Overview
Economically efficient basis model for level measurement in solids.
Specs at a glance
* Accuracy
+/- 3 mm (0.12 in)
* Process temperature
-40 °C...+80 °C
(-40 °F...+176 °F)
* Process pressure / max. overpressure limit
Vacuum...3 bar
(Vacuum...43.5 psi)
* Max. measurement distance
30 m (98 ft)
* Main wetted parts
PP, UP
+/- 3 mm (0.12 in)
* Process temperature
-40 °C...+80 °C
(-40 °F...+176 °F)
* Process pressure / max. overpressure limit
Vacuum...3 bar
(Vacuum...43.5 psi)
* Max. measurement distance
30 m (98 ft)
* Main wetted parts
PP, UP
Application
Micropilot FMR56 is particularly designed for light-duty process conditions as they occur in silos or bins for solids. Micropilot free space radar is used for continuous,
non-contact level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement.
PP-plated horn antenna can be easily aligned to the surface of the solids by the mounting bracket or a turnable seal.
* Process connections: Mounting bracket or slip-on flange
* Temperature: -40 to +80°C (-40 to +176°F)
* Pressure: -1 to +3bar (-14.5 to +43.5psi)
* Maximum measuring range: 30m (98ft)
* K-band: 26GHz
* International explosion protection certificates, SIL, 5-point linearity protocol
non-contact level measurement in powdery to granular bulk solids. Dust, filling noises, temperature layers and gas layers do not affect the measurement.
PP-plated horn antenna can be easily aligned to the surface of the solids by the mounting bracket or a turnable seal.
* Process connections: Mounting bracket or slip-on flange
* Temperature: -40 to +80°C (-40 to +176°F)
* Pressure: -1 to +3bar (-14.5 to +43.5psi)
* Maximum measuring range: 30m (98ft)
* K-band: 26GHz
* International explosion protection certificates, SIL, 5-point linearity protocol
Benefits
* Reliable measurement even for changing product and process conditions
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation
* Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)
* Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
* Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
* World's easiest proof test concept for SIL and WHG saves time and cost
* HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
* Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation
* Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)
* Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
* Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
* World's easiest proof test concept for SIL and WHG saves time and cost
Specification
item
|
value
|
Grade
|
Industrial
|
Warranty
|
1 Year
|
Customized support
|
OEM
|
Place of Origin
|
Germany
|
Brand Name
|
Endress+Hauser
|
Model Number
|
Micropilot FMR56
|
Measuring Principle
|
Level radar
|
Characteristic / Application
|
For simple applications:
Reliable non-contact level measurements in silos or storage tanks for bulk solids |
Specialities
|
Heartbeat Technology,
Bluetooth® commissioning, Operation and maintenance SmartBlue App, Safety and reliability with Multi- Echo Tracking, HistoROM, RFID TAG for easy identification, |
Supply / Communication
|
2-wire (HART/ PROFIBUS PA/ FOUNDATION Fieldbus)
4-wire (HART) Bluetooth® wireless technology and App (optional) |
Frequency
|
K-band (~26 GHz)
|
Antenna
|
Horn DN80/3", PP plated
Horn DN100/4", PP plated |
Accuracy
|
+/- 3 mm (0.12 in)
|
Ambient Temperature
|
-40 °C...+80 °C
(-40 °F...+176 °F) |
Process Temperature
|
-40 °C...+80 °C
(-40 °F...+176 °F) |
Process Pressure / max. Overpressure Limit
|
Vacuum...3 bar
(Vacuum...43.5 psi) |
Main Wetted Parts
|
PP, UP
|
Process Connection
|
Flange:
UNI DN80...DN150 (3"...6") Mounting bracket |
Max. Measurement Distance
|
30 m (98 ft)
|
Communication
|
4...20 mA HART
PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology |
Certificates / Approvals
|
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC Ex, KC, UK Ex
|
Safety Approvals
|
SIL
|
Options
|
Display,
Customized parameterization Remote operation via SmartBlue App using Bluetooth® |
Application Limits
|
DK < 1.6
Reduction of the max. possible measuring range through: Media with poor reflection properties Angle of repose Extremely loose surfaces of bulk solids, e.g. bulk solids with low bulk weight for pneumatic filling Build-up, above all of moist products |
пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.
Обычно мы отправляем по DHL, UPS, FEDEX или TNT,
В некоторые страны невозможно отправить товар указанным выше способом, тогда мы будем использовать линию EMS или Country Logistics.