Endress+Hauser Hydrostatic Level Measurement Deltapilot FMB70

: В наличии

: Level Measurement

: Endress+Hauser

Обычная цена Распродажа

Overview Highest performance pressure sensor with the Contite cell for hydrostatic level measurement. Specs at a glance * AccuracyStandard 0.1%Optional 0.075%* Process temperature-10°C...+100°C(+14°F...+212°F)* Pressure measuring range100 mbar...10 bar(1.5...

Overview

Highest performance pressure sensor with the Contite cell for hydrostatic level measurement.
Specs at a glance
* Accuracy
Standard 0.1%
Optional 0.075%
* Process temperature
-10°C...+100°C
(+14°F...+212°F)
* Pressure measuring range
100 mbar...10 bar
(1.5 psi...150 psi)
* Process pressure / max. overpressure limit
40 bar (600 psi)
* Main wetted parts
Alloy C
316L
* Max. measurement distance
100 m (328 ft) H2O
* Material process membrane
316L, AlloyC,
Gold-Rhodium
* Measuring cell
100 mbar...10 bar
(1.5 psi...150 psi)

Field of application

The Deltapilot FMB70 with the condensate resistant Contite measuring cell and two-chamber housing is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. The integrated HistoROM/M-DAT data module makes management of process and device parameters
easy. Designed according to IEC 61508 for use in SIL3 safety systems.
For level and/or pressure measurement.
* Process connections: Threads, flanges and hygienic connections
* Temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
* Measuring range: 0.1 to 10 bar rel. (1.5 to 150 psi)
* Accuracy: ±0.075%
* International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approvals

Benefits

 * Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.1%, optionally ±0.075% and minimum temperature effects thanks to active temperature compensation
* Best batch-to-batch repeatability and long-term stability
* Modular concept for easy replacement of display or electronics
* HistoROM/M-DAT data backup for instrument settings and measured values
* Function-monitored from the measuring cell to the electronics
* Seamless and independent system integration (HART/PA/FF)
* International usage thanks to a wide range of approvals

Specification

item
value
Grade
Industrial
Warranty
1 Year
Customized support
OEM
Place of Origin
Germany
Brand Name
Endress+Hauser
Model Number
Deltapilot FMB70
Measuring Principle
Hydrostatic pressure
Characteristic
Pressure transmitter for hydrostatic level measurement with flush mounted metallic Contite measuring cell:
Hermetically sealed, condensate-resistant, climatic-proofed and with lowest temperature influences
Compact version
Supply Voltage
4...20 mA HART
10,5...45 VDC (Non Ex):
Ex ia: 10,5...30 VDC
PROFIBUS PA:
9...32 VDC (Non Ex)
FOUNDATION Fieldbus:
9...32 VDC (Non Ex)
Reference Accuracy
Standard 0.1%
Optional 0.075%
Long Term Stability
0.05 % of URL/year
Process Temperature
-10°C...100°C
(14°F...212°F)
Ambient Temperature
-40°C...85°C
(-40°F...185°F)
Measuring Cell
100 mbar...10 bar
(1.5 psi...150 psi)
Smallest Calibratable Span
25 mbar (3.63 psi)
Vacuum Resistance
0 mbar abs.
Max. Overpressure Limit
40 bar (600 psi)
Process Connection
Thread:
G1 1/2, MNPT1 1/2
Flange:
DN40...DN100,
ASME 2"...4",
JIS 10K
Material Process Membrane
316L, AlloyC,
Gold-Rhodium
Material Gasket
None, measuring cell welded
Fill Fluid
Inert oil,
Synthetic oil
Material Housing
316L, Die-cast aluminum
Communication
4 ... 20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals
ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI, EAC, UK Ex
Safety Approvals
SIL
Design Approvals
EN10204-3.1
NACE MR0175
MR0103
Hygienic Approvals
3A, EHEDG
CoC ASME-BPE
Marine Approvals
GL, DNV
Drinking Water Approvals
NSF
Specialities
Gold-rhodium coated membrane
пожалуйста, свяжитесь по электронной почте для получения дополнительной информации о стоимости доставки

Обычно мы отправляем по DHL, UPS, FEDEX или TNT,