600 psi)
|
Process Connection
|
Thread:
G1 1/2, MNPT1 1/2 Flange: DN40...DN100, ASME 2"...4", JIS 10K |
Material Process Membrane
|
316L, AlloyC,
Gold-Rhodium |
Material Gasket
|
None, measuring cell welded
|
Fill Fluid
|
Inert oil,
Synthetic oil |
Material Housing
|
316L, Die-cast aluminum
|
Communication
|
4 ... 20 mA HART
PROFIBUS PA FOUNDATION Fieldbus |
Certificates / Approvals
|
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex
|
Safety Approvals
|
SIL
|
Design Approvals
|
EN10204-3.1
NACE MR0175 MR0103 |
Hygienic Approvals
|
3A, EHEDG
CoC ASME-BPE |
Marine Approvals
|
GL, DNV
|
Drinking Water Approvals
|
NSF
|
Specialities
|
Gold-rhodium coated membrane
|
пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.