Overview
For continuous level and interface measurement in liquids - for large measuring ranges.
Specs at a glance
* Accuracy
repeatablity 0,1%
* Process temperature
-80°C...200°C
-112°F...392°F
* Process pressure / max. overpressure limit
Vacuum ... 100 bar
(Vaccum ... 1450 psi)
* Max. measurement distance
0.42 m ... 10.0 m
(1.38 ft ... 33 ft)
* Main wetted parts
Insulation material: FEP,PFA, 316L
repeatablity 0,1%
* Process temperature
-80°C...200°C
-112°F...392°F
* Process pressure / max. overpressure limit
Vacuum ... 100 bar
(Vaccum ... 1450 psi)
* Max. measurement distance
0.42 m ... 10.0 m
(1.38 ft ... 33 ft)
* Main wetted parts
Insulation material: FEP,PFA, 316L
Application
Liquicap FMI52 is a reliable fully insulated rope probe for continuous level monitoring in liquids, particularly in small tanks,build-up forming media and extremely high temperatures - especially for large measuring ranges. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.
Device is independent of the dielectric constant (dc) as of a liquid conductivity of 100μS/cm and allows measurement of various liquids without the need for recalibration.
* Process connections: Flanges and threads
* Process pressure: Vacuum to +100bar (vacuum to 1,450psi)
* Measuring range: 0.42 to 10.0m (1.38 to 33ft)
* Temperature: -80 to +200°C (-112 to +392°F)
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
Device is independent of the dielectric constant (dc) as of a liquid conductivity of 100μS/cm and allows measurement of various liquids without the need for recalibration.
* Process connections: Flanges and threads
* Process pressure: Vacuum to +100bar (vacuum to 1,450psi)
* Measuring range: 0.42 to 10.0m (1.38 to 33ft)
* Temperature: -80 to +200°C (-112 to +392°F)
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals
Benefits
* Use also in safety systems requiring functional safety to SIL2 in accordance with IEC 61508
* Reliable and universal application thanks to wide range of certificates and approvals
* No calibration necessary (factory preconfiguration). No calibration necessary for media with a conductivity of 100μS/cm and higher
* Material in contact with the process made of corrosion-resistant material
* Menu-guided local configuration via plain text display (optional)
* Two-stage overvoltage protection
* Reliable and universal application thanks to wide range of certificates and approvals
* No calibration necessary (factory preconfiguration). No calibration necessary for media with a conductivity of 100μS/cm and higher
* Material in contact with the process made of corrosion-resistant material
* Menu-guided local configuration via plain text display (optional)
* Two-stage overvoltage protection
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Liquicap FMI52
|
Mode
|
Capacitance Level Measurement
|
Measuring Principle
|
Capacitive
|
Characteristic / Application
|
Fully insulated rope probe, for standard and extreme process conditions (temperature, pressure)
|
Interface Measurement
|
Interfaces liquid / liquid also with emulsion layers
|
Specialities
|
Inactive length
Factory calibrated short response time by change of value |
Supply / Communication
|
12-36V DC HART
PFM |
Accuracy
|
repeatablity 0,1%
|
Linearity Error For Conductive Liquids
|
<0,25%
|
Ambient Temperature
|
-50°C ... 70°C
(-58°F ... 158°F) |
Process Temperature
|
-80°C...200°C
-112°F...392°F |
Process Pressure / Max. Overpressure Limit
|
Vacuum ... 100 bar
(Vaccum ... 1450 psi) |
Main Wetted Parts
|
Insulation material: FEP,PFA
316L |
Process Connection
|
G 3/4, G 1, G1 1/2 /NPT 3/4", NPT 1, NPT1 1/2"
Flange from DN25.../ASME 1".../JIS... |
Process Connection Hygienic
|
Tri-Clamp ISO02852 gap free plated
Dairy coupling Flush-mounted seal |
Sensor Length
|
Total length: 6m (20ft)
Inactive length: max. 2m (7ft) |
Max. Measurement Distance
|
0.42 m ... 10.0 m
(1.38 ft ... 33 ft) |
Communication
|
4...20mA HART
PFM |
Certificates / Approvals
|
ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC
|
Safety Approvals
|
SIL
|
Design Approvals
|
EN 10204-3.1
NACE MR0175 |
Hygienic Approvals
|
EHEDG
|
Marine Approval
|
GL/ ABS/ DNV
|
Options
|
Separate housing
gas-tight probe seal |
Application Limits
|
Changing, non-conductive
media, conductivity < 100 μS/cm Notice the pressure and temperature derating |
пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.