Endress+Hauser TAF11 High temperature TC thermometer

: В наличии

: Temperature Meaurement

: Endress+Hauser

Обычная цена Распродажа

Overview Applicable for steel treatment (annealing), concrete furnaces and primaries. Specs at a glanceAccuracyclass 2 acc. to IEC 60584Max. process pressure (static)at 20 °C: 1 bar (15 psi)Operating...

Overview

Applicable for steel treatment (annealing), concrete furnaces and primaries.

Specs at a glance
Accuracy
class 2 acc. to IEC 60584
Max. process pressure (static)
at 20 °C: 1 bar (15 psi)
Operating temperature range
Type K:
-40 °C ...1.300 °C
(-40 °F ...2.372 °F)
Type J:
-40 °C ...750 °C
(-40 °F ...1.382 °F)
Type N:
-40 °C ...1.150 °C
(-40 °F ...2102 °F)
Type S:
0 °C ...1.600 °C
(32 °F ...2.912 °F)
Type R:
0 °C ...1.600 °C
(32 °F ...2.912 °F)
Type B:
600 °C ...1.600 °C
(1.112 °F ...2.912 °F)
Max. immersion length on request
up to 4.000,00 mm (157,48'')


Field of application


Measuring points with extremely high process temperatures require these special thermometers with ceramic thermowells and thermocouples made from special metals, such as platinum and rhodium. The thermowell made from special materials serves as protection from mechanical and chemical damages in the process and increases the life span of the used sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

* Applicable for steel treatment (annealing), concrete furnaces and primaries. It contains a single or double TC insert and a ceramic protection tube.
* Process temperatures: up to +1600 °C (+2912 °F)

Benefits


* Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance
* Long term stable measurement due to sensor protection with non-porous materials
* Flexible product selection by modular design
* Optimized life cycle costs by means of replaceable spare parts

Specification


Brand Name
ENDRESS+HAUSER
Model Number
TAF11
Theory
Temperature Transmitter
Material
Ceramic (C610) silicon nitride ceramic (SiN) sintered silicon carbide (SiC)
Accuracy
class 2 acc. to IEC 60584
Max. immersion length on request
up to 4.000,00 mm (157,48'')
Process temperatures
up to +1600 °C (+2912 °F)
Measuring principle
Thermocouple
Characteristic / Application
metric style
modular temperature assembly
high temperature probe (furnace)
incl. single ceramic thermowell
Thermowell / protection tube
ceramic protection tube
Insert / probe
ceramic capilarry, rigid
Outer diameter protection tube / Insert
14,0 mm (0,55")
16,0 mm (0,59")
17,0 mm (0,68")
22,0 mm (0,87")
24,0 mm (0,94")
26,6 mm (1,05")
Material protection tube/ thermowell
Ceramic (C610)
silicon nitride ceramic (SiN)
sintered silicon carbide (SiC)
Process connection
compression fitting:
G3/4"
G1"
G11/2"
adjustable Flange
Tip shape
straight
Operating temperature range
Type K:
-40 °C ...1.300 °C
(-40 °F ...2.372 °F)
Type J:
-40 °C ...750 °C
(-40 °F ...1.382 °F)
Type N:
-40 °C ...1.150 °C
(-40 °F ...2102 °F)
Type S:
0 °C ...1.600 °C
(32 °F ...2.912 °F)
Type R:
0 °C ...1.600 °C
(32 °F ...2.912 °F)
Type B:
600 °C ...1.600 °C
(1.112 °F ...2.912 °F)
Max. process pressure (static)
at 20 °C: 1 bar (15 psi)
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Certification
SIL (transmitter only)


пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки

Обычно мы отправляем по DHL, UPS, FEDEX или TNT,

В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.