Endress+Hauser Ultrasonic Measurement Time-of-Flight Prosonic FMU41

: В наличии

: Level Measurement

: Endress+Hauser

Обычная цена Распродажа

Overview Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 8m Specs at a glance * Accuracy+/- 2 mm or +/- 0,2...



Overview

Cost effective device for sophisticated level measurement in liquids and bulk solids for up to 8m

Specs at a glance
* Accuracy
+/- 2 mm or +/- 0,2 % of set measuring range
* Process temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)
* Process pressure / max. overpressure limit
0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
* Max. measurement distance
Liquids: 8 m (26 ft),
Solids: 3.5 m (11 ft)
* Main wetted parts
PVDF

Application

The Prosonic FMU41 sensor is suited for non-contact level measurement in fluids, pastes, coarse bulk material and flow measurement in open channels or at weirs. The two-wire or four-wire compact transmitter can be used in applications with storage tanks,agitators, on stockpiles and conveyor belts. The envelope curve can be shown on the on-site display for simple diagnosis.Linearization function (up to 32 points) for conversion of the measured value into any unit of length, volume or flow rate.
Two-wire or four wire instrument for continuous non-contact level and flow measurement.
* Process connection: Thread
* Temperature: -40 to +80°C (-40 to +176°F)
* Pressure: +0.7 to +3bar (+10 to +44psi)
* Maximum measuring distance: Liquids 8m (26ft), Solids 3.5m (11ft)
* Blocking distance: Liquids and Solids 0.35m (1.15ft)
* International explosion protection certificates

Benefits

* Reliable non-contact measurement
* Quick and simple commissioning via menu-guided on-site operation with four-line plain text display, 7 languages selectable
* Envelope curves on the on-site display for simple diagnosis
* Hermetically sealed and potted sensor
* Chemically resistant sensor out of PVDF
* Calibration without filling or discharging
* Integrated temperature sensor for automatic correction of the temperature dependent sound velocity

Specification

item
value
Grade
Industrial
Warranty
1 Year
Customized support
OEM
Place of Origin
Germany
Brand Name
endress+hauser
Model Number
Prosonic FMU41
Material
PVDF
Mode
Ultrasonic measurement Time-of-Flight
Measuring Principle
Ultrasonic
Characteristic / Application
Compact ultrasonic transmitter
Supply / Communication
2-wire HART
Accuracy
+/- 2 mm or +/- 0,2 % of set measuring range
Ambient Temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)
Process Temperature
-40 °C ... 80 °C
(-40 °F ... 176 °F)
Process Pressure / Max. Overpressure Limit
0.7 bar ... 3 bar abs
(10 psi ... 44 psi)
Main Wetted Parts
PVDF
Process Connection
G / NPT 2"
Blocking Distance
0.35 m (1.15 ft)
Max. Measurement Distance
Liquids: 8 m (26 ft),
Solids: 3.5 m (11 ft)
Communication
4...20 mA HART
Certificates / Approvals
ATEX, FM, CSA, TIIS, INMETRO, NEPSI
Application Limits
For higher resistance:
FMU42/FDU9x
Foam / high turbulence possible:
FMU42/FDU91
Fast filling and discharging rate:
FMU90 + FDU9x
Level limit detection:
FMU90 + FDU9x

пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки

Обычно мы отправляем по DHL, UPS, FEDEX или TNT,

В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.